• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

ESTABL ISHMENT OF DIELECTRIC SPECTROSCOPY FOR INSTANTANEOUS EVALUATING MYOCARDIAL VIABILITY

Research Project

Project/Area Number 07671458
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Thoracic surgery
Research InstitutionGIFU UNIVERSITY

Principal Investigator

MURAKAWA Shinji (1996)  Gifu univ.school of Med., First dept.of Surg., research associate, 医学部, 助手 (40229977)

不破 誠行 (1995)  岐阜大学, 医学部附属病院, 講師 (90242734)

Co-Investigator(Kenkyū-buntansha) TAKAGI Hisato  Gifu univ.school of Med., First dept.of Surg., reseach associate, 医学部・附属病院, 助手 (50262770)
SASAKI Eisaku  Gifu univ.school of Med., First dept.of Surg., reseach associate, 医学部・附属病院, 助手 (20273138)
MORI Yoshio  Gifu univ.school of Med., First dept.of Surg., reseach associate, 医学部・附属病院, 助手 (40220032)
HIROSE Hajime  Gifu univ.school of Med., First dept.of Surg., professor, 医学部, 教授 (20101272)
村川 真司  岐阜大学, 医学部, 助手 (40229977)
Project Period (FY) 1995 – 1996
Project Status Completed (Fiscal Year 1996)
Budget Amount *help
¥2,300,000 (Direct Cost: ¥2,300,000)
Fiscal Year 1996: ¥200,000 (Direct Cost: ¥200,000)
Fiscal Year 1995: ¥2,100,000 (Direct Cost: ¥2,100,000)
Keywordsdielectric spectroscopy / heart preservation / electrical impedance / cardiac transplantation / left ventricular Emax / myocardial ATP
Research Abstract

The aim of this work is to establish the dielectric spectroscopy for instantaneous evaluating myocardial viability. Canine hearts were immersed in 4゚C saline solution (group S) and 4゚C UW solution (group U) for 8 hours. We measured the peak value of tan delta loss tangent (tan delta m) of myocardium intermittently. In addition, changes of tan delta were compared with changes of myocardial ATP measured every 2 hours. During preservation the change of tan delta m (%tan delta m) correlated well with the change of ATP (%ATP) [group S : r^2=0.81, group U : r^2=0.66].
And we examined whether tan delta couldpredict ventricular contractility after reperfusion. Preserved porcine hearts were immersed in 4゚C saline solution, and tan delta were measured intermittently. Then heterotopic cardiac transplantation followed. During preservation (150 to 360 minutes), the peak value of tan delta (tan delta m) decreased gradually from 5.5(]SY.+-。[)0.5 to 3.8(]SY.+-。[)0.8.Two hours after reperfusion, the tan delta m at the end of preservation was correlated with the percent recovery of left ventricular Emax (%Emax) (r=0.85), while preservation time was not correlated with it (r=0.37). And, changes of tan delta during preservation were compared with myocardial structural changes observed by electron microscopy. The change of tan delta m correlated with the destruction of cellular membrane structure.
Dielectric spectroscopy of myocardium can reflect ischemic injury of cell during preservation. The tan delta m may be useful parameter for evaluation of myocardial viability instantaneously and prediction of the ventricular contractility after reperfusion.

Report

(3 results)
  • 1996 Annual Research Report   Final Research Report Summary
  • 1995 Annual Research Report
  • Research Products

    (16 results)

All Other

All Publications (16 results)

  • [Publications] 石川 真: "電気インピーダンスを用いた単純浸漬保存の保存時間限界の予測に関する実験的研究" 日本胸部外科学会雑誌. 43・9. 1579-1586 (1995)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] Ishikawa M: "Detection of myocardial ischemicinjury during simple coldstorage by measurement of myocardial electrical impedance" The journal of cardiovascular surgery. 37・3. 361-267 (1996)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] Ishikawa M: "Evaluetion of myocardial viability during simple coldstorage with the use of electrical properties in broad frequencies." The journal of heart and lung transplantation. 15・10. 1005-1011 (1996)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] 坂東道哉: "低温単純浸漬保存中の心筋の誘電特性計測による移植後心機能の予測" 岐阜大学医学部紀要. 45・2. 201-206 (1997)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] Ishikawa M: "Noninvasive detection of the limitation of the heart by myocardial electrical impedance." J Jpn Assoc Thorac Surg. 43. 1579-1586 (1995)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] Ishikawa M: "Detection of myocardial ischemic injury during simple cold storage by measurement of myocardial electrical impedance." J Cardiovasc Surg. 37. 261-267 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] Ishikawa M: "Evaluation of myocardial viability during simple cold storage with the use of electrical properties in broad frequencies." J Heart Lung Trasplant. 15. 1005-1011 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] Bando M: "Prediction of ventricular function after transplantation using dielectric analysis of myocardium during hypothermic heart preservation." Acta Sch Med Univ Gifu. 45. 201-206 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] Ishikawa M: "Detection of myocardial ischemicinjury during simple coldstorage by measurement of myocardial electrical impedance" The journal of cardiovascular surgery. 37・3. 261-267 (1996)

    • Related Report
      1996 Annual Research Report
  • [Publications] Ishikawa M: "Evaluation of myocardial viability during simple coldstrage with the use of electrical properties in broadfrequencies." The journal of heart and lung transplantation. 15・10. 1005-1011 (1996)

    • Related Report
      1996 Annual Research Report
  • [Publications] 坂東道哉: "低温単純浸漬保存中の心筋の誘電特性計測による移植後心機能の予測" 岐阜大学医学部紀要. 45・2. 181-185 (1997)

    • Related Report
      1996 Annual Research Report
  • [Publications] Makoto Ishikawa: "Detection of myocardial ischemic injury during simple cold storage by measurement of myocardial impedance." Journal of cardiovascular surgery. (1996)

    • Related Report
      1995 Annual Research Report
  • [Publications] 石川真: "電気インピーダンスを用いた保存心のviability評価法の確立に関する実験的検討." 移植. 29. 127-136 (1994)

    • Related Report
      1995 Annual Research Report
  • [Publications] 石川真: "電気インピーダンスを用いた単純浸漬保存の保存時間限界の予測に関する実験的検討." 日本胸部外科学会雑誌. 43. 1579-1586 (1995)

    • Related Report
      1995 Annual Research Report
  • [Publications] 坂東道哉: "電気的周波数特性の解析による保存中の心筋のviabilityの評価" 医用電子と生体工学. 33 Suppl. 248 (1995)

    • Related Report
      1995 Annual Research Report
  • [Publications] 坂東道哉: "心筋の誘電特性の温度補正についての検討-臨床応用をめざして-" 医用電子と生体工学. 34 Suppl. (1996)

    • Related Report
      1995 Annual Research Report

URL: 

Published: 1995-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi