Development of photomechanical sensor for measurement of deposition thickness using optical fiber

Research Project

Project/Area Number 08555061
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section展開研究
Research Field Dynamics/Control
Research InstitutionGifu National College of Technology

Principal Investigator

KUMAZAKI Hironori  Gifu National College of Technology, Department of Electrical Engineering, Associate Professor, 電気工学科, 助教授 (70270262)

Co-Investigator(Kenkyū-buntansha) HANE Kazuhiro  Tohoku University, Department of Mechtronics and Precision Engineering, Professo, 工学部, 教授 (50164893)
INABA Seiki  Gifu National College of Technology, Department of Electrical Engineering, Profe, 電気工学科, 教授 (30110183)
Project Period (FY) 1996 – 1998
Project Status Completed (Fiscal Year 1998)
Budget Amount *help
¥3,100,000 (Direct Cost: ¥3,100,000)
Fiscal Year 1998: ¥500,000 (Direct Cost: ¥500,000)
Fiscal Year 1997: ¥1,000,000 (Direct Cost: ¥1,000,000)
Fiscal Year 1996: ¥1,600,000 (Direct Cost: ¥1,600,000)
Keywordsin-situ deposition thickness measurement / ion sputtering apparatus / optical sensor / quartz core cantilever / サイズ効果
Research Abstract

(1)Fundamental experiments on Au or Ag deposition・・・
The resonance frequencies were measured as a function of the deposition thickness of Au and Ag using a quartz core microcantilever fabricated from an optical fiber in an ion sputtering apparatus. The resonance frequencies monotonously decreased with increase in deposition thickness in both Au deposition and Ag deposition. The rates of decrease were about 0.015% / nm in Au deposition and about 0.009%/nm in Ag deposition. Overall tendencies of experimental values and calculated values applying the theory related to the flexural vibration of a cylindrical composite beam were similar.
(2)Effects of cantilever size・・・
Effects of cantilever size were discussed. Deposition thickness dependence of resonance frequency was measured on three cantilevers with different length and almost the same diameter. Relative rates of resonance frequency shifts of them didn't depend on the length of their cantilevers. Since measurement accuracy for deposition … More thickness is determined by a product of resonance frequency and its relative rate, the length of the cantilever should be shorter in order to obtain a better accuracy.
(3)Automatic measurement of resonance frequency of the cantilever・・・
Automatic measurement of resonance frequency of the cantilever was tried using personal computer which controled the frequency for excitation the cantilever and input vibrating signal. The scattering of resonance frequencies became about 80%. and time required for measurement became shorter compared with former way.
(4)Measurement of deposition thickness by thin glass vibrator installed with micro-ball lens in FC connector・・
Thin glass vibrator deposited Cr and Au was fixed at the tip of PC connector with micro-ball lensin. The resonance frequency as a function of depositon thickness could measured without optical adjustments. Resonance frequency of the glass vibrator with 5mm in length, 2mm in width and 135 mu m in thickness decreased 37Hz from 3.28kHz during deposition of Au 5OOnm. The average rate of resonance frequency shifts was 0.0741Hz/nm in the region.
(5)Deposition thickness measurements for some deposition materials
Resonance frequencies of quartz core cantilevers with almost same size (30mu m in diameter and 2.2mm in length, resonance frequency before deposition was about 5kHz) were measured with deposition thickness of Au, Ag, Mo and Cr. Bigger resonance frequency shift was obtained in case of deposition material with higher density. Resonance frequency shifts were almost caused by only increace in additional mass of the cantilever not the elasticity of deposition materials. Less

Report

(4 results)
  • 1998 Annual Research Report   Final Research Report Summary
  • 1997 Annual Research Report
  • 1996 Annual Research Report
  • Research Products

    (15 results)

All Other

All Publications (15 results)

  • [Publications] H.Kumazaki, S.Inaba and K.Hane: "Deposition thickness sensor for ion sputtering apparatus" T.IEE Japan. 117-E. 105-108 (1997)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1998 Final Research Report Summary
  • [Publications] 熊崎裕教・稲葉成基・羽根一博: "膜厚測定のためのレーザ駆動ファイバコア振動子のサイズ効果" 真空. 40・3. 303-305 (1997)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1998 Final Research Report Summary
  • [Publications] 熊崎裕教・稲葉成基・羽根一博: "ファイバカップリング装着型薄板ガラス振動子を用いた光学式膜厚測定" 真空. 41・3. 164-166 (1998)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1998 Final Research Report Summary
  • [Publications] H.Kumazaki S.Inaba and K.Hane: "Deposition thickness sensor for ion sputtering apparatus" T.IEE Japan.117-E. 105 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1998 Final Research Report Summary
  • [Publications] H.Kumazaki S.Inaba and K.Hane: "Effect of cantilever size of laser-driven fiber core for deposition thickness measurement" J.Vac.Soc.Jpn.40. 303 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1998 Final Research Report Summary
  • [Publications] H.Kumazaki S.Inaba and K.Hane: "Optical measurement for deposition thickness using a thin glass vibrator installed in fiber coupling" J.Vac.Soc.Jpn.41. 165 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1998 Final Research Report Summary
  • [Publications] H.Kumazaki: "Pressure dependence of resonance characteristics of the microcantilever fabricated from optical-fiber" Vacuum. 47・6-8. 475-477 (1996)

    • Related Report
      1997 Annual Research Report
  • [Publications] H.Kumazaki: "Temperature characteristics of vibrating type sensor using micromachined optical fiber-tip" Optical Review. 3・2. 135-138 (1996)

    • Related Report
      1997 Annual Research Report
  • [Publications] H.Kumazaki: "Deposition thickness sensor for ion sputtering apparatus" T.IEE.Japan. 117-E・2. 105-108 (1997)

    • Related Report
      1997 Annual Research Report
  • [Publications] 熊崎裕教: "膜厚測定のためのレーザ駆動ファイバコア振動子のサイズ効果" 真空. 40・3. 303-305 (1997)

    • Related Report
      1997 Annual Research Report
  • [Publications] 熊崎裕教: "FCコネクタ装着型薄板ガラス振動子を用いた光学式膜厚測定" 真空. (印刷中). (1998)

    • Related Report
      1997 Annual Research Report
  • [Publications] H.Kumazaki: "Pressure dependence of resonance characteristics of the microcantilever fabricated from optical fiber" Vacuum. 47・6-8. 475-477 (1996)

    • Related Report
      1996 Annual Research Report
  • [Publications] H.Kumazaki: "Temperature characteristics of vibrating type sensor using micromachined optical fiber-tip" Optical Review. 3・2. 135-138 (1996)

    • Related Report
      1996 Annual Research Report
  • [Publications] H.Kumazaki: "Deposition thickness sensor for ion sputtering apparatus" T.IEE Japan. 117-E・2. 105-108 (1997)

    • Related Report
      1996 Annual Research Report
  • [Publications] 熊崎裕教: "膜厚測定のためのレーザ駆動ファイバコア振動子のサイズ効果" 真空. (印刷中). (1997)