Skip to main content

Detection of G119S ace-1 R mutation in field-collected Anopheles gambiae mosquitoes using allele-specific loop-mediated isothermal amplification (AS-LAMP) method

Abstract

Background

Malaria vectors have developed resistance to the four families of insecticides available for public health purposes. For example, the kdr mutation is associated with organochlorines and pyrethroids resistance. It is of particular concern that organophosphate and carbamate resistance associated with the G119S ace-1 R mutation has recently increased in West Africa in extent and frequency, and is now spreading through the Anopheles gambiae malaria vector population. There is an urgent need to improve resistance management using existing insecticides and new tools to quickly assess resistance level for rapid decision-making.

Methods

DNA extracted from field-collected mosquitoes was used to develop the method. Specific primers were designed manually to match the mutation region and an additional mismatched nucleotide in the penultimate position to increase specificity. Other primers used are common to both wild and mutant types. The allele specific (AS)-LAMP method was compared to the PCR restriction fragment length polymorphism (PCR-RFLP) and real-time PCR (RT-PCR) methods using the genomic DNA of 104 field-collected mosquitoes.

Results

The primers designed for LAMP were able to distinguish between the wild type (ace-1 S) and mutated type allele (ace-1 R). Detection time was 50 min for the wild type homozygous and 64 min for the heterozygous. No amplification of the resistant allele took place within the 75-min test period when using the wild type primers. For the ace-1 R resistant type, detection time was 51 min for the resistant homozygous and 55 min for the heterozygous. No amplification of the wild type allele took place within the 75-min test period when using the resistant type primers. Gel electrophoresis of LAMP products confirmed that amplification was primer-DNA specific, i.e., primers could only amplify their target specific DNA. AS-LAMP, PCR-RFLP, and RT-PCR showed no significant difference in the sensitivity and specificity of their ace-1 R detection ability.

Conclusions

The AS-LAMP method could detect the ace-1 R mutation within 60 min, which is faster than conventional PCR-RFLP. This method may be used to quickly detect the ace-1 R mutation for rapid decision-making, even in less well-equipped laboratories.

Background

Recent statistics have revealed worldwide reductions in malaria-related mortality and morbidity, attributable to vector control measures [1]. Although a fair amount of progress has been made on malaria vaccine trials [2], disease prevention remains heavily dependent on insecticide-treated bed nets and indoor residual spraying with insecticides [3].

The resistance of malaria vectors to insecticide is the main concern in vector control interventions. In recent years, resistance to the four classes of insecticides available for public health use has increased across Burkina Faso [46]. Resistance to pyrethroid, organophosphates and carbamates has spread in tandem with the increased incidence of the L1014F kdr and G119S ace-1 R mutations [4, 7]. Recent studies also suggest the importance of metabolic mechanisms in high-level pyrethroid resistance in Burkina Faso [8, 9]. In the case of the ace-1 R gene, a single substitution of the amino acid glycine with serine in position 119 (G119S) of this acetylcholinesterase gene is linked to resistance to carbamates and organophosphates insecticides [10]. Furthermore, it has also been reported that the duplication of ace-1 gene in Anopheles gambiae (and also Culex) contributes to insecticide resistance [1113].

The latter insecticide families are the only ones still effective against malaria vectors in Burkina Faso [5]. However, molecular investigations have recently confirmed an increase in ace-1 R mutations in the population of An. gambiae, with an unequal distribution from the western part of the country to the central part, where the mutation still has a very low frequency [4, 14].

The new challenges for malaria control are related to the monitoring of resistance to insecticides, with the goal of better allocating resources for malaria vector control and management of resistance [15]. According to the malERA Consultative Group [16], a related and critical focus of the vector control agenda will be the development of rapid and affordable methods for detecting the emergence of epidemiologically important levels of insecticide resistance. Very relevant in this regard is adapting or developing early resistance detection tools, among which the LAMP (loop-mediated isothermal amplification) method is recognized as a more sensitive and specific method than conventional PCR approaches [1722].

LAMP has recently been employed to identify the two species of the An. gambiae complex [23]. Badolo et al. [24] have developed a single nucleotide polymorphism (SNP)-LAMP method to target the L1014F mutation in field-collected mosquitoes. Based on these previous studies, a LAMP-based detection method for the ace-1 R mutation in field-collected An. gambiae complex is developed herein.

Methods

Primer design for LAMP detection of G119S ace-1 R mutation in mosquitoes

Allele-specific LAMP (AS-LAMP) primers were designed based on published sequences of the acetylcholinesterase gene carrying the ace-1 R mutation [10]. To detect the mutant and wild type of ace-1 R, the specific forward inner primer (FIP) and backward inner primer (BIP) were constructed with the mutation on the 5′ end. An additional mismatched nucleotide was added at the penultimate position of each specific BIP to increase the specificity of the primers to each targeted nucleotide site (Fig. 1). For primer mismatch optimization, DNA fragments from An. gambiae mosquitoes carrying either sensitive or resistance-type ace-1 genes were used as the template DNA of the LAMP reaction. The outer primers (B3 and F3) were identical for the two primer sets.

Fig. 1
figure 1

DNA sequence of the acetylcholinesterase gene surrounding the ace-1 R mutation and position of the LAMP primers designed for this study. The mutation nucleotide is bolded, G for the wild type (ace-1 S) and A for the resistant type (ace-1 R). Lower-case letters in BA8 and BA9 show additional mismatch

Mosquito collection

All mosquitoes used in this study were collected during the rainy season of 2008 in the village of Soumousso (N 11°00, W 04°03) located in the Sudan Savannah zone, 380 km from Ouagadougou and 38 km from Bobo-Dioulasso. The village is located within the cotton belt, where insecticide pressure is higher than in other parts of the country, as is the frequency of ace-1 R [4]. Mosquitoes were collected as larvae and reared to adults for morphological classification of species and sex. Only the female An. gambiae complex mosquitoes were used for analysis. The mosquitoes were kept in silica gel containing tubes until used.

Extraction of DNA from field-collected mosquitoes

The genomic DNA of field-collected mosquitoes was extracted by homogenizing individual mosquitoes with a pellet pestle in 100 µl Buffer A [0.1 M Tris HCl (pH 9.0), 0.1 M EDTA, 1 % SDS, and 0.5 % diethyl pyrocarbonate] and incubating the homogenate for 30 min at 70 °C. After incubation, 22.4 µl of 5 M potassium acetate was added, and the mixture was cooled on ice for 30 min. After centrifugation at 15,000 rpm for 15 min at 4 °C, the DNA-containing supernatant was transferred into a new tube and mixed with 45 µl isopropanol. The solution was centrifuged at 15,000 rpm for 20 min at 4 °C, and the supernatant was discarded. The DNA pellet was rinsed with 70 % ethanol and dried. The pellet was then diluted in 30 µl TE buffer.

LAMP reaction procedure

The LAMP reaction was carried out following manufacturer recommendations (Eiken Chemicals, Tokyo, Japan). A master mix was prepared using 6.25 µl of 2× reaction mix (2.8 mM each of dNTP, 40 mM Tris–HCl (pH 8.8), 20 mM KCl, 16 mM MgSO4, 20 mM (NH4)2SO4, 0.2 % Tween 20, and 1.6 M betain), 2.75 µl of distilled water and 0.5 µl of each of the primers and the Bst DNA polymerase. The concentration of the primers used was 40 pmol/µl for the inner primers (BIP and FIP) and 5 pmol/µl for the outer primers (B3 and F3). A volume of 11.5 µl of the master mix was placed into test tubes (including a negative control). One µl of DNA solution was added to the sample tubes and 1 µl of distilled water to the negative control tube. All procedures were carried out on ice. The tubes were then incubated in a water bath or LA-200 real-time turbidimeter (Eiken Chemicals) at 63 °C, and turbidity was measured. The reaction was terminated by heating the tube at 95 °C for 5 min. A 2 % agarose gel electrophoresis at 100 V of the LAMP products was performed and the gel was stained with ethidium bromide for examination under UV light to check amplification bands.

PCR-RFLP for ace-1 R mutation detection

The MR4 protocol [25] (based on Weil et al. [10]) was used for ace-1 R mutation detection method by PCR-RFLP analysis. The ace-1 R SNP region was amplified with two primers (MOUSTDIR1:) (25 pmol/μl) [CCGGGNGCSACYATGTGGAA] MOUSTREV1 (25 pmol/μl) [ACGATMACGTTCTCYTCCGA]. PCR was carried out in a 25-µl tube using KOD FX Neo DNA polymerase (Toyobo, Osaka, Japan). Amplification was performed with 1 µl of genomic DNA as the template using the following PCR programme: 94 °C/2 min × 1 cycle, (98 °C/10 s, 68 °C/30 s) × 35 cycles, 68 °C/2 min × 1 cycle, and 4 °C hold. The PCR product was digested by adding 1 μl AluI (New England Biolabs, Ipswich, MA, USA) restriction enzyme, 2 μl of H20, and 2 μl of buffer to 15 μl. An incubation at 37 °C for 8–24 h [25] was observed. Finally, 5 µl of the digestion product was run on 2 % agarose gel and stained in ethidium bromide.

Real-time PCR (RT-PCR) detection of the ace-1 R mutation

RT-PCR detection of ace-1 R was carried out based on the methods in the Anopheles Research protocol [25, 26], with the primers (forward: GCCGTCATGCTGTGGATCTT, reverse: GCCCGGTGGTCGTACAC) and probes (wild type allele: VIC-CGGCGGCTTCTAC, mutant type allele: FAM-CGGCAGCTTCTAC) with TaqMan GTXpress master mix (Life Technologies, Carlsbad, CA, USA) and analysed by StepOne RT-PCR machine (Life Technologies). For the positive controls, DNA fragments from An. gambiae mosquitoes carrying either sensitive or resistance-type ace-1 genes cloned into pBSSK vectors were used. PCR alignment scores were taken from respective endpoint scatter plots.

Sequencing of mosquito DNA

DNA from An. gambiae mosquitoes was used as PCR templates. The target sequence was amplified using the PCR primers BA3 (GCTGGTGGTCAACACGGATA) and BA4 (CCCAGCTGACTCCCAAGAAG), designed to amplify a 603-bp DNA fragment of ace-1 including its SNP region. PCR was performed in a tube with KOD FX Neo DNA polymerase (0.5 µl). The PCR programme was 94 °C/2 min × 1 cycle, (98 °C/10 s, 68 °C/30 s) × 35 cycles, 68 °C/2 min × 1 cycle, and 4 °C hold. The PCR product was purified using a geneclean kit (MP Biomedicals, Santa Ana, CA, USA) and the final product was diluted in 10 µl of distilled water. The nucleotide sequences were determined with a BigDye terminator sequencing kit v. 3.1 (Life Technologies, Carlsbad, CA, USA) using an automated 3100 genetic analyzer (Life Technologies).

Statistical analysis

Sensitivity was defined as the ratio of true positives to combined true and false positives, and specificity as the ratio of true negatives to combined true negatives and false negatives. Calculation of specificity and sensitivity confidence limits of AS-LAMP and RT-PCR was carried out using the Wilson score method [27].

Results

Primer sequences

The BIP and FIP primers, containing the SNP with an additional mismatched nucleotide attached to the penultimate nucleotide at the 3′ (BIP) or 5′ end (FIP), were designed as specific primers to detect the G119S single nucleotide by AS-LAMP. The two specific primers and the mismatched nucleotide increase the specificity of both primers for their target DNA. The different regions targeted by the primers and the primer sequences are shown in Fig. 1.

Detection of the ace-1 R mutation by AS-LAMP using genomic mosquito DNA

The primers designed for AS-LAMP were able to distinguish between the wild type allele (ace-1 S) and the mutated type allele (ace-1 R). Detection time for the wild type mutation was ~ 50 min after incubation in the turbidimeter using the wild type primers; detection time for heterozygous samples was 64 min using the same primers. Using these primers, no amplification of the resistant allele (ace-1 R) took place within the 75-min test period (Fig. 2a).

Fig. 2
figure 2

Wild type (ace-1 S) mutation detection using ace-1 S specific primers and mosquito genomic DNA. Amplification graph (a), gel electrophoresis (b) and naked eye detection (c) using wild type primers against negative control (D.W. distilled water), SS wild type homozygous DNA, RS heterozygous, RR ace-1 R type homozygous, L DNA ladder

For ace-1 R resistant type mutation detection, amplification started at ~51 min after incubation for resistant homozygous samples and at ~55 min for heterozygous samples, with no amplification of the wild type (ace-1 S) taking place within the 75-min test period when using the resistant type primers (Fig. 3a). Gel electrophoresis of the LAMP products confirmed that the amplification was primer DNA-specific, i.e., the primers could only amplify their target-specific DNA (Figs. 2b, 3b).

Fig. 3
figure 3

Mutant type (ace-1 R) mutation detection using ace-1 R specific primers and mosquito genomic DNA. Amplification graph (a), gel electrophoresis (b) and naked eye detection (c) using ace-1 R type primers against negative control (D.W. distilled water), SS wild type homozygous DNA, RS heterozygous, RR ace-1 R type homozygous, L DNA ladder

PCR-RFLP and real-time RT-PCR identification of the ace-1 R mutation

PCR-RFLP detection based on the protocol of Weill et al. [10] was used to detect the ace-1 R mutation in 104 field-collected mosquitoes. Three homozygous resistant samples, nine heterozygous samples and 95 sensitive homozygous samples were identified.

RT-PCR detection of ace-1 R, based on the methods in the Anopheles Research protocol [25], found 12 heterozygous samples and 92 homozygous samples for the sensitive alleles, while failing to clearly distinguish between any of the homozygous versus heterozygous samples (Fig. 4; Table 1).

Fig. 4
figure 4

RT-PCR identification of the ace-1 R mutation. Scatter plots of the fluorescence of ace-1 R mutation detection. Sequence SS the DNA samples identified as sensitive homozygous by the sequencing method, sequence RS identified as heterozygous, sequence RR identified as resistant homozygous, SS control the plasmid coding the ace-1 S sequence, RS control mixture of the plasmid coding the ace-1 S sequence and that coding the ace-1 R sequence, RR control the plasmid coding the ace-1 R sequence, negative control distilled water instead of template DNA

Table 1 Comparing the detection of the ace-1 R mutation using AS-LAMP and PCR-RFLP

Sensitivity and specificity of PCR-RFLP, RT-PCR and AS-LAMP methods relative to sequencing

To investigate the comparative sensitivity for detecting each genotype of the ace-1 R mutation, ace-1 R mutation detection using the AS-LAMP, PCR-RFLP and RT-PCR methods for 104 mosquitoes was performed. The samples were sequenced first using standard PCR (Table 1): these sequences were treated as the ‘gold standard’ for identification. The same samples were then analysed using AS-LAMP, PCR-RFLP and RT-PCR, and the respective results were compared against the corresponding standard PCR-derived sequence. AS-LAMP and PCR-RFLP had the same sensitivity for the homozygous resistant type [100 %, confidence limit (CL) 21–100 %], while RT-PCR could not distinguish clearly any resistant specimen (Fig. 4). For detection sensitivity of the heterozygous type, there was no statistically significant difference between AS-LAMP (89 %, CL 56–99 %), PCR-RFLP (100 %, CL 79–100 %), and RT-PCR (75 %, CL 47–91 %), although the sample number may have been too few to detect significance. The specificity of all three methods was perfect (100 %) for resistant homozygous and heterozygous detection. There were, however, slight (albeit not statistically significant) differences in detection specificity for the sensitive homozygous type (PCR-RFLP and AS-LAMP 90 %, CL 60–98 %; RT-PCR 100 %, CL 72–100 %).

AS-LAMP method detection using water bath and naked eye detection

To evaluate whether the AS-LAMP reaction could be done with only a water bath and scored by eye, without a real-time turbidimeter, 24 DNA samples used in Table 1 were randomly chosen and subjected to AS-LAMP with a water bath. As shown in Table 2, the naked eye detection results of all samples were completely identical to that obtained with the real-time turbidimeter.

Table 2 Comparison of the result of AS-LAMP method using water bath and naked eye detection with real-time turbidimeter

Discussion

Resistance to the four classes of insecticide available for public health use (organochlorines, organophosphates, carbamates, and pyrethroids) has been found in Anopheles species in different parts of Africa [2830]. This resistance may negatively impact the efficacy of insecticide-treated bed nets (ITNs) and indoor residual spraying (IRS) [31]. As no other classes of insecticides are available at this time, managing current insecticides seems to be the key solution to vector control.

Developing easy-to-use tools to detect epidemiologically significant resistant levels is a prerequisite for vector control [15]. A more sensitive and specific method that can be used with minimum equipment can facilitate decision-making on insecticide use.

In the present study, an AS-LAMP method targeting the ace-1 R mutation, which is involved in resistance to carbamates and organophosphates in An. gambiae malaria vectors, was developed. Primers designed with a mutation on the 3′ end of the BIP primer and an additional mismatched nucleotide (following Badolo et al. [24]) were unable to distinguish between the ace-1 S and ace-1 R mutation. The sequence of the acetylcholinesterase gene on which used was rich in GC and impeded the designing of suitable primers. Specificity to distinguish between ace-1 S and ace-1 R increased when the mutations were appended to the two inner primers.

Primers were able to detect heterozygous samples in less than 64 min, and the detection method proved to be as sensitive as and of comparable specificity to PCR-RFLP, although the tests of sensitivity were underpowered because the number of individuals with resistant alleles was very low. Identification of the ace-1 R mutation using the AS-LAMP method has several advantages. Since the LAMP method can be performed with only a water bath and the result can be interpreted by the naked eye, gel electrophoresis analysis is not essential. This method could allow the national malaria control programmes in less developed countries to monitor ace-1 R mutation incidence on a local level and to facilitate insecticide selection for bed net treatment or indoor use. In this study, AS-LAMP operated with a water bath actually obtained the same result as with a turbidimeter, although the number of samples tested was limited. A turbidimeter is extremely useful when establishing novel LAMP methods because it provides real-time information of amplification, although some set-up cost is required (approximately two times or less that of a standard thermal cycler). However, this machine is not essential in routine examinations using LAMP.

Another advantage of LAMP is its high reaction speed: it is actually similarly fast to RT-PCR and faster than PCR-RFLP. The times required of AS-LAMP and PCR prior to RFLP analysis are similar as well. However, RFLP analysis requires another few hours for restriction digestion and gel electrophoresis analysis. Furthermore, the restriction digestion time used in this study was chosen to follow the MR4 protocol [25], but on the longer side of the manufacturer’s suggestion (1 h) in order to prevent incomplete digestion.

A problem with the PCR-RFLP-based method, and presumably the AS-LAMP method also, is its inability to even tentatively detect duplication of the ace-1 gene, which is increasingly common and linked to resistance to insecticide [1113]. The RT-PCR method does not do this perfectly, but can nonetheless provide quantitatively useful information [26]. In this study, RT-PCR could not distinguish clearly the resistant homozygous versus the heterozygous genotypes. This might have been caused by gene duplication, although this is only speculation and was not confirmed here.

Resistance to insecticides requires regular monitoring. The tested method can readily be used for detecting the ace-1 R mutation with minimum equipment, and may serve as an alternative to PCR-RFLP for resistance monitoring in less equipped laboratories and for quick decision-making. Further development of LAMP-based detection kits or chips could be revolutionary tools for malaria vector control in developing countries by detecting epidemiologically important resistance to insecticide level at the site of transmission.

Conclusion

The AS-LAMP method with both FIP and BIP specific primers to detect the ace-1 R mutation in An. gambiae is similar to the PCR method in terms of specificity and sensitivity, with the added advantage of less required facilities.

References

  1. WHO. World malaria report 2013. Geneva: World Health Organization, 2013. http://www.who.int/malaria/media/world_malaria_report_2013/en/.

  2. Thera MA, Plowe CV. Vaccines for malaria: how close are we? Annu Rev Med. 2012;63:345–57.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  3. WHO. Resolution WHA58. 2. Malaria control. Geneva: World Health Organization, 2005 58th World Health Assembly, 23 May 2005.

  4. Badolo A, Traore A, Jones C, Sanou A, Flood L, Guelbeogo WM, et al. Three years of insecticide resistance monitoring in Anopheles gambiae in Burkina Faso: resistance on the rise? Malar J. 2012;11:232.

    Article  PubMed Central  PubMed  Google Scholar 

  5. Ranson H, Abdallah H, Badolo A, Guelbeogo WM, Kerah-Hinzoumbé C, Yangalbé-Kalnoné E, et al. Insecticide resistance in Anopheles gambiae: data from the first year of a multi-country study highlight the extent of the problem. Malar J. 2009;8:299.

    Article  PubMed Central  PubMed  Google Scholar 

  6. Namountougou M, Simard F, Baldet T, Diabate A, Ouedraogo JB, Martin T, et al. Multiple insecticide resistance in Anopheles gambiae s.l. populations from Burkina Faso, West Africa. PLoS One. 2012;7:e48412.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  7. Namountougou M, Diabate A, Etang J, Bass C, Sawadogo SP, Gnankinie O, et al. First report of the L1014S kdr mutation in wild populations of Anopheles gambiae M and S molecular forms in Burkina Faso (West Africa). Acta Trop. 2013;125:123–7.

    Article  CAS  PubMed  Google Scholar 

  8. Toe KH, Jones CM, N’Fale S, Ismail HM, Dabire RK, Ranson H. Increased pyrethroid resistance in malaria vectors and decreased bed net effectiveness, Burkina Faso. Emerg Infect Dis. 2014;20:1691–6.

    Article  PubMed Central  PubMed  Google Scholar 

  9. Toe KH, N’Fale S, Dabire RK, Ranson H, Jones CM. The recent escalation in strength of pyrethroid resistance in Anopheles coluzzi in West Africa is linked to increased expression of multiple gene families. BMC Genom. 2015;16:146.

    Article  Google Scholar 

  10. Weill M, Malcolm C, Chandre F, Mogensen K, Berthomieu A, Marquine M, et al. The unique mutation in ace-1 giving high insecticide resistance is easily detectable in mosquito vectors. Insect Mol Biol. 2004;13:1–7.

    Article  CAS  PubMed  Google Scholar 

  11. Djogbenou L, Chandre F, Berthomieu A, Dabire R, Koffi A, Alout H, et al. Evidence of introgression of the ace-1 R mutation and of the ace-1 duplication in West African Anopheles gambiae s. s. PLoS One. 2008;3:e2172.

    Article  PubMed Central  PubMed  Google Scholar 

  12. Weetman D, Mitchell SN, Wilding CS, Birks DP, Yawson AE, Essandoh J, et al. Contemporary evolution of resistance at the major insecticide target site gene Ace-1 by mutation and copy number variation in the malaria mosquito Anopheles gambiae. Mol Ecol. 2015;24:2656–72.

    Article  CAS  PubMed  Google Scholar 

  13. Edi CV, Djogbenou L, Jenkins AM, Regna K, Muskavitch MA, Poupardin R, et al. CYP6 P450 enzymes and ACE-1 duplication produce extreme and multiple insecticide resistance in the malaria mosquito Anopheles gambiae. PLoS Genet. 2014;10:e1004236.

    Article  PubMed Central  PubMed  Google Scholar 

  14. Djogbenou L, Dabire R, Diabate A, Kengne P, Akogbeto M, Hougard JM, et al. Identification and geographic distribution of the ACE-1 R mutation in the malaria vector Anopheles gambiae in south-western Burkina Faso, West Africa. Am J Trop Med Hyg. 2008;78:298–302.

    CAS  PubMed  Google Scholar 

  15. Alonso PL, Besansky NJ, Burkot TR, Collins FH, Hemingway J, James AA, et al. A research agenda for malaria eradication: vector control. PLoS Med. 2011;8:e1000401.

    Article  Google Scholar 

  16. TmCGoV Control. A research agenda for malaria eradication: vector control. PLoS Med. 2011;8:e1000401.

    Article  Google Scholar 

  17. Aonuma H, Suzuki M, Iseki H, Perera N, Nelson B, Igarashi I, et al. Rapid identification of Plasmodium-carrying mosquitoes using loop-mediated isothermal amplification. Biochem Biophys Res Commun. 2008;376:671–6.

    Article  CAS  PubMed  Google Scholar 

  18. Aonuma H, Yoshimura A, Kobayashi T, Okado K, Badolo A, Nelson B, et al. A single fluorescence-based LAMP reaction for identifying multiple parasites in mosquitoes. Exp Parasitol. 2010;125:179–83.

    Article  CAS  PubMed  Google Scholar 

  19. Aonuma H, Yoshimura A, Perera N, Shinzawa N, Bando H, Oshiro S, et al. Loop-mediated isothermal amplification applied to filarial parasites detection in the mosquito vectors: Dirofilaria immitis as a study model. Parasit Vectors. 2009;2:15.

