• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Image Quality of an Intraoral Storage Phosphor Imaging System for Crinical Setting

Research Project

Project/Area Number 08672172
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field 病態科学系歯学(含放射線系歯学)
Research InstitutionKanagawa Dental College

Principal Investigator

NISHMURA Kousuke  Kanagawa Dental College Dept.of Oral and Maxillofacial Radiology.Assistant Professor, 歯学部, 講師 (30257307)

Co-Investigator(Kenkyū-buntansha) HATSUKI Takahiko  Kanagawa Dental College Dept.of Oral and Maxillofacial Radiology.Instructor, 歯学部, 助手 (40277918)
Project Period (FY) 1996 – 1997
Project Status Completed (Fiscal Year 1997)
Budget Amount *help
¥2,000,000 (Direct Cost: ¥2,000,000)
Fiscal Year 1997: ¥600,000 (Direct Cost: ¥600,000)
Fiscal Year 1996: ¥1,400,000 (Direct Cost: ¥1,400,000)
Keywordsdigital imaging system / imaging plate / computed radiography / intraoral radiography / CRT image / 口内法エックス線撮影
Research Abstract

With the digitalization of information concerning imaging diagnosis, many medical devices for digital imaging have been developed. Digora was developed as a digital imaging system in which an imaging plate (IP) is used as an imaging sensor to obtain images of the oral. Since CRT images are used in such digital imaging systems, we made clinical imaging diagnoses based on CRT images using a Digora system to find an optimal IP,and then we attempted to establish parameters for the evaluation of digital imaging systems in the field of dentistry.
(1) Characteristics of the digital imaging system with IP were examined by enlargement radiography, etc.to determine its usefulness. (2) The imaging format of Digora was converted to the film output for CR,in order to examine the ability of film images in making accurate diagnosis and that of CRT images. (3) The ability of recognizing normal mandibular anatomy was visually compared using a mandibular phantom between CRT images, conventional film imag … More es, and film images obtained with Digora. As a result, no differences were observed between those 3 kinds of images. (4) The ability to detect proximal surface caries did not differ between the 3 kinds of images. (5) The ability to diagnose decalcification of spongy bone did not differ neither between the 3 kinds of images. (6) From the findings described in (2), (3), (4), and (5), it was revealed that oral diseases could be accurately diagnosed using CRT images, indicating the unnecessity of film output. (7) When the ability to diagnose clinical cases (caries, radicular cyst, apical periodontitis, and marginal periodontitis) was compared between CRT images and film images, no difference was observed. (8) When irradiation time was compared among different types of IP in the Digora system (HR for Digora ; ST for general radiography ; UR for electron microscopic radiography), diagnosis could be made using a HR while an irradiation time was shortened to 1/4 that of D speed film, indicating that a dose could be reduced by using a HR.(9) When physical imaging properties of 3 types of IP were examined, a high MTF was obtained with UR whereas HR showed a satisfactory NEQ at a low dose. (10) As overall evaluation on the findings obtained in (8) and (9), an optimal IP in the Digora system for clinical cases was determined to be HR.
We demonstrated the significance of evaluation of image sensors and output images in digital imaging systems and established parameters for the evaluation of digital imaging systems. Less

Report

(3 results)
  • 1997 Annual Research Report   Final Research Report Summary
  • 1996 Annual Research Report
  • Research Products

    (18 results)

All Other

All Publications (18 results)

  • [Publications] 西村 光輔: "Digital Hagnification Radiographyによる骨変化の画像工学的解析" 歯科放射線. 36巻2号. 81-85 (1996)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] 西村 光輔: "口内撮影専用のコンピューテッドラジオグラフィーDigora(〕cp○(/)R〔〕について" 兵庫県歯科医師会機関誌「歯界月報」. 544号. 17-23 (1996)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] 西村 光輔: "Digital Imaging System 「Digora」の臨床応用" 日本歯科評論. 652号. 183-189 (1997)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Jyouji YONEDA: "Image Quality of an Intraoral Storage Phosphor Imaging System for Normal Anatomical Structures,Proximal Caries and Decalciried Sone Charge" Journal of Japanese Society for Oral and Maxillofacial Radiology. Vol.B Nol. 23-34 (1997)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] 西村 光輔: "口腔領域におけるイメージングプレート法X線ディジタル画像の臨床応用に関する研究" INNERVISION. 12巻8号. 60 (1997)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Kousuke NISHIMURA: "Image Analysis of Bone Change using Magnification Radiography." Dental Radiology. 36 (2). 81-85 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Kousuke NISHIMURA: "Computed Radiography 「Digora」 for Intraoral Radiography." The bulletin of Hyogo Dental Association. 544. 17-23 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Kousuke NISHIMURA: "Clinical application of Digital Imaging System 「Digora」" The Nippon Dental Review. 652. 183-189 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Jyouji YONEDA: "Image Quality of an Intraoral Storage Phosphor Imaging System for Normal Anatomical Structures, Proximal Caries and Decalcified Bone Change." Jurnal of Japanese Society for Oral and Maxillofacial Radiology. 13 (1). 23-24 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Kousuke NISHIMURA: "Image Quality of an Intraoral Storage Phosphor Imaging System for Clinical Setting." INNERVISION. 12 : 8. 60 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] 西村光輔: "Digital Magnification Radiographyによる骨変化の画像工学的解析" 歯科放射線. 36巻2号. 81-85 (1996)

    • Related Report
      1997 Annual Research Report
  • [Publications] 西村光輔: "口内撮影専用のコンピューテッドラジオグラフィーDigora^<【○!R】>について" 兵庫県歯科医師会機関誌「歯界月報」. 544号. 17-23 (1996)

    • Related Report
      1997 Annual Research Report
  • [Publications] 西村光輔: "Digital Imaging System「Digora」の臨床応用" 日本歯科評論. 652号. 183-189 (1997)

    • Related Report
      1997 Annual Research Report
  • [Publications] Jyouji YONEDA: "Image Quality of an Intraoral Storage Phosphor Imaging System for Normal Anatomical Structures,Proximal Caries and Decalcified Bone Change." Journal of Japanese Society for Oral and Maxillofacial Radiology. Vol.13 No.1. 23-34 (1997)

    • Related Report
      1997 Annual Research Report
  • [Publications] 西村光輔: "口腔領域におけるイメージングプレート法X線ディジタル画像の臨床応用に関する研究" INNERVISION. 12巻8号. 60 (1997)

    • Related Report
      1997 Annual Research Report
  • [Publications] 西村光輔: "Digital Magnification Radiographyによる骨変化の画像工学的解析" 歯科放射線. 36巻2号. 81-85 (1996)

    • Related Report
      1996 Annual Research Report
  • [Publications] 西村光輔: "口内撮影専用のコンピューテッドラジオグラフィーDigora^<【encircledR】>について" 兵庫県歯科医師会機関誌「歯界月報」. 544号. 17-23 (1996)

    • Related Report
      1996 Annual Research Report
  • [Publications] 西村光輔: "Digital Imaging System「Digora」の臨床応用" 日本歯科評論. 652号. 183-189 (1997)

    • Related Report
      1996 Annual Research Report

URL: 

Published: 1996-04-01   Modified: 2016-04-21  