• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of a monitor for tidal volume using ECG to eliminate

Research Project

Project/Area Number 04671389
Research Category

Grant-in-Aid for General Scientific Research (C)

Allocation TypeSingle-year Grants
Research Field 医学一般
Research InstitutionTokyo Medical and Dental University

Principal Investigator

NOSHIRO Makoto  Tokyo Med. & Dent.Univ., Assoc.Prof., 医用器材研究所, 助教授 (80014231)

Co-Investigator(Kenkyū-buntansha) MIYAZAKI Shinji  Tokyo Med. & Dent.Univ., Instructor, 医用器材研究所, 助手 (10014284)
TSUJI Takayuki  National Cardiovasc. Center, Head, 実験治療開発部, 部長 (00075764)
ISHIDA Akimasa  Tokyo Med. & Dent.Univ., Prof., 医用器材研究所, 教授 (60016540)
Project Period (FY) 1992 – 1993
Project Status Completed (Fiscal Year 1993)
Budget Amount *help
¥2,100,000 (Direct Cost: ¥2,100,000)
Fiscal Year 1993: ¥600,000 (Direct Cost: ¥600,000)
Fiscal Year 1992: ¥1,500,000 (Direct Cost: ¥1,500,000)
KeywordsElectrocardiogram / Vector loop / Tidal volume / Ambulatory monitoring
Research Abstract

Lead-I and -III electrocardiograms were measured, A/D converted, and then processed by a note-type personal computer. The maximum and minimum values in the QRS complex were detected, and using Einthoven's delta, they were converted into the values in an orthogonal lead system. Then the difference between the maximum and minimum values was calculated. Finally, the angle of a vector was obtained which consisted of the lead-I difference and the difference in the lead orthogonal to the lead-I.The angles obrained at the interval of heart beat were interpolated by a cubic spline function to yield a continuous curve. The difference between a local maxsimum and minimum in the curve gave the estimate for a relative value of tidal volume. These data processings were done on a real-time basis. Simultaneously with the electrocardiograms, respiratory flow was measured, and inspiratory flow was integrated to produce tidal volume. The crrelation coefficient between the measured and estimated tidal volume was large. The coefficient was influenced by prefiltering, deep breath, position of the subject, and abnormal dederto-cardiograms. Experiments suggested that obstructive sleep apnea could be detected by this method.

Report

(3 results)
  • 1993 Annual Research Report   Final Research Report Summary
  • 1992 Annual Research Report
  • Research Products

    (14 results)

All Other

All Publications (14 results)

  • [Publications] 稲岡秀検: "心電図からの一回換気量推定" 医用電子と生体工学. 30. 183-191 (1992)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] M.Noshiro: "A monitor for tidal volume using the electrocardiogram" Precis.Machin.Incorp.Life Support Tech.4. 115-116 (1993)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] 野城真理: "心電図から呼吸を測る" 青淵. 533. 34-36 (1993)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] 野城真理: "心電図から一回換気量を測る" 病態生理. 13. 144-150 (1994)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] H.Inaoka: "A method for estimating tidal volume from multi-lead electrocardiograms (in Japanese)." Jap.J.Med.Electron.Biol.Eng.30. 183-191 (1992)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] M.Noshiro: "A monitor for tidal volume using the electrocardiograms" Precis.Machin.Incorp.Life Support Tech.4. 115-116 (1993)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] M.Noshiro: "Measuring respiration from electrocardiograms (in Japanese)" Seien. 533. 34-36 (1993)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] M.Noshiro: "Measuring tidal volume from electrocardiograms (in Japanese)" Byotai seriri (Pathological Physiology). 13. 144-150 (1994)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] M.Noshiro: "A monitor for tidal volume using the electrocardiogram." Precis.Machin.Incorp.Life Support Tech.4. 115-116 (1993)

    • Related Report
      1993 Annual Research Report
  • [Publications] 野城真理: "心電図から呼吸を測る" 青淵. 533. 34-36 (1993)

    • Related Report
      1993 Annual Research Report
  • [Publications] 野城真理: "心電図から一回換気量を測る" 病態生理. 13. 144-150 (1994)

    • Related Report
      1993 Annual Research Report
  • [Publications] 稲岡 秀検 他: "心電図を利用して専用センサを不要とする一回換気量計測法" 医用電子と生体工学. 30巻特別号. 571- (1992)

    • Related Report
      1992 Annual Research Report
  • [Publications] 稲岡 秀検 他: "心電図からの一回換気量推定" 医用電子と生体工学. 30. 183-191 (1992)

    • Related Report
      1992 Annual Research Report
  • [Publications] 吉田 行成 他: "心電図利用一回換気量モニタ ー実時間処理用ソフトウェアの開発ー" 31巻特別号. (1993)

    • Related Report
      1992 Annual Research Report

URL: 

Published: 1992-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi