• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

A STUDY OF RELATIONSHIP BETWEEN DENTURE BASE SIZE AND MOVEMENT

Research Project

Project/Area Number 09470434
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field 補綴理工系歯学
Research InstitutionTOKYO MEDICAL AND DENTAL UNIVERSITTY

Principal Investigator

MIZUTANI Hiroshi  TOKYO MED & DENT UNIV,I^<ST> DEPT OF PROSTHODONTICS ASSOC.PRO, 歯学部, 助教授 (00014324)

Co-Investigator(Kenkyū-buntansha) NAKAMURA Kazuo  TOKYO MED & DENT UNIV,I^<ST> DEPT OF PROSTHODONTICS LECTURER, 歯学部, 講師 (90172395)
Project Period (FY) 1997 – 1998
Project Status Completed (Fiscal Year 1998)
Budget Amount *help
¥2,400,000 (Direct Cost: ¥2,400,000)
Fiscal Year 1998: ¥2,400,000 (Direct Cost: ¥2,400,000)
KeywordsPARTIAL DENTURE / DENTURE MOVEMENT / DENTURE BASE SIZE / MAGNETIC FIELD / MI SENSOR / 部分床義歯 / 義歯床 / 磁場測定
Research Abstract

THE AIM OF THIS STUDY WAS TO ANALYZE THE DENTURE MOVEMENT WITH MEASURING THE MAGNETIC FIELD STRENGTH AND TO MINIMIZE THE DENTURE BASE WITHIN A LIMIT OF ALLOWABLE DENTURE MOVEMENT.AN INSTRUMENT (D-MI) FOR MEASURING THE MAGNETIC FIELD STRENGTH APPLYING MI SENSOR WAS USED IN ORDER TO SURVEY THE DENTURE MOVEMENT.IN CASE WITH USING THE MARKER MAGNETS, THE OUTPUT VOLTAGE VARIED AS A FUNCTION OF DISTANCE BETWEEN THE TARGET AND THE MI SENSOR WITHIN A LIMIT OF O<D<5MM DISTANCE, THE MORE THE DISTANCE INCREASED, THE LOWER THE VOLTAGE WAS.IF THE DISTANCE BETWEEN THE MAGNET AND THE SENSOR WAS FIXED TO 15MM SUPPOSING THE HUMAN SUBJECTS, THE VOLTAGE INCREASED LINEARLY AGAINST THE HORIZONTAL SLIDE ZMM.SECONDARILY, IT WAS EXAMINED WHETHER THE DENTURE MOVEMENT WAS PROPORTIONAL TO THE LEAKED MAGNETIC FIELD PRODUCED BY THE SLIDE BETWEEN THE MAGNETIC ASSEMBLY AND THE KEEPER THE MEASUREMENT WAS PERFORMED ON THE CONDITION THAT THE DISTANCE BETWEEN THE ASSEMBLY AND THE SENSOR WAS FIXED TO 15MM AND THAT THE SLIDE BETWEEN THE ASSEMBLY AND THE KEEPER WAS CHANGED FROM 0MM TO0.5MM.THE RESULTS WERE AS FOLLOWS ; THE STRENGTH OF THE LEAKED MAGNETIC FIELD WAS PROPORTIONAL TO THE SLIDE DISTANCE WITHIN A LIMIT OF 0<D<0.5MM.THE 0.2MV VOLTAGE CHANGE CORRESPONDED TO 0.01MM HORIZONTAL SLIDE.THEREFORE IT WAS CONCLUDED THAT THE STRENGTH OF THE LEAKED MAGNETIC FIELD COULD BE AN INDEX OF THE DENTURE MOVEMENT.FINALLY ONE MAGNETIC DENTURE WEARER WAS USED TO MEASURE THE DENTURE MOVEMENT.THE DENTURE BASE WAS GRADUALLY REDUCED AND RATIO OF DENTURE MOVEMENT WAS CALCULATED.IT WAS CONCLUDED THAT THE SIZE OF THE DENTURE BASE INFLUENCES THE DENTURE MOVEMENT AND PROPER SIZE (NOT TOO EXTENDED AND NOT TOO REDUCED) IS NEEDED TO MINIMIZE THE DENTURE MOVEMENT.

Report

(3 results)
  • 1998 Annual Research Report   Final Research Report Summary
  • 1997 Annual Research Report
  • Research Products

    (9 results)

All Other

All Publications (9 results)

  • [Publications] 水谷 紘: "術者へのアンケートによる磁性アタッチメント使用義歯の追跡調査" 日本補綴歯科学会雑誌. 41(6). 902-909 (1997)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1998 Final Research Report Summary
  • [Publications] 水谷 紘: "磁性アタッチメントを考察する" 補綴臨床. 31(6). 737-745 (1998)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1998 Final Research Report Summary
  • [Publications] H.Mizutani: "Changes of Surf Roughness and Attractive Force of Magnetic Attachment" J.of Dental Research. 77. 799-799 (1998)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1998 Final Research Report Summary
  • [Publications] H.MIZUTANI: "FOLLOW-UP STUDY OF REMOVABLE PARTIAL DENTURE WITH MAGNETIC ATTACHMENT BY QUESTIONAIRE TO DENTIST." J JPN PROSTHODONT SOC. 41. 902-909 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1998 Final Research Report Summary
  • [Publications] H.MIZUTANI: "CHANGES OF SURF ROUGHNESS AND ATTRACTIVE FORCE OF MAGNETIC ATTACHMENT." J.OF DENTAL RESEARCH. 77. 799-799 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1998 Final Research Report Summary
  • [Publications] H.MIZUTANI: "EXAMINATION OF MAGNETIC ATTACHMENT." PRACTICE IN PROSTHODONTICS. 31. 737-745 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1998 Final Research Report Summary
  • [Publications] 水谷 紘: "術者へのアンケートによる磁性アタッチメント使用義歯の追跡調査" 日本補綴歯科学会雑誌. 41(6). 902-909 (1997)

    • Related Report
      1998 Annual Research Report
  • [Publications] 水谷 紘: "磁性アタッチメントを考察する" 補綴臨床. 31(6). 737-745 (1998)

    • Related Report
      1998 Annual Research Report
  • [Publications] H.Mizutani: "Changes of Surf Roughness and Attractive Force of Magnetic Attachment" J.of Dental Research. 77. 799-799 (1998)

    • Related Report
      1998 Annual Research Report

URL: 

Published: 1998-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi