DEVELOPMENT OF ROSSET-TYPE STERILE WATER SAMPLER FROM DIFFERENT DEPTHS FOR MICROBIOLOGICAL RESEARCH

Research Project

Project/Area Number 10556043
Research Category

Grant-in-Aid for Scientific Research (B).

Allocation TypeSingle-year Grants
Section展開研究
Research Field General fisheries
Research InstitutionOCEAN RESEARCH INSTITUTE, UNIVERSITY OF TOKYO

Principal Investigator

OHWADA Kouichi  OCEAN RESEARCH INSTITUTION, PROFESSOR, 海洋研究所, 教授 (30013585)

Co-Investigator(Kenkyū-buntansha) WADA Minoru  OCEAN RESEARCH INSTITUTE, OCEAN RESEARCH INSTITUTE, UNIVERSITY OF TOKYO RESEARCH ASSOCIATE, 海洋研究所, 助手 (70292860)
NISHIMURA Masahiko  OCEAN RESEARCH INSTITUTE, OCEAN RESEARCH INSTITUTE, UNIVERSITY OF TOKYO RESEARCH ASSOCIATE, 海洋研究所, 助手 (10242174)
KOGURE Kazuhiro  OCEAN RESEARCH INSTITUTE, OCEAN RESEARCH INSTITUTE, UNIVERSITY OF TOKYO ASSOCIATE PROFESSOR, 海洋研究所, 助教授 (10161895)
KAWAKAMI Takashi  CHIEF SCIENTIST, NICHIYU GIKEN KOGYO CO., 第4研究開発部, 課長(研究職)
Project Period (FY) 1998 – 2000
Project Status Completed (Fiscal Year 2000)
Budget Amount *help
¥12,100,000 (Direct Cost: ¥12,100,000)
Fiscal Year 2000: ¥900,000 (Direct Cost: ¥900,000)
Fiscal Year 1999: ¥1,200,000 (Direct Cost: ¥1,200,000)
Fiscal Year 1998: ¥10,000,000 (Direct Cost: ¥10,000,000)
Keywordsmarine microorganisms / ultrasonic wave operation / sterile water sampler / Roset-type / water sampling from different layers
Research Abstract

A very new type of sterile water sampler for microbiological research has been developed. Specificaton for this sampler is as follows ; depth of the use is up to 6,000 m, capable of sampling from 15 different layers, and maximum volume of 1,000 ml. It is composed of onboard facility with ultrasonic generator and transducer, and under water facility with cramp unit, cutter unit, drive unit, pump unit, control unit, generator unit and a all-tight water tank. Ultrasonic wave sent from onboard facility will activate the water sampler and cut the tubing at the water entrance, and then pump unit will suck out water inside the all-tight water tank which will induce ambient water sarnple to introduce into sample bag inside the tank through silicone tubing by negative pressure. Control unit will operate the time for the sampler. This step will be continued at 15 different layers, All the system inside has been sterilized beforehand of course. We have successfully sampled water from surface to 6,000 m during KH-00-1 cruise by R/V Hakuho-maru and KT-00-9 cruise by R/V Tansei-maru.