Continuous cardiac output measurements using a newly developed pulmonary artery Doppler catheter combined with intravascular ultrasound tehnique.

Research Project

Project/Area Number 09557126
Research Category

Grant-in-Aid for Scientific Research (B).

Allocation TypeSingle-year Grants
Section展開研究
Research Field Anesthesiology/Resuscitation studies
Research InstitutionGifu University School of Medicine

Principal Investigator

AKAMATSU Shigeru  Gifu University School of Medicine, Assistant Professor, 医学部・附属病院, 講師 (20167828)

Co-Investigator(Kenkyū-buntansha) SAI Takuji  Gifu University School of Medicine, Research Associate, 医学部・附属病院, 助手 (30242720)
UEDA Norio  Gifu University School of Medicine, Research Associate, 医学部・附属病院, 助手 (20223464)
DOHI Shuji  Gifu University School of Medicine, Professor, 医学部, 教授 (40155627)
KONDO Yuji  Aloka Co. Ltd., Senior Engineer, 技術部・課長(研究職)
MATSUNAKA Yoshiyuki  Aloka Co. Ltd., Manager, 技術部・部長(研究職)
近藤 祐司  アロカ(株), 技術部・課長
Project Period (FY) 1997 – 2000
Project Status Completed (Fiscal Year 2000)
Budget Amount *help
¥8,000,000 (Direct Cost: ¥8,000,000)
Fiscal Year 2000: ¥1,400,000 (Direct Cost: ¥1,400,000)
Fiscal Year 1999: ¥1,800,000 (Direct Cost: ¥1,800,000)
Fiscal Year 1998: ¥2,000,000 (Direct Cost: ¥2,000,000)
Fiscal Year 1997: ¥2,800,000 (Direct Cost: ¥2,800,000)
KeywordsCardiac output / Pulmonary artery catheter / Ultrasound / Doppler / Velocity measurements / Monitoring / PA catheter / Cordiac output / Cardiac output / Cardiac Dutput
Research Abstract

Cardiac output is one of the most crucial parameters measured in critically ill patients. The current procedure used to measure cardiac output has been as bolus thermodilution, a technique based on the law of conservation of energy. Although the bolus thermodilution technique is widely accepted as the clinical standard, the technique provides only intermittent information, and the procedure is time-consuming. In critically ill patients, as hemodynamic status may change rapidly, continuous cardiac output monitoring would provide timely information to permit rapid institution and adjustment of therapy. Various technologies for continuous monitoring of cardiac output have been examined by many researchers and clinicians for overa decade.
Measurement of cardiac output using continuous thermodilution technique is technology clinically available. Continuous-thermodilution using pulmonary artery catheter is an injectless system, which incorporates a thermal filament to provide intermittent per … More iods of heat, which is sensed by a distal thermistor. This system provides the average cardiac output over several minutes with a 30-second update. Continuous thermodilution provides acceptable accuracy for clinical situalion, however, it does not provide real-time values. The value indicates the average cardiac output over several minutes, it does not indicate real-time value. Doppler ultrasound techniques have been used for measurement of continuous velocity and, thus, of cardiac output. These techniques are superior in real time basis, however, they suffer from inaccuracy because of their inherent dependency on the angle between the ultrasound beam and the now direction(Doppler angle). Doppler angle would constitute the errors in velocity measurements and in cardiac output measurements. Cardiac output measured by these techniques would not be reliable clinically. So, We have devdoped a new pulmonary artery Doppler catheter, which overcomes this angle dependency, to accurately monitor cardiac output continuously.
Our pulmonary artery Doppler catheter is a modified PA catheter. The catheter has a special lumen for measurement of cross sectional area of pulmonary artery using intravascular ultrasound technique. The catheter was also modified by mounting 2 ultrasound transducer crystals on its distal tip. We combined Doppler ultrasound technique with pulmonary artery catheter, and also combined intravascular ultrasound technique with Doppler ultrasound technique. Thus, cardiac output is able to measure using flow velocity and cross-sectional area of pulmonary artery. A pair of ultrasonic transducers positioned at a fixed angle was mounted on the distal section of pulmonary artery catheter to be positioned in the main pulmonary artery. The Doppler shifts(Δf1, Δf2)were detected by two transducers sampling at closely spaced two points in the main pulmonary artery. The values of Δf1 and Δf2 were used to compute two velocity measurements, and true flow velocity of pulmonary artery was calculated using following equation : V=(V1)^2+(V2)^2)^<1/2>, where V=true velocity, V1 and V2 =velocity detected by the transducer 1 and 2. The velocities were calculated using newly developed phase differential techniques. Cross-sectional area of pulmonary artery was revealed and measured using intravascular ultrasound technique through the special lumen of our pulmonary artery catheter. For the measurements of cross-sectional area of pulmonary artery, intravascular ultrasound technique is more accurate than transthoracic or transecophageal echocardiography. Regarding to continuous cardiac output measurements, after IRB approval, we evaluated the availability of our newly developed pulmonary artery Doppler catheter in animal experiments. We found that cardiac output measured by our newly developed pulmonary artery Doppler catheter gave us accurate value, which could applicable for critically ill patients.
Using a newly developed pulmonary artery Doppler catheter, we are able to continuously measure cardiac output. This technique for continuously measuring cardiac output in real time is superior to other modified thermodilution techniques. Less

Report

(5 results)
  • 2000 Annual Research Report   Final Research Report Summary
  • 1999 Annual Research Report
  • 1998 Annual Research Report
  • 1997 Annual Research Report
  • Research Products

    (34 results)

All Other

All Publications (34 results)

  • [Publications] Ueda N: "Pulmonary arterial and right ventricular responses to prophylactic albumin administration before aortic unclamping during abdominal aortic aneurysmectomy"Anesth Analg. 87・5. 1020-1026 (1998)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Ueda N: "Right ventriular respouses to aortic undamping during arewysmectony"Anesth Analg. 89・2. 531-531 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Akamatsu S: "New technologies in bemodynamic mouitoring"World cougress of Anesthesiologists 2000(Suppl). Suppl・1. 5-6 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Kozawa O: "Peutobarbital brol not nopobol,supross vasopressin stimulated heat shock motein 27 riduction in aortic srooth nuscle cells"Aresthesiology. 92・6. 1807-1813 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Kozawa O: "Enhancement by sphingosire 1-phosphate in vasopressin-induced Phosphornostede hydroeysis in aortic smooth muscle cells. Involuement of P38MAP Kinase"J Cell Biochem. 80・1. 46-52 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Akamatsu S: "coutinous cardiac output measrements with a newly developed polmonay artery Poppler cotheter combined with nitracosalar ultrasand technique"Anesth Analg. (発表予定).

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] 赤松繁: "超音波診断装置・集中治療とClinical Engineering"総合医学社. 7 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] 赤松繁: "臓器蘇生・蘇生・保護と全身管理"真興交易出版社. 15 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Akamatus, S., Kondo, Y., Irie, T., Terazawa, E., Yamamoto T., Ohata H., Kagawa K., Arakawa M.: "Velocity measurement with new Doppler catheter independent of incidence angle."Jpn J Med Ultrasonics. 20(Suppl-1). 207-208 (1993)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Akamatsu, S.: "New technology for echocardiography and Doppler."J Jpn Soc Clin Anesth. 14. 576-579 (1994)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Akamatsu, S., Kondo, Y., Watanabe, Y., Terazawa, E., Dohi, S.: "Flow velocity measurement with a new Doppler catheter independent of angle of incidence."Anesthesiology. 81(Suppl). A570 (1994)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Akamatsu, S., Kondo, Y., Ueda, N., Takeda, T., Dohi, S.: "continuous cardiac output measurements with a newly developed pulmonary artery Doppler catheter."Anesthesiology. 81(Suppl). A515 (1994)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Akamatsu, S., Kondo, Y., Dohi, S.: "Velocity measurements with a new ultrasonic Doppler methods independent of angle of incidence."J Ansth. 10. 133-139 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Akamatsu S.: "Assessment of left ventricular preload using transesophageal echocardiography in critically ill patients."Fluid Metabolism(in Japanese). 14. 28-32 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Ueda, N., Dohi, S., Akamatsu, S., Hamaya, Y., Terazawa, E., Shimonaka, H., Ohata, H.: "Pulmonary Arterial and Right Ventricular responses to Prophylactic albumin administration before Aortic Unclamping during Abdominal Aortic Aneurysmectomy."Anesth Analg. 87(5). 1020-1026 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Ueda N., Dohi S., Akamatsu S.: "Right ventricular response to aotric unclamping during aneurysmectomy."Anesth Analg. 89(2). 531 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Akamatsu S.: "Ultrasound diagnostic equipment for cardiology. Critical Care & Clinical Engineering"Intensive & Critical Care Medicine(in Japanese)pp98-104, Sogo-Igakusya. (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Akamatsu S., Dohi S., Yamamoto T., Kumazawa M., Kitoh H., Ueda N., Terazawa E.: "New technologies in hemodynamic monitoring"World Congress of Anesthesiologist. 2000(Suppl). 5-6 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Ueda N: "Pulmonary arterial and night ventucedor responses to prophylactic albumin administration hefore aortic unclamping during abdominal aortic aneurysmectomy"Anesth Analg. 87・5. 1020-1026 (1998)

    • Related Report
      2000 Annual Research Report
  • [Publications] Ueda N: "Right ventricalac nespouses to antec unclamping during aneurysmectomy"Anesth Analg. 89・2. 531-531 (1999)

    • Related Report
      2000 Annual Research Report
  • [Publications] Akamatsu S: "New technologies in hemodynamic monitoring"Would Congress of Anesthesiologists 2000 (Suppl). Suppl.1. 5-6 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] Kozawa O: "Pentobarbital, but not propobol, supressess vasopressin - stimulated heat shock motein 27 induction in aortic smooth muscle cells."Anesthesiology. 92・6. 1807-1813 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] Kozaura O: "Enhancement by sphingosine l - phosphate in vasopressin - induced phosphoinositide hydrolysis in aortic smooth muscle cells .Involvement of p38 MAP kinase."J Cell Biochem. 80・1. 46-52 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] Akamatsu S: "Continuous coeliac output measurements with a nauly developed pulmonary artery poppler catheter"Anesth Aualg. (発表予定).

    • Related Report
      2000 Annual Research Report
  • [Publications] 赤松繁: "超音波診断装置 集中治療とClimical Engineering"総合医学社. 7 (1999)

    • Related Report
      2000 Annual Research Report
  • [Publications] 赤松繁: "臓器蘇生 蘇生 保護と全身管理"真興交易出版社. 15 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 赤松 繁: "超音波診断装置"集中治療. 11・増. 98-104 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] Ueda N, et al.: "Right ventricular response to aortic unclamping during arecnysmectory."Anesth Z Analg. 89・2. 531-531 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] Kozawa O, et al.: "Pentobarbital, but not propofol suppresses vasopressin-stimulated heat shock protein 27 induction in aortic smooth muscle cells"Anesthesiology. (in press).

    • Related Report
      1999 Annual Research Report
  • [Publications] 赤松 繁: "経食道心エコー図法による周術期左室前負荷の評価" 体液・代謝管理. 14・1. 28-32 (1998)

    • Related Report
      1998 Annual Research Report
  • [Publications] Ueda N,et al: "Pulmonary arterial and right ventricular responses to prophylactic volume loading before aortic unclamping during abdominal aortic aneurysmectomy" Anesth Analg. 87・5. 1020-1026 (1998)

    • Related Report
      1998 Annual Research Report
  • [Publications] 赤松 繁: "超音波ドプラ法による絶対流速測定法と連続的心拍出量測定法への応用" 循環制御. 19. 印刷中 (1998)

    • Related Report
      1997 Annual Research Report
  • [Publications] 赤松 繁: "経食道心エコー図法による週術期左室前負荷の評価" 体液・代謝管理. 14(印刷中). (1998)

    • Related Report
      1997 Annual Research Report
  • [Publications] Ueda N: "Pulmonary arterial and right ventuiular respouses to grophylactie volume loading before aortic unclamping during abdominal aortic anemysinectony" (発表予定).

    • Related Report
      1997 Annual Research Report

URL: 

Published: 1997-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI