• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Bone mineral densitometry using a cooled CCD camera

Research Project

Project/Area Number 04454292
Research Category

Grant-in-Aid for General Scientific Research (B)

Allocation TypeSingle-year Grants
Research Field Radiation science
Research InstitutionTOHOKU UNIVERSITY

Principal Investigator

KATAKURA Tsuyosi  TOHOKU UNIVERSITY,MEDICAL SCIENCES,PROFESSOR., 医療技術短期大学部, 教授 (10004920)

Co-Investigator(Kenkyū-buntansha) OHISHI Mikio  TOHOKU UNIVERSITY,MEDICAL SCIENCES,RESARCH ASSOCIATE, 医療技術短期大学部, 助手 (20004921)
SUZUKI Shogo  TOHOKU UNIVERSITY,MEDICAL SCIENCES,ASSOCIATE PROFESSOR., 医療技術短期大学部, 助教授 (00004870)
Project Period (FY) 1992 – 1993
Project Status Completed (Fiscal Year 1993)
Budget Amount *help
¥3,900,000 (Direct Cost: ¥3,900,000)
Fiscal Year 1993: ¥600,000 (Direct Cost: ¥600,000)
Fiscal Year 1992: ¥3,300,000 (Direct Cost: ¥3,300,000)
KeywordsDigital radiography / Bone mineral densitometry / Energy subtraction / CCD camera / 医用画像処理 / 骨粗鬆症
Research Abstract

The mass examination of bone mineral density is very important for preventing fracture at older ages, especially over 60 years old. We have developed X-ray bone mineral densitometry system using a cooled CCD camera which is very simple and has high stability and noiseless imaging. Furthermore, this CCD camera has linear proportionality, so that we have designed a equipment using the dual energy subtraction method.
Our system consist of, mainly, an X-ray generator, attenuation filters, a screen, and a cooled CCD camera. This camera, which is developed by HAMAMATSU,is cooled at -30゚C by an electric cooler, so that CCD noise and dark currents decrease to very low level. The subject of metacarpal or radius is set on the fluorescent screen and exposed by two shots of X-ray at 55kV and 80kV through each attenuation filter and these images are showed on the monitor
In this method, we obtained the results of good separation between the soft tissue and bone components. Our equipment has high-sensitivity, high-stability, and short examination time, therefore, this is quite useful to mass examination of the bone mineral density

Report

(3 results)
  • 1993 Annual Research Report   Final Research Report Summary
  • 1992 Annual Research Report
  • Research Products

    (6 results)

All Other

All Publications (6 results)

  • [Publications] 大石 幹男: "冷却CCDカメラを用いたX線テレビジョンの開発" 東北大医短部紀要. 1. 27-35 (1991)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] 片倉 剛: "Method of X-Ray Bone mineral Deneitometry Vsing a Cooled CCD Camera" Medical & Biological Engineering & Computing. 29. 864-865 (1991)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] 片倉 剛: "冷却CCDカメラによる骨塩測定システムの開発" 日本放射線技術学会雑誌. 48. 1267 (1992)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] 大石 幹雄: "C-CCDカメラ型ディジタルラジオグラフィーシステムの開発" 日本放射線技術学会雑誌. 50. 614-621 (1994)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] KATAKURA Tsuyosi: "Method of X-Ray Bone mineral Densitometry Using a Cooled CCD Camera" Medical & Biological Engineering & computing. Vol 29. 865 (1991)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] OHISHI Mikio: "Development of Digital Radiorphy System Using a Cooled CCD Camera" Japanese Journal of Radiological Technology. Vol.50, No.5. 614-621 (1994)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary

URL: 

Published: 1992-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi