The development of apparatus for bloodless angiography (Bloodless puncture needle and catheter hub/stopcock)

Research Project

Project/Area Number 08671031
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionUniv.of the Ryukyus

Principal Investigator

SAWADA Satoshi  Univ. of the Ryukyus, Department of Radiology, Professor and Chaiman, 医学部, 教授 (80121937)

Co-Investigator(Kenkyū-buntansha) OKUDA Yoshikazu  Univ.of the Ryukyus, Department of Radiology, Assistant, 医学部・附属病院, 助手 (90252866)
TANIGAWA Noboru  Univ.of the Ryukyus, Department of Radiology, Lecturere, 医学部・附属病院, 講師 (90227215)
Project Period (FY) 1996 – 1997
Project Status Completed (Fiscal Year 1997)
Budget Amount *help
¥2,000,000 (Direct Cost: ¥2,000,000)
Fiscal Year 1997: ¥600,000 (Direct Cost: ¥600,000)
Fiscal Year 1996: ¥1,400,000 (Direct Cost: ¥1,400,000)
KeywordsAngiography / Technology / Interventional Radiology
Research Abstract

Purpose : Basic and clinical examinations of a bloodless angio-system using the newly devised vascular entry needle and one-way stopcock were performed.
Materials and methods : The vascular entry needle is made of transparent outer cannula with a tiny membranous window and a built-in counter-reflux valve, and sharp metallic inner stylet with a tip protection sleeve after with drawing. The stopcock/catheter hub is a one-way valve with a built-in duck bill valve. Its basic performance was evaluated, and clinical evaluation was performed.
Results : In the basic and clinical test, very little leakage of blood was observed using the vascular entry needle and stopcock ; thus, it was regarded as a bloodless angiographic examination.
Conclusions : Use of the vascular entry needle and stopcock in angiography caused little leakage of biood, promissing to be an effective way of promissing infection of theoperators.

Report

(3 results)
  • 1997 Annual Research Report   Final Research Report Summary
  • 1996 Annual Research Report
  • Research Products

    (6 results)

All Other

All Publications (6 results)

  • [Publications] 澤田 敏: "無血アンギオシステム:新しい穿刺針とストップコックの開発とその臨床応用" 日本医学放射線学会雑誌. 56-2. S-131-S-131 (1996)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] SAWADA S′: "BLOODLESS ANGIOGRAPHY:THE APPLICATION OF NEWLY DEVISED PUNCTRE NEEDLE AND ONE-WAY STOPCOCK" CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY. 19-SUPPL.1. S-98-S-98 (1996)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] S.Sawada, N,Tanigawa, M.Kobayashi, S.Senda, Y.Okuda, M.Hashimoto, K/Mishima, N.Ohmura: "Bloodless angiography : The application of newly devised punctre needle and one-way stopcock" Cardiovascular and Interventional Radiology. Vol.19 supplement 1. 98-98 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] S.Sawada, M,Kobayashi, N.Tanigawa, T.Senda, Y.Ouda, M,Hashimoto, N.Ohmura, K.Mishima: "Bloodless Angiography system : Newly devised puncture needle and stopcock" 55 th Nihon Igakuhoushasenn Gakkai supplement (Abstract). 131-131 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] 澤田 敏: "無血アンギオシステム:新しい穿刺針とストップコックの開発とその臨床応用" 日本医学放射線学会雑誌. 56-2. S-131-S-131 (1996)

    • Related Report
      1997 Annual Research Report
  • [Publications] SAWADA S: "BLOODLESS ANGIOGRAPHY:THE APPLICATION OF NEWLY DEVISED PUNCTURE NEEDLE AND ONE-WAY STOPCOCK" CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY. 19-SuppL.1. S-98-S-98 (1996)

    • Related Report
      1997 Annual Research Report