• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of an Automated Dual Type of Micro Stopped-Flow/Flow-Injection Apparatus Applicable for Detection of Minute Alteration of Inorganic Phosphate or Phosphoric Group in Protein Level

Research Project

Project/Area Number 01870077
Research Category

Grant-in-Aid for Developmental Scientific Research (B).

Allocation TypeSingle-year Grants
Research Field Functional basic dentistry
Research InstitutionOkayama University

Principal Investigator

TANIGUCHI Shigehiko  Okayama University Dental School, Professor, 歯学部, 教授 (50034161)

Co-Investigator(Kenkyū-buntansha) YASUDA Kazuo  Naka Works, Hitachi, Ltd., Superintendent Engineer, 計測事業部, 主管技師長
TAKAHASHI Kojiro  Okayama University Dental School, Assistant Professor, 歯学部, 助手 (00144775)
Project Period (FY) 1989 – 1990
Project Status Completed (Fiscal Year 1990)
Budget Amount *help
¥3,400,000 (Direct Cost: ¥3,400,000)
Fiscal Year 1990: ¥800,000 (Direct Cost: ¥800,000)
Fiscal Year 1989: ¥2,600,000 (Direct Cost: ¥2,600,000)
KeywordsHard tissues / Phosphorylation / Dephosphorylation / Micro-autoanalyzer / Stopped-flow method / Flow-injection analysis / 骨・硬組織
Research Abstract

By combination of two sets of stopped-flow/flow-injection apparatus (single SF-FIA apparatus), an automated dual SF-FIA apparatus was constructed for serial measurements of minute alteration of inorganic phosphate (Pi) or phosphoric groups in protein level related to calcification of hard tissues or phosphorylation/dephosphorylation cycle of growth control system in normal/cancer cells. The dual SF-FIA apparatus was further installed by an intelligent auto sampler in order to carry out some complex pre-treatments of sample. Normally, the quatitative change of phosphorylation/dephosphorylation in protein level by phosphatase or kinase, respectively, can be detected spectrophotometrically through a direct method to free Pi using Malachite Green/molybdate reagent or an indirect method measuring NADH stoichiometrically reflecting ATP/ADP change in consecutive enzyme assay system. Furthermore, the dual SF-FIA apparatus could be applied as a rapid (msec order) stopping tool required for ^<32>P-labeling method by using filtration with milipore membrane. With 29.4 ul for each of sample and assay solution per one cycle measuring, half-hundred of serial measurements by using the dual SF-FIA apparatus are possible for the total volume of 3.0 ml for each of sample and assay solution. The time interval among the serial measurements with the dual SF-FIA apparatus can be set up within an arbitrary range longer than 4 sec.

Report

(3 results)
  • 1990 Annual Research Report   Final Research Report Summary
  • 1989 Annual Research Report
  • Research Products

    (3 results)

All Other

All Publications (3 results)

  • [Publications] Kojiro Takahashi: "A kinetic study of phosphorylation/dephosphorylation in protein level by an dual type of micro stoppedーflowーinjecition apparatus." Anal.Biochem.

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] K. Takahashi, K. Yasuda, T. Kuroishi and S. Taniguchi: "A kinetic study of phosphorylation/dephosphorylation in protein level by a dual type of micro stopped-flow/flow-injection apparatus." Anal. Biochem.

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] Kojiro Takahashi: "A Kinetic study of phosphorylation/dephosphorylation in protein level by an dual type of micro stoppedーflow/flowーinjecition apparatus." Anal.Biochem.

    • Related Report
      1990 Annual Research Report

URL: 

Published: 1989-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi