• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

In vivo measurement of ocular circulation with the Laser Speakle Method. Development of apparatus and application in ophthalmological research.

Research Project

Project/Area Number 10357016
Research Category

Grant-in-Aid for Scientific Research (A)

Allocation TypeSingle-year Grants
Section展開研究
Research Field Ophthalmology
Research InstitutionTHE UNIVERSITY OF TOKYO

Principal Investigator

ARAIE Makoto  Graduate School of Medicine Faculty University Hospital Sensory and Motor System Medicine, the University of Tokyo, professor, 医学部・附属病院, 教授 (00092122)

Co-Investigator(Kenkyū-buntansha) FUJII Hitoshi  Department of Computer Science and Electronics, Kyusyu Institute of Technology, professor, 情報工学部, 教授 (70133775)
NAGAHARA Miyuki  Graduate School of Medicine Faculty University Hospital Sensory and Motor System Medicine, the University of Tokyo, assistant, 医学部・附属病院, 助手 (50262134)
Project Period (FY) 1998 – 1999
Project Status Completed (Fiscal Year 1999)
Budget Amount *help
¥24,900,000 (Direct Cost: ¥24,900,000)
Fiscal Year 1999: ¥12,000,000 (Direct Cost: ¥12,000,000)
Fiscal Year 1998: ¥12,900,000 (Direct Cost: ¥12,900,000)
KeywordsLaser speckle / Blood velocity / Tissue circulation / Clinical application / Optic. nerve head / Choroid / Retinal vessel
Research Abstract

We have measured the in vivo blood velocity in human retinal veins using a laser speckle system. We also tried to measure whether the normalized blur (NB) value for calculating the retinal venule blood velocity was applicable to the retinal veins near the disc. The NB value, however, had an upper measurement limit. We have constructed a new apparatus for clinical application and also adopted the square blur rate (SBR), a quantitative index of blood velocity, for measuring retinal blood velocity near the disc This system consists of an infrared CCD camera, a monitor display system, a diode laser, an image sensor, and a high speck personal computer including Windows 98-based analyzing system. The funds area, including a target retinal vein, is illuminated with a diode laser through a fundus camera and the laser speckle pattern is imaged onto the area sensor. From the time change of the contrast of the speckle pattern, laser intensity and deviation are calculated using a logic board and the SBR value is also calculated using a personal computer. In an in vitro experiment the SBR obtained from blood flow in a glass capillary tube, used as an analogue of a retinal vein, was correlated with the diameter of the tube, the actual blood flow rate, and the background SBR value, which was used as an analogue of choroidal circulation. In the in vivo experiment the blood velocity in human retinal veins of approximately 150 μm in diameter was estimated in 16 normal human eyes using monograms based on the results of the in vitro experiment. Velocity averaged 18.4 ± 3.8mm/s (mean ± SD, n = 16) in retinal veins of 146 ± 6μm diameter. The coefficient of reproducibility of 2-minute interval measurements was 3.6 ± 0.9 %, and it took 60 ± 11s for one measurement The present methodology is clinically valid for measuring blood velocity in retinal veins.

Report

(3 results)
  • 1999 Annual Research Report   Final Research Report Summary
  • 1998 Annual Research Report
  • Research Products

    (19 results)

All Other

All Publications (19 results)

  • [Publications] 藤居仁: "レーザースペックルグラフィーの原理"新しい眼科. 15(2). 175-180 (1998)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 藤居仁: "新しい眼科用レーザースペックルフローグラフィーシステム"視覚の科学. 19(3). 79-82 (1998)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Miyuki Nagahara: "Real -time blood velocity measurements in human retinal vein using the laser speckle phenomenon."Japanese Journal of Ophthalmology. 43(3). 186-195 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 新家眞: "レーザースペックル法による生体眼循環測定-装置と眼研究への応用-"日本眼科学会雑誌. 103(12). 871-909 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Miyuki Nagahara: "Effects of scleral buckling and encircling procedures on human optic nerve head and retinochoroidal circulation."British journal of opthalmology. 84(1). 31-36 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 氷原幸: "臨床応用可能な網膜血流測定法"血管と内皮. 9(4). 56-67 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Hitoshi Fujii: "Principle of Laser Speckle Flowgraphy"Journal of the Eye. 15-2. 175-180 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Hitoshi Fujii: "New Laser Speckle Flowgraphy for Ophthalmology"Japanese Journal of Visual Science. 19-3. 79-82 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Miyuki Nagahara: "Real-time blood velocity measurements in human retinal vein using the laser speckle phenomenon."Japanese journal of ophthalmology. 43(3). 186-195 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Makoto Araie: "In vivo measurement of ocular circulation with the Laser Speckle Method"J Jpn Ophthalmol Soc. 103(12). 871-909 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Miyuki Nagahara: "Measurement methods in human retinal blood velocity for clinical application."Blood vessel & endotheliun. 9(4). 56-67 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Miyuki Nagahara: "Effects of scleral buckling and encircling procedures on human optic nerve head and retinochoroidal circulation."British journal of ophthalmology. 84(1). 31-36 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Miyuki Nagahara: "Real-time blood velocity measurements in human retinal vein using the laser speckle phenomenon"Japanese Journal of Ophthalmology. 43(3). 186-195 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] 新家 眞: "レーザースペックル法による生体眼循環測定-装置と眼研究への応用-"日本眼科学会雑誌. 103(12). 871-909 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] Miyuki Nagahara: "Effects of scleral buckling and encircling procedures on human optic nerve head and retinochoroidal circulation"British journal of ophthalmology. 84(1). 31-36 (2000)

    • Related Report
      1999 Annual Research Report
  • [Publications] 永原 幸: "臨床応用可能な網膜血流測定法"血管と内皮. 9(4). 56-67 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] 藤居仁: "レーザースペックルフローグラフィーの原理" 新しい眼科. 15・2. 175-180 (1998)

    • Related Report
      1998 Annual Research Report
  • [Publications] 藤居仁: "新しい眼科用レーザースペックルフローグラフィーシステム" 視覚の科学. 19・3. 79-82 (1998)

    • Related Report
      1998 Annual Research Report
  • [Publications] Miyuki Nagahara: "Real-time Measurements of Blood Velocity in Human Retinal Veins Using the Laser Speckle Phenomenon." Japanese Journal of Ophthalmology.(印刷中). (1998)

    • Related Report
      1998 Annual Research Report

URL: 

Published: 1998-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi