• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

REMOVABLE MAGNETIC KEEPER FREE FROM MRI ARTIFACT

Research Project

Project/Area Number 06671946
Research Category

Grant-in-Aid for General Scientific Research (C)

Allocation TypeSingle-year Grants
Research Field 補綴理工系歯学
Research InstitutionTOKYO MEDICAL AND DENTAL UNIVERSITY

Principal Investigator

NAKAMURA Kazuo  TOKYO MEDICAL AND DENTAL UNIVERSITY,FACULTY OF DENTISTRY,LECTURER, 歯学部, 講師 (90172395)

Co-Investigator(Kenkyū-buntansha) MIZUTANI Hiroshi  TOKYO MEDICAL AND DENTAL UNIVERSITY,FACULTY OF DENTISTRY,LECTURER, 歯学部, 助教授 (00014324)
Project Period (FY) 1994 – 1995
Project Status Completed (Fiscal Year 1995)
Budget Amount *help
¥1,900,000 (Direct Cost: ¥1,900,000)
Fiscal Year 1995: ¥700,000 (Direct Cost: ¥700,000)
Fiscal Year 1994: ¥1,200,000 (Direct Cost: ¥1,200,000)
KeywordsREMOVABLE MAGNETIC KEEPER / DENTAL MAGNETIC ATTACHMENT / MRI / ARTIFACT / ア-ティファクト / 可撤式キ-パ- / 磁性アタッチメント
Research Abstract

Dental magnetic attachments are one of the intraoral atattiments and consist of two parts, the magnetic assembly and the magnetic keeper. Both parts are made by magnetic substances and these materials can cause MRI artifact, when they are used in the imaging field. The magnetic assembly are usually mounted in the prosthesis, so the magnetic assembly are easily kept away from the imaging field by removing the prosthesis. But the keeper is casted within the root cap cemented in the root, and it can be a artifact of the MRI.
The aims of this investigation were to develope the removable magnetic keeper, and to make sure the efficiency of the removable magnetic keeper clinically.
1.Removable magnetic keeper assembly
The removable magnetic keeper assembly consists of a magnetic keeper and a nonmagnetic housing. The magnetic keeper is a disk with a screw-shaped lateral wall or a bolt-shaped disk. The housing is a nut-shaped ring. The magnetic keeper is screwed into the housing and fixed tightly. In the clinical evaluation, the patients was comprised of 28 partially edentulous subjects, 17 women and 11men, provided with dental magnetic attachments with the removable keeper. They were followed up for 0.5-3 years. During this period, none of these removable keepers were dropped out and all of them were kept clean and they coould be easily removed.
2.Influence on MRI
A volunteer test subject with combinations of keepers in lower premolar region was examined by MRI.The images of the magnetic removable keeper and the housing were defective and showed same size of distortion as the ordinary keeper, but the images of the housing only , where the keeper was removed , showed no distortion.

Report

(3 results)
  • 1995 Annual Research Report   Final Research Report Summary
  • 1994 Annual Research Report
  • Research Products

    (2 results)

All Other

All Publications (2 results)

  • [Publications] H.Mizutani,K.Nakamura,et al.: "Influence of Thermal Cycle on Attractive Force of Magnetic Attachment." J Dent Res. 74. 471 (1995)

    • Related Report
      1995 Annual Research Report
  • [Publications] 中村 和夫,水谷 紘,ほか: "磁性合金の補綴領域における応用 第8報 ネオジム磁石を応用した磁性アッタチメント" 日本補綴歯科学会雑誌. 34 94特別号. 139 (1995)

    • Related Report
      1995 Annual Research Report

URL: 

Published: 1994-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI