• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Three dimensional fit and full analysis and three dimensional non-linear finite element analysis of newly designed femoral stems in cementless total hip arthroplasty.

Research Project

Project/Area Number 07671577
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Orthopaedic surgery
Research InstitutionFukui Medical University

Principal Investigator

IMURA Shinichi  Fukui Medical University, Department of Orthopaedic Surgery, Professor, 医学部, 教授 (90019886)

Co-Investigator(Kenkyū-buntansha) OKUMURA Yasuhiro  Fukui Medical University, Department of Orthopaedic Surgery, Assistant, 医学部, 助手 (30204150)
OMORI Hironori  Fukui Medical University, Department of Orthopaedic Surgery, Assistant Professor, 医学部・附属病院, 講師 (70242592)
BABA Hisatoshi  Fukui Medical University, Department of Orthopaedic Surgery, Associate Professor, 医学部, 助教授 (00165060)
Project Period (FY) 1995 – 1996
Project Status Completed (Fiscal Year 1996)
Budget Amount *help
¥1,900,000 (Direct Cost: ¥1,900,000)
Fiscal Year 1996: ¥400,000 (Direct Cost: ¥400,000)
Fiscal Year 1995: ¥1,500,000 (Direct Cost: ¥1,500,000)
Keywordscementless total hip arthroplasty / fit & fill / three-dimensional computer simulation / non linear three-dimensional finite element analysis / relative motion / 相対的変位量 / Fit & Fill
Research Abstract

The fit and fill of the femoral canal are critical to the success of cementless femoral stems in total hip arthroplasty. It is difficult for conventional stems to provide a good fit and fill for the femora of patients with secondary osteoarthritis. We designed two types of Fukui Medical School (FMS) stem with a proximal lateral flare that were different in the medial radius. We compared the fit and fill, the amount of stem-bone relative motions, and load transfer to the femur among the newly designed stems and conventional stems, using a computer simulation and non-linear 3-D finite element (FE) analysis (ADINA6.1 software). The mean proximal fit and total fit of the FMS stems were 46% and 53% respectively, with a significant improvement compared with other stems. The mean fill of FMS stems was 82% at the lower and of the lesser trochanter and 84% at the upper end of the isthmus, which were significantly higher than those of other stems. The FMS showed less proximal lateral relative motion and more load transfer to the proximal femur compared with conventional stem (Omnifit).
It suggests that the FMS will be expected to have a better adaptation of the femur with secondary osteoarthritis and biomechanical stability than conventional stems in early postoperative period.

Report

(3 results)
  • 1996 Annual Research Report   Final Research Report Summary
  • 1995 Annual Research Report
  • Research Products

    (8 results)

All Other

All Publications (8 results)

  • [Publications] Bo A, Imura S, Okumura Y, et al.: "The femoral component for secondary osteoarthritis of the hip joints in Japan" Proceedings of the international symposium on computer and communication systems for imaging guided diagnostics and therapy. 927-932 (1995)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] Omori H, Imura S, Bo A, et al.: "Three-dimensional stress analysis of a newly designed femoral stem for secondary osteoarthritis in noncemented total hip arthroplasty" Proceedings of the international symposium on computer and communication systems for image guided diagnosis and therapy. 867-870 (1996)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] Bo A,Imura S,Okumura Y,Omori H,Ando M,Baba H: "The femoral component for secondary osteoarthritis of the hip joints in Japan." Proc.of CAR. 95. 927-932 (1995)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] Imura S,Tanaka Y,Omori H,Bo A,Ando M: "Durability of the hip prosthesis." J Chubu Rheum.Assoc.27. 90-95 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] Omori H,Imura S,Bo A,Ando M and Baba H: "Three-dimensional stress analysis of a newly designed femoral stem for secondary osteoarthritis in noncemented total hip arthroplasty." Proc.of CAR. 96. 867-870 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1996 Final Research Report Summary
  • [Publications] Bo A,Imura S,Okumura Y,et al.: "The femoral component for secondary osteoarthritis of the hip joints in Japan" Proceedings of the international symposium on computer and communication systems for imaging guided diagnostics and therapy. 927-932 (1995)

    • Related Report
      1996 Annual Research Report
  • [Publications] Omori H,Imura S,Bo A,et al.: "Three-dimensional stress analysis of a newly designed femoral stem for secondary osteoarthritis in noncemented total hip arthroplasty" Proceedings of the international symposium on computer and communication systems for image guided diagnosis and therapy. 867-870 (1996)

    • Related Report
      1996 Annual Research Report
  • [Publications] Bo A,Imura S,Okumura Y,et al.: "The femoral component for secondary osteoarthritis of the hip joints in Japan." Proceedings of the Eighth International Symposium on Computer and Communication Systems for Imaging Guided Diagnostics and Therapy. 927-932 (1995)

    • Related Report
      1995 Annual Research Report

URL: 

Published: 1995-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi