• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

THE INFLUENCE OF THE IODINE CONTRAST MEDIUM TO 99m-TcO4 IMAGING

Research Project

Project/Area Number 07671020
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionOITA MEDICAL UNIVERSITY

Principal Investigator

TAKEOKA Hiroshi  OITA MEDICAL UNIVERSITY,MEDICINE,ASSISTANT PROFESSOR, 医学部, 助手 (20253792)

Co-Investigator(Kenkyū-buntansha) UEDA Shinya  OITA MEDICAL UNIVERSITY,MEDICINE,ASSISTANT PROFESSOR, 医学部, 助手 (80223460)
MORI Hiromu  OITA MEDICAL UNIVERSITY,MEDICINE,PROFESSOR, 医学部, 教授 (20128226)
Project Period (FY) 1995 – 1996
Project Status Completed (Fiscal Year 1996)
Budget Amount *help
¥300,000 (Direct Cost: ¥300,000)
Fiscal Year 1996: ¥300,000 (Direct Cost: ¥300,000)
Keywords99m-TcO4 IMAGING / CONTRAST MEDIUM
Research Abstract

There has so far been recognized that the iodine contrast medium had no effect on the thyroid function. Recently we experienced some cases whose thyroid uptake ratio of 99m-TcO4 was decreased after enhanced computed tomography.
The purpose of this study was to determine whether the iodine contrast medium exerted its influence on the thyroid function.
Enhanced CT of the cervical region including the thyroid gland was performed using the iodine contrast medium (about 100ml/body) by intravenous injection. Each patient had normal thyroid function and no abnormal thyroid mass. 99m-TcO4 scintigraphy was performed twice in each patient. Early phase scintigraphy was performed within one week after the enhanced CT and late phase was two weeks after.
The enhanced CT showed no irregular enhancement of the thyroid gland. The scintigraphic images in early and late phase showed no abnormal accumulation in thyroid gland visually, but uptake ratio of 99m-TcO4 in early phase was slightly less than that in the late phase.
As there was no difference in the value of the thyroid hormones between before and after the enhanced CT,it can be said that the iodine contrast medium exerted any influence on the uptake ratio of 99m-TcO4.