• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

EXPERMENTAL STUDY OF ARTIFICIAL PLACENTA ; DOPPLER ECMO CARDIOGRAPHIC EVALUATION OF GOAT FETAL BLOOD FLOW.

Research Project

Project/Area Number 05671493
Research Category

Grant-in-Aid for General Scientific Research (C)

Allocation TypeSingle-year Grants
Research Field 小児外科
Research InstitutionKOBE UNIVERSITY

Principal Investigator

HISANO Katsuya  KOBE UNIVERSITY.SCHOOL OF MEDICINE.LECTURER, 医学部, 講師 (30135800)

Co-Investigator(Kenkyū-buntansha) OKADA Masayosi  KOBE UNIVERSITY.SCHOOL OF MEDICINE.PROFESSOR, 医学部, 教授 (70030856)
太田 稔明  神戸大学, 医学部, 助手 (80203793)
Project Period (FY) 1993 – 1994
Project Status Completed (Fiscal Year 1994)
Budget Amount *help
¥1,800,000 (Direct Cost: ¥1,800,000)
Fiscal Year 1994: ¥700,000 (Direct Cost: ¥700,000)
Fiscal Year 1993: ¥1,100,000 (Direct Cost: ¥1,100,000)
KeywordsA-V shunt / Artificial placenta / Fetal surgery / Doppler echocardiography / Ductus arteriosus / A-V shunt / fetal surgery / artifical placenta
Research Abstract

An expermental study of fetal incubation in artificial amniotic fluid was performed. Four goat fetuses obtained by caesarian incision (average gestational age was 125 days) underwent cannulation through the umbilical arteries and veins. ECMO circuits contained hollowfiber type membrane oxygenators (0.5 m2)and autoregulating sensors. The fetuses were incubated in an artificial amniotic fluid. A-V shunts were performed by a conventional roller pump until cardiac arrest. The duration of ECMO perfusion ranged from 3 to 70 hours with mean of 40 hours. During ECMO perfusion, ductus arteriosus and fetal ductal blood velocity wave forms were evaluated with pulse Dopple echocardiography. Hemodynamics of the fetus undergoing incubation depended on the perfusion rate of ECMO.On A-V ECMO for fetuses, it was advantageous to obtain a flow rate from 80 to 100 ml/kg/min. Ductal occlusion and stenosis changed the blood velocity wave forms, and caused to early death. Doppler echocardiograpic evaluation was the beat way for assessment of fetal circulation in artificial placenta.

Report

(3 results)
  • 1994 Annual Research Report   Final Research Report Summary
  • 1993 Annual Research Report
  • Research Products

    (6 results)

All Other

All Publications (6 results)

  • [Publications] 久野克也 他: "ヤギ胎仔水中保育実験におけるドップラー超音波法を用いた血行動態の研究" 人工臓器. 22. 880-884 (1993)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1994 Final Research Report Summary
  • [Publications] 坂田雅宏 他: "Color Doppler法によるECMO A-V Bypass下の山羊胎児血流分布の評価" 人工臓器. 23. 921-924 (1994)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1994 Final Research Report Summary
  • [Publications] Hisano K, Okada M, Sakata M, Noma O, Yokoyama N, Uetani Y, Nakamura H: "Experimental study of artificial placenta ; Doppler echocardiographic evaluation of goat fetal bolld flow." Jpn J Artif Organs. 22. 880-884 (1993)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1994 Final Research Report Summary
  • [Publications] Sakata M, Hisano K, Okada M, Yasufuku M, Yokoyama N, Uetani Y, Noma O, Nakamura H: "Experimental study of artificial placenta" Jpn J Artif Organs. 23. 921-924 (1994)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1994 Final Research Report Summary
  • [Publications] 坂田雅宏 他: "Color Doppler法によるECMO A-V Bypass下の山羊胎児血流分布の評価" 人工臓器. 23. 921-924 (1994)

    • Related Report
      1994 Annual Research Report
  • [Publications] 坂田雅宏 他: "Color Duppler法によるECMO A-V Bypass Fの山羊胎児血流分布の評価" 人工臓器. 23 (印刷中). (1994)

    • Related Report
      1993 Annual Research Report

URL: 

Published: 1993-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi