• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Quantitative Study in Absorption of Mandible Caused by Aging and Disease

Research Project

Project/Area Number 04454481
Research Category

Grant-in-Aid for General Scientific Research (B)

Allocation TypeSingle-year Grants
Research Field 補綴理工系歯学
Research InstitutionTokyo Medica and Dental University

Principal Investigator

NAGAO Masanori  Tokyo Medical & Dental Univ., Dept.of Geriatric Dentistry, Professor, 歯学部, 教授 (60014213)

Co-Investigator(Kenkyū-buntansha) KATOH Tsuguhisa  Tokyo Medical & Dental Univ., Dept.of Radology and Radiation Research, Research, 歯学部, 助手 (70095107)
SEKITA Toshiaki  Tokyo Medical & Dental Univ., Dept.of Geriatric Dentistry, Research Associate, 歯学部, 助手 (90236092)
MINAKUCHI Shunsuke  Tokyo Medical & Dental Univ., Dept.of Geriatric Dentistry, Research Associate, 歯学部, 助手 (30219688)
KOBAYASHI Kenichi  Tokyo Medical & Dental Univ., Dept.of Geriatric Dentistry, Lecturer, 歯学部, 講師 (00170316)
Project Period (FY) 1992 – 1994
Project Status Completed (Fiscal Year 1994)
Budget Amount *help
¥6,900,000 (Direct Cost: ¥6,900,000)
Fiscal Year 1994: ¥800,000 (Direct Cost: ¥800,000)
Fiscal Year 1993: ¥900,000 (Direct Cost: ¥900,000)
Fiscal Year 1992: ¥5,200,000 (Direct Cost: ¥5,200,000)
KeywordsAbsorption of mandible / dual energy subtraction / quantitative image / bone mineral content
Research Abstract

Absorption of mandible is caused by aging, desease, and prosthetic Factors. It is difficult to estimate these absorption, and if possible, that is useful information for the prosthetic treatment, design and prognosis of prosthetics. Therefore, there were many studies in absorption of mandible with the tool of radiology, histology and biochemistry. But, there was no quantitative study in absorption of mandible and no method which can make quantitative measurements of bone mineral content. In this respect, we developed a sistem which can produce a quantitative image of bone mineral content. The system consists of a radiographing system and an image processor. Two radiograms were taken with dual X-ray energy in a single exposure using an X-ray beam dichromized by a tin filter. The image processing included the corrections of the film characteristics and heterogeneity in the X-ray field, and the dual energy subtraction in which the effect of the high energy component of the dichromized beam on the tube side image as corrected. In order to determine conditions of exposure of X-ray and some parameters of image analysis, experiments using wedge phantoms made of mixtures of epoxy resin and bone mineral-equvalent materials in various fractions were performed. The results as follows : the best tube potetials were from 60kV to 70kV.10x10 pixels image sample was suitable for image processing and it could make the best accuracy for the measurement of bone mineral content.

Report

(4 results)
  • 1994 Annual Research Report   Final Research Report Summary
  • 1993 Annual Research Report
  • 1992 Annual Research Report

URL: 

Published: 1992-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi