Development of an Image Analyzing System for Cardiovascular Morphorogy and Dynamics using Synchrotron Radiation Imaging

Research Project

Project/Area Number 04557113
Research Category

Grant-in-Aid for Developmental Scientific Research (B)

Allocation TypeSingle-year Grants
Research Field 医学一般
Research InstitutionYamagata University

Principal Investigator

AKATSUKA Takao  Yamagata Univ., Faculty of Engineering Professor, 工学部, 教授 (80091875)

Co-Investigator(Kenkyū-buntansha) HIRANAKA Yukio  Yamagata Univ., Fac.of Engineering Assoc.Prof., 工学部, 助教授 (40134465)
TAKEDA Tohoru  Univ.of Tsukuba, Inst.of Clinical Med., Assistant Prof., 臨床医学系, 講師 (10197311)
HYODO Kazuyuki  KEK, Photon Factory, Research Associate, 放射光実験施設, 助手 (60201729)
HASEGAWA Shin  Univ.of Electro-Communications, Dep.of E.E.Professor, 電気通信学部, 教授 (60017308)
ANDO Masaomi  KEK, Photon Factory Professor, 放射光実験施設, 教授 (30013501)
Project Period (FY) 1992 – 1993
Project Status Completed (Fiscal Year 1993)
Budget Amount *help
¥9,300,000 (Direct Cost: ¥9,300,000)
Fiscal Year 1993: ¥2,200,000 (Direct Cost: ¥2,200,000)
Fiscal Year 1992: ¥7,100,000 (Direct Cost: ¥7,100,000)
KeywordsSynchrotron Radiation / Digital Subtraction Angiography / Cardiac Function / Time Varying Image Processing / Energy Subtraction Image / Image Recording / Monochromatic X-ray / Measurement on Image
Research Abstract

The final goal of this project is to detect cardiovascular abnormality in its early stage. For this purpose synchrotron radiation (SR) imaging is quite useful to find precise structure on moving organs, and it gives us spectral information of objects. On the other hand, we can get more exact structures and functions of living organs from time sequence images. Here we developed a system and several algorithms to realize such analysis.
Two spectrum images obtained in 2ms, i.e. ignorable time interval for cardiac motion, image data sequences are recorded in IC memory bank with required reference time series signal. Each image data is 512x512 size with 12bit depth, and the usual time difference between two spectrum image sequences is 2ms. For fast correction of image distortion and real time DSA, a fast data processing board is prepared and more sophisticated processing are executed on a work station connected to this recording system.
Several basic algorithms for the analysis of image sequence and information extraction for evaluation of organs are developed on related practical problems, e.g. 3D coronary structure identification from biplane image time sequences, detection and tracking moving targets and imaging of specific materials in organs from spectrum images.
A few problems on the optical system for SR imaging is also studied. For the suppression of scattering X-ray flux and the fast switching of X-ray spectrum for energy subtraction imaging, we found solutions, and their implementation are continuing. Improvement of diagnosing algorithm and clinical evaluation of this system is the next problem.

Report

(3 results)
  • 1993 Annual Research Report   Final Research Report Summary
  • 1992 Annual Research Report
  • Research Products

    (52 results)

All Other

All Publications (52 results)

  • [Publications] K.Hyodo: "A new proposal on use of the dual beam produced by an elliptic-MPW for angiography" Rev.Sci.Instrum.63. 601-603 (1992)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] H.Shiwaku: "X-ray characterization of lapped Si surfaces for coronary angiogrphy with 311 reflection at 33.17Kev" Rev.Sci.Instrum.63. 1201-1203 (1992)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] 深川浩志: "KエッジサブトラクションX線テレビシステム" 医用画像情報学会誌. 9. 83-90 (1992)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] T.Takeda: "Synchrotron radiation X-ray computed tomography to detect tracer material" Med.Imag.Tech.10. 299-299 (1992)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] 兵籐一行: "K吸収端差分用画像処理システムの開発とディジタルフィルターを用いた画質改善の試み" PFシンポジウム講演予稿集. 10. 39-39 (1992)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] 武田徹: "放射光を用いた微量元素検出型単色X線CT" INNERVISION. 8. 120-124 (1993)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] K.Umetani: "Two-dimensional real time imaging system for subtraction angiography using an iodine filter" Rev.Sci.Instruments. 63. 29-31 (1992)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] K.Umetani: "Iodine filter imaging system for subtraction angiography using synchrotron radiation" Nuclear Instruments and Methods in Physics Res.335. 569-579 (1993)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] 武田 徹: "放射光CTの開発動向" Med.Imaging Technology. 11. 621-627 (1993)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] T.Takeda: "High special resolution CT with a synchrotron radiation system" J.of Computer Assisted Tomography. 18. 98-101 (1994)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] 武田 徹: "シンクロトロン放射光の医学利用" Isotope News. 1-9 (1993)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Y.Nagata: "High energy high resolution monochromatic X-ray computed tomography using synchrotron radiation" Nondestr.Test Evaluation. 7. 55-78 (1992)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Y.Nagata: "High energy high resolution monochromatic X-ray computed tomography system" Res.Nondestr.Evaluation. 4. 5-78 (1992)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] M.Ando: "10 years of medicine and biology at the Photon Factory" Synchrotron Radiation News. 6. 19-31 (1993)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] 陳黎 明: "行列型画像表示デバイスの2次元視認解像度限界" テレビジョン学会誌. 9. 83-90 (1992)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Li-M.Chen: "Visual resolution limits for color matrix displays" Displays. 13. 179-186 (1992)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Li-M.Chen: "Influence of pixel-structure noise on image resolution and color for matrix display devices" J.of the SID. 1. 103-110 (1993)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Y.Oku: "Conceptual design of a compact electron storage ring system dedicated coronary angiography" Proc.of Partial Accelerator Conference. 1468-1470 (1993)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] K.Hyodo, et al: "A new proposal on use of the dual beam produced by an elliptic-MPW(EMPW) for angiography" Rev.Sci.Instrm.Vol.63(1). 601-603 (1992)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] H.Shiwaku, et al: "X-ray characterization of lapped Si surfaces for coronary angiography with 311 reflection at 33.17KeV" Rev.Sci.Instrm.Vol.63(1). 1201-1203 (1992)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] K.Umetani, et al: "Two-dimensional real time imaging system for subtraction angiography using an iodine filter" Rev.Sci.Instrm.Vol.63(1). 629-631 (1992)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Y.Nagata, et al: "High energy high resolution monochromatic X-ray computed tomography using synchrotron radiation" Nondestr.Test Evaluation. Vol.7. 299-307 (1992)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Y.Nagata, et al: "High energy high resolution monochromatic X-ray computed tomography system" Res.Nondestr.Test Evaluation. Vol.4. 55-78 (1992)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] H.Fukagawa, et al: "K-edge subtraction X-ray television system-Animal experiment-" Japanese J.of Med.Imaging and Information Sciences. Vol.9(2). 83-90 (1992)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Li-M.Chen, et al: "Two-dimensional visual resolution limits for matrix display devices" ITEJ. Vol.46(5). 615-623 (1992)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Li-M.Chen, et al: "Visual resolution limits for color matrix displays" Displays. Vol.13(4). 179-186 (1992)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Li-M.Chen, et al: "Influence of pixel-structure noise on image resolution and color for matrix display devices" J.of the SID. Vol.1(1). 103-110 (1993)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] K.Umetani, et al: "Iodine filter imaging system for subtraction angiography using synchrotron radiation" Nuclear Instrm.and Methods in Physics Research. A 335. 569-579 (1993)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] T.Takeda, et al: "The development of computed tomography with synchrotron radiation" Med.Imaging Tech.Vol.11(5). 621-627 (1993)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] T.Takeda, et al: "High spatial resolution CT with a synchrotron radiation system" J.of Computer Assisted Tomography. Vol.18(1). 98-101 (1994)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] M.Ando, et al: "Ten years of medicine and biology at the photon factory" Synchrotron Radiation News. Vol.6. 19-31 (1993)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Y.Oku, et al: "Conceptual design of a compact electron storage ring system dedicated coronary angiography" Proc.of Particle Accelerator Conference. 1468-1470 (1993)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] K.Hyodo: "Development of X-ray monochrometor for medical diagnosing system" Japn.J.Med.Phys.Vol.13(3). 265-272 (1993)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] T.Takeda, et al: "Review of coronary angiography using synchrotron dadiation" Japn.J.Med.Phys.Vol.13(2). 155-161 (1993)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] K.Umetani: "Two-dimensional real time imaging system for subtraction angiography using an iodine filter" Rev.Sci.Instruments. 63. 29-31 (1992)

    • Related Report
      1993 Annual Research Report
  • [Publications] K.Umetani: "Iodine filter imaging system for subtraction angiography using synchrotron radiation" Nuclear Instruments and Methods in Physics Res.335. 569-579 (1993)

    • Related Report
      1993 Annual Research Report
  • [Publications] 武田 徹: "放射光CTの開発動向" Med.Imaging Technology. 11. 621-627 (1993)

    • Related Report
      1993 Annual Research Report
  • [Publications] T.Takeda: "High special resolution CT with a synchrotron radiation system" J.of Computer Assisted Tomography. 18. 98-101 (1994)

    • Related Report
      1993 Annual Research Report
  • [Publications] 武田 徹: "シンクロトロン放射光の医学利用" Isotope News. 1-9 (1993)

    • Related Report
      1993 Annual Research Report
  • [Publications] Y.Nagata: "High energy high resolution monochromatic X-ray computed tomography using synchrotron radiation" Nondestr.Test Evaluation. 7. 55-78 (1992)

    • Related Report
      1993 Annual Research Report
  • [Publications] Y.Nagata: "High energy high resolution monochromatic X-ray computed tomography system" Res.Nondestr.Evaluation. 4. 5-78 (1992)

    • Related Report
      1993 Annual Research Report
  • [Publications] M.Ando: "10 years of medicine and biology at the Photon Factory" Synchrotron Radiation News. 6. 19-31 (1993)

    • Related Report
      1993 Annual Research Report
  • [Publications] 陳黎明: "行列型画像表示デバイスの2次元視認解像度限界" テレビジョン学会誌. 9. 83-90 (1992)

    • Related Report
      1993 Annual Research Report
  • [Publications] Li-M.Chen: "Visual resolution limits for color matrix displays" Displays. 13. 179-186 (1992)

    • Related Report
      1993 Annual Research Report
  • [Publications] Li-M.Chen: "Influence of pixel-structure noise on image resolution and color for matrix display devices" J.of the SID. 1. 103-110 (1993)

    • Related Report
      1993 Annual Research Report
  • [Publications] Y.Oku: "Conceptual design of a compact electron storage ring system dedicated coronary angiography" Proc.of Partial Accelerator Conference. 1468-1470 (1993)

    • Related Report
      1993 Annual Research Report
  • [Publications] K.Hyodo: "A new proposal on use of the dual beam produced by an elliptic-MPW for angiography" Rev.Sci.Instrum.63. 601-603 (1992)

    • Related Report
      1992 Annual Research Report
  • [Publications] H.Shiwaku: "X-ray characterization of lapped Si surfaces for coronary angiography with 3ll reflection at 33.17Kev" Rev.Sci.Instrum.63. 1201-1203 (1992)

    • Related Report
      1992 Annual Research Report
  • [Publications] 深川 浩志: "KエッジサブトラクションX線テレビシステム" 医用画像情報学会誌. 9. 83-90 (1992)

    • Related Report
      1992 Annual Research Report
  • [Publications] T.Takeda: "Synchrotron radiation X-ray computed tomography to detect tracer material" Med.Imag.Tech.10. 299-299 (1992)

    • Related Report
      1992 Annual Research Report
  • [Publications] 兵藤 一行: "K吸収端差分用画像処理システムの開発とディジタルフィルターを用いた画質改善の試み" PEシンポジウム講演予稿集. 10. 39-39 (1992)

    • Related Report
      1992 Annual Research Report
  • [Publications] 武田 徹: "放射光を用いた微量元素検出型単色X線CT" INNERVISION. 8. 120-124 (1993)

    • Related Report
      1992 Annual Research Report

URL: 