    Article  PubMed Central  PubMed  Google Scholar 

  20. Notomi T, Okayama H, Masubuchi H, Yonekawa T, Watanabe K, Amino N, et al. Loop-mediated isothermal amplification of DNA. Nucleic Acids Res. 2000;28:E63.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  21. Mori Y, Nagamine K, Tomita N, Notomi T. Detection of loop-mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation. Biochem Biophys Res Commun. 2001;289:150–4.

    Article  CAS  PubMed  Google Scholar 

  22. Perera N, Aonuma H, Yoshimura A, Teramoto T, Iseki H, Nelson B, et al. Rapid identification of virus-carrying mosquitoes using reverse transcription-loop-mediated isothermal amplification. J Virol Methods. 2009;156:32–6.

    Article  CAS  PubMed  Google Scholar 

  23. Bonizzoni M, Afrane Y, Yan G. Loop-mediated isothermal amplification (LAMP) for rapid identification of Anopheles gambiae and Anopheles arabiensis mosquitoes. Am J Trop Med Hyg. 2009;81:1030–4.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  24. Badolo A, Okado K, Guelbeogo WM, Aonuma H, Bando H, Fukumoto S, et al. Development of an allele-specific, loop-mediated, isothermal amplification method (AS-LAMP) to detect the L1014F kdr-w mutation in Anopheles gambiae s. l. Malar J. 2012;11:227.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  25. MR4. Methods in Anopheles research. 4th edition; 2014.

  26. Bass C, Nikou D, Vontas J, Williamson MS, Field LM. Development of high-throughput real-time PCR assays for the identification of insensitive acetylcholinesterase (ace-1(R)) in Anopheles gambiae. Pestic Biochem Physiol. 2010;96:80–5.

    Article  CAS  Google Scholar 

  27. Newcombe RG. Two-sided confidence intervals for the single proportion: comparison of seven methods. Stat Med. 1998;17:857–72.

    Article  CAS  PubMed  Google Scholar 

  28. Corbel V, N’Guessan R, Brengues C, Chandre F, Djogbenou L, Martin T, et al. Multiple insecticide resistance mechanisms in Anopheles gambiae and Culex quinquefasciatus from Benin, West Africa. Acta Trop. 2007;101:207–16.

    Article  CAS  PubMed  Google Scholar 

  29. Dabire KR, Diabate A, Djogbenou L, Ouari A, N’Guessan R, Ouedraogo JB, et al. Dynamics of multiple insecticide resistance in the malaria vector Anopheles gambiae in a rice growing area in South-Western Burkina Faso. Malar J. 2008;7:188.

    Article  PubMed Central  PubMed  Google Scholar 

  30. Ranson H, N’Guessan R, Lines J, Moiroux N, Nkuni Z, Corbel V. Pyrethroid resistance in African anopheline mosquitoes: what are the implications for malaria control? Trends Parasitol. 2011;27:91–8.

    Article  CAS  PubMed  Google Scholar 

  31. Brooke BD, Kloke G, Hunt RH, Koekemoer LL, Temu EA, Taylor ME, et al. Bioassay and biochemical analyses of insecticide resistance in southern African Anopheles funestus (Diptera: Culicidae). Bull Entomol Res. 2001;91:265–72.

    Article  CAS  PubMed  Google Scholar 

Download references

Authors’ contributions

AB and SF conceived the study and wrote the paper. AB designed the primers and carried out the molecular study. MK, HB and HK performed experiments in the laboratory. AB, AT, WMG, NS and HR contributed to the fieldwork related to collecting the Anopheles mosquitoes. All authors read and approved the final manuscript.

Acknowledgements

This study was supported in part by a grant from the Japan International Cooperation Agency (JICA) to AB and SF, and Grants-in-Aid for Scientific Research from the Japanese Ministry of Education, Science, Sports, Culture and Technology to SF and HK. This investigation received financial support from the UNICEF/UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases (WHO/TDR) through the grant A70588 to HR.

Competing interests

The authors declare that they have no competing interests.

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Athanase Badolo or Shinya Fukumoto.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Badolo, A., Bando, H., Traoré, A. et al. Detection of G119S ace-1 R mutation in field-collected Anopheles gambiae mosquitoes using allele-specific loop-mediated isothermal amplification (AS-LAMP) method. Malar J 14, 477 (2015). https://doi.org/10.1186/s12936-015-0968-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12936-015-0968-9

Keywords