• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Toward an implantable Axial intra-Cardiac Blood Pump : The Valvo-pump

Research Project

Project/Area Number 04557061
Research Category

Grant-in-Aid for Developmental Scientific Research (B)

Allocation TypeSingle-year Grants
Research Field Thoracic surgery
Research InstitutionKeio University

Principal Investigator

YOZU Ryohei  Keio Univ.Sch.of Med.Assistant Prof., 医学部, 講師 (30129738)

Co-Investigator(Kenkyū-buntansha) ONOKUCHI Katsuhisa  Keio Univ.Sch.of Med.Resident., 医学部, 助手 (00214198)
ITO Tsutomu  Keio Univ.Sch.of Med.Resident., 医学部, 助手 (00232455)
MITAMURA Yoshinori  Hokkaido Tokai Univ, Sch.of Eng, Prof., 工学部, 教授 (70002110)
Project Period (FY) 1992 – 1993
Project Status Completed (Fiscal Year 1993)
Budget Amount *help
¥5,000,000 (Direct Cost: ¥5,000,000)
Fiscal Year 1993: ¥1,300,000 (Direct Cost: ¥1,300,000)
Fiscal Year 1992: ¥3,700,000 (Direct Cost: ¥3,700,000)
KeywordsValvo-pump / Circulatory support / Axial flow pump / Artificial heart / Nonpulsatile flow / Blood pump / Assisted Circulation / Ferrofluidic seal / Valvo‐Pump
Research Abstract

We have developed the Valvo-Pump, an axial flow blood pump, which is implanted at the natural heart valve position. This device has several advantages ; it fits well anatomically, its blood-contacting surface is small because the left or right ventricular cavity is used as the blood storage reservoir, and it is implanted as easily as an artificial heart valve replacement. The Valvo-Pump consists of an impeller and a motor, both of which are encased in a housing. An impeller with 5 vanes (22.0mm in diameter) is connected to a samariumm-cobalt-rare earth magnet direct current (DC) brushless motor (21.3mm in diameter and 24.9-mm-long). Sealing is achieaved by means of aferrofruidic seal. A pump flow of 16.11/min was obtained at a pump differential pressure of 7.7 kPa (58mmHg), and a flow of 5.01/min at 18.4 kPa (318mmHg) with a motor speed of 8500 revolutions per min (rpm). Sealing was kept perfect against a pressure of 29.3 kPa (220mmHg) at 9000 rpm. The Valvo-Pump is a very promising and simple method of circulatory support.

Report

(3 results)
  • 1993 Annual Research Report   Final Research Report Summary
  • 1992 Annual Research Report
  • Research Products

    (23 results)

All Other

All Publications (23 results)

  • [Publications] 四津良平,三田村好矩 他: "新方式、人工心臓の開発 超小型血液ポンプ(Valvo-Pump)の心内埋め込み" 日本臨床. 49. 230-236 (1991)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] 古梶清和,四津良平 他: "補助循環から置換外科へ 心臓移植、Valvo-Pumpへの補助人工心臓(VAS)" 人工臓器. 21. 52-58 (1992)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] 四津良平 他: "遠心ポンプの臨床 補助循環に対する応用" 人工臓器. 21. 123-129 (1992)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] 山崎健一,四津良平 他: "心臓弁位置埋込型人工血液ポンプ(Valvo-Pump)の開発" 人工臓器. 21. 567-571 (1992)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Kenichi Yamazaki,Ryohei Yozu,et al: "THOUGHTS AND PROGRESS:The Valvo-Pump,An Axial Blood Pump Implanted at the Heart Valve Position:Concept and Initial Results" Artificial Oragans. 16. 297-299 (1992)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Y.Mitamura R.Yozu,et al: "TOWARD ANINTRA-CARDIAC AXIAL FLOW PUMP 開催地 三重" The First congress of the international society for Rotary Blood Pump. (1993)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] R.Yozu,Y.Mitamura,et al: "Artificial Heart 4 Toward an Implantable Axial Intra-Cardiac Blood Pump:The Valvo-Pump p.267-272" Springer-Verlag,Tokyo T.Akutsu,H.Hoyanagi(Eds.), 424 (1993)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Y.Mitamura, R.Yozu, et al: "Valvo-Pump" INFA INTERNATIONAL SCHOOL 1992 INTERNATIONAL SYNPOSIUM ON ROTARY BLOOD PUMP - THE 2ND GENERATION CARDIOPULMONARY BYPASS PUMP AND BEYOND (Houston TX). (1992)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Y.Mitamura, R.Yozu, et al: "Toward An Intra-Cardiac Axial Flow Pump." THE FIRST CONGRESS OF THE INTERNATIONAL SOCIETY FOR ROTABY BLOOD PUMPS. (1993)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] R.Yozu, Y.Mitamura, et al: "Artificial Heart 4 Toward an implantable axial intra-cardiac blood pump : The Valvo-Pump" Springer - Verlag, Tokyo T.Akutsu, H.Koyanagi (eds). 267-272 (1993)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Kenichi Yamzaki, Ryohei Yozu, et al: "THOUGHTS AND PROGRESS The Valvo-Pump, An Axial Blood Pump Implanted at the Heart Valve Position : Concept and Initial Results" Artificial Organs. 16. 297-299 (1992)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] 古梶清和 四津良平他: "補助循環から置換外科へ 心臓移植,Valvo‐Pumpへの補助人工心臓(VAS)" 人工臓器. 21. 52-58 (1992)

    • Related Report
      1993 Annual Research Report
  • [Publications] 四津良平他: "遠心ポンプの臨床 補助循環に対する応用" 人工臓器. 21. 123-129 (1992)

    • Related Report
      1993 Annual Research Report
  • [Publications] 山崎健一 四津良平他: "心臓弁位置埋込型人工血液ポンプ(Valvo‐Pump)の開発" 人工臓器. 21. 567-571 (1992)

    • Related Report
      1993 Annual Research Report
  • [Publications] Kenichi Yamazaki,Ryohei Yozu,et al: "THOUGHTS AND PROGRESS:The Valvo‐Pump,An Axial Blood Pump Implanted at the Heart Valve Position:Concept and Initial Results" Artificial Organs. 16. 297-299 (1992)

    • Related Report
      1993 Annual Research Report
  • [Publications] Y.Mitamura,R.Yozu,et al: "Valo Pump" INFA INTERATIONAL SCHOOL 1992 INTERNATIONAL SYMPOSIUM ON ROTARY BLOOD PUMP-THE 2ND GENERATION CARDIOPULMONARY BYPASS PUMP AND BEYOND-(Houston Tx.). (1992)

    • Related Report
      1993 Annual Research Report
  • [Publications] Y.Mitamura,R.Yozu,et al: "TOWARD AN INTRA‐CARDIAC AXIAL FLOW PUMP." THE FIRST CONGRESS OF THE INTERNATIONAL SOCIETY FOR ROTARY BLOOD PUMPS(三重). (1993)

    • Related Report
      1993 Annual Research Report
  • [Publications] R.Yozu,Y.Mitamura,et al: "Artificial Heart 4 Toward an Implantable Axial Intra‐Cardiac Blood Pump:The Valvo‐Pump" Springer‐Verlag,Tokyo T.Akutsu,H.Hoyanagi(Eds.), 424(267-272) (1993)

    • Related Report
      1993 Annual Research Report
  • [Publications] 古梶 清和 四津 良平他: "補助循環から置換外科へ 心臓移植,Valvo-Pumpへの補助人工心臓(VAS)" 人工臓器. 21. 52-58 (1992)

    • Related Report
      1992 Annual Research Report
  • [Publications] 四津 良平他: "遠心ポンプの臨床 補助循環に対する応用" 人工臓器. 21. 123-129 (1992)

    • Related Report
      1992 Annual Research Report
  • [Publications] 山崎 健一 四津 良平他: "心臓弁位置埋込型人工血液ポンプ (Valvo-Pump)の開発" 人工臓器. 21. 567-571 (1992)

    • Related Report
      1992 Annual Research Report
  • [Publications] Kenichi Yamazaki,Ryohei Yozu,et al: "THOUGHTS AND PROGRESS:The Valvo-Pump,An Axial Blood Pump Implanted at the Heart Valve Position:Concept and Initial Results" Artificial Organs. 16. 297-299 (1992)

    • Related Report
      1992 Annual Research Report
  • [Publications] R.Yozu,Y.Mitamura,et al: "Artificial Heart 4" Springer-Verlag,Tokyo T.Akutsu,H.Koyanagi(Eds.), (1993)

    • Related Report
      1992 Annual Research Report

URL: 

Published: 1992-04-01   Modified: 2016-04-21  