Study of Millimeter and Submillimeter wave Catheter for a Irradiation Apparatus

Research Project

Project/Area Number 10470197
Research Category

Grant-in-Aid for Scientific Research (B).

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionKAGAWA MEDICAL UNIVERSITY

Principal Investigator

TATSUKAWA Toshiaki  Kagawa Medical Univ. Phys. Dept. Professor, 医学部, 教授 (00020206)

Co-Investigator(Kenkyū-buntansha) GODA Fuminini  Kagawa Medical Univ. Surgery Dept. Assistant, 医学部, 助手 (90294769)
DOI Akitaka  Kagawa Medical Univ. Phys. Dept. As. Prof., 医学部, 助教授 (00033217)
TERANAKA Masato  Kagawa Medical Univ. Phys. Dept. Assistant, 医学部, 教務職員 (20294770)
IDEHARA Toshitake  Fukui Univ. FIR center Professor, 遠赤外開発研究センタ, 教授 (80020197)
TAKASHIMA Hitoshi  Kagawa Medical Univ. Radiology Dept. As. Prof., 医学部, 助教授 (10116402)
Project Period (FY) 1998 – 2000
Project Status Completed (Fiscal Year 2000)
Budget Amount *help
¥5,100,000 (Direct Cost: ¥5,100,000)
Fiscal Year 2000: ¥1,400,000 (Direct Cost: ¥1,400,000)
Fiscal Year 1999: ¥1,400,000 (Direct Cost: ¥1,400,000)
Fiscal Year 1998: ¥2,300,000 (Direct Cost: ¥2,300,000)
Keywordsradiation apparatus for living body / gyrotron / submillimeter wave / catheter transmission
Research Abstract

In this research project, we have developed a catheter apparatus suitable for irradiation the living bodies using a specially designed gyrotron, GYROTRON FUIV, as a radiation source. The gyrotron is operated in both CW and pulsed regime at middle power TE_<03> and TE_<32> modes with frequencyies 302 GHz and 238 GHz. This is the first application of gyrotrons to radiation apparatus for the living body.
Preliminary measurements on the denaturation distribution and the surface temperature of irradiated samples suggest that they are appropriate for the common radiation apparatus for the living body.
Measurement of the surface temperature of a living rats confirms the normal operation of the radiation apparatus for a cancer. Improvements are underway to enhance the slim catheter waveguide and the narrow focus of submillimeter wave of the antenna to allow localized radiation at still higher frequencies.

Report

(4 results)
  • 2000 Annual Research Report   Final Research Report Summary
  • 1999 Annual Research Report
  • 1998 Annual Research Report
  • Research Products

    (20 results)

All Other

All Publications (20 results)

  • [Publications] T.Tatsukawa et.al.: "Ruby ESR over a wide frequency range in the millimeter wave region"Int.J.Infrared and Millimeter Waves. 19. 859-874 (1998)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] T.Idehara et.al.: "(2)CW operation of a submillimeter wave gyrotron (Gyrotron FU IV)-for high stability of the output frequency"Int.J.on IR and mm Waves. 19. 793-801 (1998)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] T.Idehara et.al.: "(3)Frequency modulation in a submillimeter wave gyrotron"Phys.Rev.Lett.,. 81. 1973-1976 (1998)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] T.Idehara et.al.: "(4)Rapid frequency step-switching in submillimeter wave gyrotrons"Phys.of Plasmas. 6. 2613-2617 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Aripin et.al.: "(5)Submillimeter wave ESR measurement for Cr3+ in ruby crystal using a gyrotron as a radiation source"Int.J.Infrared and Millimeter Waves. 20. 1875-1888 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] T.Tatsukawa et.al.: "(6)Development of submillimeter wave catheter transmitting a gyrotron output for irradiation on living bodies"Int.J.Infrared and Millimeter Waves. 21. 1153-1167 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] T.Tatsukawa, T.Shirai, T.Imaizumi, T.Idehara, I.Ogawa, and T.Kanemaki: "Ruby ESR over a wide frequency range in the millimeter wave region"Int.J.Infrared and Millimeter Waves. 19. 859-874 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] T.Idehara, K.Yoshida, N.Nishida, I.Ogawa, M.Pereyaslavets, and T.Tatsukawa: "CW operation of a submillimeter wave gyrotrons (Gyrotron FU IV) for high stability of the output frequency"Int.J.Infrared and Millimeter Waves. 19. 793-801 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] T.Idehara, M.Pereyaslavets, N.Nishida, K.Yoshida, and I.Ogawa: "Frequency modulation in a submillimeter wave gyrotron"Phys.Rev.Lett.. 81. 1973-1976 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] T.Idehara, Y.Shimizu, I.Ogawa, T.Tatsukawa and G.F.Brand: "Rapid frequency step-switching in submillimeter wave gyrotrons (Gyrotron FU II and FU IV)"Phys. Plasma. 6. 2613-2617 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Aripin, S.Mitsudo, T.Shirai, K.Matsuda, T.Kanemaki, T.Idehara, and T.Tatsukawa: "Submillimeter wave ESR measurement for Cr3+in ruby crystal using a gyrotron as a radiation source"Int.J.Infrared and Millimeter Waves. 20. 1875-1888 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] T.Tatsukawa, A.Doi, M.Teranaka, H.Takashima, F.Goda, T.Idehara, I.Ogawa, S.Mitsudo, and T.Kanemaki: "Development of submillimeter wave catheter transmitting a gyrotron output for irradiation on living bodies"Int.J.Infrared and Millimeter Waves. 21. 1153-1167 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Aripin et.al.: "Submillimeter wave ESR measurement for Cr3+ in ruby crystal using a gyrotron as a radiation source"Int.J.Infrared and Millimeter Waves. 20・11. 1875-1888 (1999)

    • Related Report
      2000 Annual Research Report
  • [Publications] S.P.Sabchevski et.al.: "Computer simulation of axis-encircling beams generated by an electron gun with a permanent magnet system"Int.J.Infrared and Millimeter Waves. 21・9. 1191-1209 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 土井昭孚 等: "ジャイロトロンFU VIによるミリ波・サブミリ波の生体組織に対する照射実験"福井大学遠赤外領域開発研究センター報告書. 1. 150-155 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] T.Tatsukawa et.al.: "Development of submillimeter wave catheter transmitting a gyrotron output for irradiation on living bodies"Int.J.Infrared and Millimeter Waves. 21・8. 1153-1167 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] T.Idehara et.al.: "Nonlinear regime of amplitude modulation in submillimeter wave gyrotrons"Int.J.Infrared and Millimeter Waves. 19・12. 1607-1625 (1998)

    • Related Report
      1999 Annual Research Report
  • [Publications] T.Idehara et.al.: "Rapid frequency step-switching in submillimeter wave gyrotrons"Phys.ofPlasmas. .6. 2613-2617 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] T.Tatsukawa et.al.: "Ruby ESR over a wide frequency range in the millimeter wave region" Int.J.Infrared and Millimeter Waves. 19・6. 859-874 (1998)

    • Related Report
      1998 Annual Research Report
  • [Publications] T.Idehara et.al.: "CW operation of a submillimeter wave gyrotron(Gyrotron FU IV)for high stability of the output frequency" Int.J.Infrared and Millimeter Waves. 19・6. 793-801 (1998)

    • Related Report
      1998 Annual Research Report

URL: 

Published: 1998-04-01   Modified: 2016-04-21  