• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Trial Projection of High Speed Optical Computed-Tomograph using Large Transmitted Light Image

Research Project

Project/Area Number 07558253
Research Category

Grant-in-Aid for Scientific Research (A)

Allocation TypeSingle-year Grants
Section試験
Research Field Biomedical engineering/Biological material science
Research InstitutionHiroshima Prefectural College of Health and Welfare

Principal Investigator

UMEDA Tokuo  Hiroshima Prefectural College of Health and Welfare, Dept. of Radiological Sciences and Technology, Assist. Professor, 放射線技術科学科, 助教授 (40142319)

Co-Investigator(Kenkyū-buntansha) HORINAKA Hiromiti  Univ. of Osaka Prefecture, Faculty of Engineering, Assist, Professor, 工学部, 助教授 (60137239)
OHKE Shigeaki  Setsunan Univ., Faculty of Engineering, Assist. Professor, 工学部, 助教授 (20176853)
SATOMURA Yutaka  Osaka Inst. of Tech., Faculty of Engineering, Assist. Professor, 工学部, 助教授 (00162511)
OSAWA Masahiko  Sumitomo Denko Co., LTD., Bio-Medical Lab., Chairman of an Investigation Committ, バイオメディカル研究部, 主査
INAMURA Kiyonari  Osaka Univ., Faculty of Medicine, Professor, 医学部, 教授 (90203207)
稲本 一夫  大阪大学, 医学部, 教授 (00068446)
Project Period (FY) 1995 – 1996
Project Status Completed (Fiscal Year 1996)
Budget Amount *help
¥5,200,000 (Direct Cost: ¥5,200,000)
Fiscal Year 1996: ¥5,200,000 (Direct Cost: ¥5,200,000)
KeywordsOptical CT / Generation of Degital Medical Image / Uninvation Tomography Device / リアルタイム光CT / 平面透過光像 / 画像再構成 / 無侵襲光CT / 断層像
Research Abstract

Optical computed tomography (Optical CT) has been expected to offer specific diagnostics information on the physiological activities and defects. However, the strong diffusion of light in biological tissues hinders the detection of projection data, i. e. the intensity of light is integrated along straight lines, which is necessary for the CT image reconstruction algorithm currently used for x-ray CT.Several methods have been proposed to detect quasi-straightforward-propagating (QSP) photons of the biological tissue. In our previous research, we investigated the method using light polarization to extract light components traveling along a nearly straight line in a diffused medium.
A method utilizing light polarization was applied to take the projection data of absorbers in a highly scattering medium. The floor level of the projection data due to diffused light was significantly suppressed by detection of photons which preserved initial polarization. An optical CT image was reconstructed from the projection data taken by this method and exhibited higher special resolution than the image reconstructed from the projection data by conventional method.
In summary, it was confirmed that the contrast of projection data for the optical CT was improved by the detection of transmitted light component which preserved the initial polarization as a result of suppression of the diffused light. The optical CT image of two absorbers in the test scattering medium (1.2% aqueous solution of "Intralipid 10%") 75mm thick was reconstructed from the projection data measured by the method using a phase-modulator. The two absorbers were clearly separated in the CT image, but were not separated in that reconstructed from the total transmitted intensity.

Report

(3 results)
  • 1996 Annual Research Report   Final Research Report Summary
  • 1995 Annual Research Report
  • Research Products

    (18 results)

All Other

All Publications (18 results)

  • [Publications] H.Horinaka: "Optical CT Imageing of Absorbers in a Highly Scattering Medium by Detection of Photons Preserving Intial Polarization" Optical Review. 3. 315-317 (1996)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] H.Horinaka: "Optical CT Imageing in Highly Scattering Medium by Extraction of Photons Preserving Initial Polarization" SPIE Techniadl Digest Sumnary. 32-33 (1996)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] 大家重明: "光算波路の実効屈折率に関する一考察" 電気学会・電磁界理論研究会資料. EMT-96-98. 85-93 (1996)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] 里村裕: "光プラズマが励起されたシリコンHガイドにおける漏洩波" 電子情報通信学会,光波マイクロ波相互体用研賢. OMI96-2. (1996)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] Hiromiti, Horinaka: "Optical CT Imaging of Absorbers in a Highly Scattering Medium by Detection of Photons Preserving Initial Polarization" Optical Review. Vol. 3, No. 5. 315-317 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] Hiromiti, Horinaka: "Optical CT Imaging in Highly Scattering Medium by Extraction of Photons Preserving Initial Polarization" International Symposium on Polarization Analysis and Applications to Device Technology, Technical Digest Summary. SPIE. 32-33 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] Shigeaki, Ohke: "A New Integral Expression for the Effective Refractive Index of Optical Waveguides and Its Application to Nonlinear Optical Waveguides" Proceedings of International Laser, Lightwave and Microwave Conference (ILLMC'95). 169-172 (1995)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] Yutaka, Satomura: "Leaky wave Behavior in the Silicon H-guide with Optically Induced Plasma Region" 1996IEEE MTT-S. Tu4B-2. 287-290 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] H.Horinaka: "Optical CT Imaging of Absorbers in a Highly Scattering Medium by Detection of Photous Preserving Initial Polarization" Optical Review. 3,5. 315-317 (1996)

    • Related Report
      1996 Annual Research Report
  • [Publications] H.Horinaka: "Optical CT Imaging in Highly Scattering Medium by Extraction of Photons Presening Initial Polarization" SPIE Tedrnical Digest Summary. 32-33 (1996)

    • Related Report
      1996 Annual Research Report
  • [Publications] 大家 重明: "光導波路の実効屈折率に関する一考察" 電気学会・電磁界理論研究会資料. EMT-96-98. 85-93 (1996)

    • Related Report
      1996 Annual Research Report
  • [Publications] 里村 裕: "光プラズマが励起されたシリコンHガイドにおける漏洩波" 電子情報通信学会,光波マイクロ波相互作用研資. OMI96-2. (1996)

    • Related Report
      1996 Annual Research Report
  • [Publications] 梅田 徳男: "H1S/R1S/PACSのテクロノジ-アセスメント" 日本医用画像工学会誌. 14. 89-96 (1996)

    • Related Report
      1995 Annual Research Report
  • [Publications] 梅田 徳男: "医療情報システムと画像物理工学関係の動向" INNERVISION. 11. 37 (1996)

    • Related Report
      1995 Annual Research Report
  • [Publications] 堀中 博道: "散乱媒質透過光における準直進光成分の抽出法と光CTへの応用" 日本赤外線学会研究会資料. 31-39 (1996)

    • Related Report
      1995 Annual Research Report
  • [Publications] 稲邑 清也: "医用画像の遠隔診断" 画像電子学会誌. 24. 365-371 (1995)

    • Related Report
      1995 Annual Research Report
  • [Publications] 稲本 一夫: "大災害と放射線医療" INNERVISION. 10. 35-36 (1995)

    • Related Report
      1995 Annual Research Report
  • [Publications] 大家 重明: "非線形クラッドを持つ光導波形デバイス" 電子情報通信学会技術速報. OPE95-133. 79-84 (1996)

    • Related Report
      1995 Annual Research Report

URL: 

Published: 1996-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI