Development of a portable apparatus in order to indicate the appropriate amount of exercise based on heart rate

Research Project

Project/Area Number 10558142
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section展開研究
Research Field Biomedical engineering/Biological material science
Research InstitutionNagano National College of Technology

Principal Investigator

SAKAGUCHI Masao  Nagano National College of Technology, Dept. of Electronics and Control Eng., Professor, 電子制御工学科, 教授 (70043031)

Co-Investigator(Kenkyū-buntansha) ONO Nobuyuki  Nagano National College of Technology, Dept. of Electronics and Control Eng., Assistant Professor, 電子制御工学科, 助教授 (60214186)
Project Period (FY) 1998 – 1999
Project Status Completed (Fiscal Year 1999)
Budget Amount *help
¥4,500,000 (Direct Cost: ¥4,500,000)
Fiscal Year 1999: ¥2,500,000 (Direct Cost: ¥2,500,000)
Fiscal Year 1998: ¥2,000,000 (Direct Cost: ¥2,000,000)
Keywordsexercise therapy / heart rate / exercise physiology / Karvonen / pedmeter / health science / exercise therapy / heart rate / exercise physiology / Karvonen / pedometer / health science
Research Abstract

Exercise is necessary to maintain good health. We have invented a portable apparatus in order to indicate the appropriate amount of exercise based on the training heart rate. The training heart rate will be calculated from the equation of Karvonen. This training heart rate can be recorded to CF card and analyzed by using personal computer.
The usage of the apparatus will be descried as follows ; Attach the electrocardiogram to the breast of examinee. Input his age, his training ratio, and time. Training ratio will explain how hard the examinee want to exercise, and will be expressed in percentage. Time, here, means for how long he want to exercise. Switch the ENT on, then the examinee starts exercising.. Following three different sounds of buzz refer to the amount of exercises he is taking. 1Hz buzz sound represents for the appropriate amount of exercise. 0.5 Hz buzz appeals that he had taken exercises excessively over the appropriate amount. And 2 Hz buzz means that he had not taken enough amount of exercise.
We have tried a few basic experiment of this apparatus for this presentation. Moreover, on 08 February 2000, we applied for a patent on this apparatus.

Report

(3 results)
  • 1999 Annual Research Report   Final Research Report Summary
  • 1998 Annual Research Report
  • Research Products

    (19 results)

All Other

All Publications (19 results)

  • [Publications] 坂口正雄 他: "健康維持・増進のためのステップマシンによる適正運動量負荷"医用電子と生体工学. 36,Sappl.. 514 (1998)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 坂口正雄 他: "適正運動量指示装置に従った運動量"電子情報通信学会技術研究報告. MBE98-122. 57-61 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 坂口正雄、小野伸幸 他: "適正運動量指示装置の開発とその応用"電子情報通信学会技術研究報告. MBE99-74. 25-30 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 坂口正雄、小野伸幸 他: "携帯型適正運動指示装置"医用電子と生体工学. 投稿中(2000.3).

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 坂口正雄 他: "心拍数記録型適正運動量指示装置の開発"第39回日本エム・イー学会大会. (発表予定).

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 坂口正雄 他: "心拍数記録型適正運動量指示装置に従ったウォーキング"日本エム・イー学会第20回甲信越支部大会(8月). (発表予定).

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Sakaguchi, M., et al.: "The optimum amount of exercise by using a step machine"Jpn. J. Medical electronics and Biological Eng.. 36,Sappl.. 514 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Sakaguchi, M., et al.: "A portable apparatus for indicating of exercise under optimum quantity"Technical Report of IEICE., MBE. 98-122. 57-61 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Sakaguchi, M., et al.: "Development of portable apparatus for indicating of exercise under optimum quantity"IEICE Technical Report., MBE. 99-74. 25-30 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Sakaguchi, M., et al.: "A portable apparatus in order to indicate the appropriate amount of exercise based on the heart rate"Jpn. J. Medical electronics and Biological Eng.. (in press). (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Sakaguchi, M., et al.: "A heart rate record type optimum exercise indicator"The 39th Conference the Japan Society of Medical electronics and Biological Eng.. (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Sakaguchi, M., et al.: "A heart rate record type optimum exercise indicator and its application"The 20th Conference the Japan Society of Medical electronics and Biological Eng., Koh-Sin-Etu. 2000.

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 坂口正雄他: "適正運動量指示装置に従った運動量"電子情報通信学会技術研究報告. MBE98-122. 57-61 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] 坂口正雄,小野伸幸他: "適正運動量指示装置の開発とその応用"電子情報通信学会技術研究報告. MBE99-74. 25-30 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] 坂口正雄: "心拍数記録型適正運動量指示装置"特許 特願2000-030295. 1-20 (2000)

    • Related Report
      1999 Annual Research Report
  • [Publications] 坂口正雄他: "心拍数記録型適正運動量指示装置の開発"第39回日本エム・イー学会大会(5月). (発表予定).

    • Related Report
      1999 Annual Research Report
  • [Publications] 坂口正雄他: "心拍数記録型適正運動量指示装置に従ったウォーキング"日本エム・イー学会第20回甲信越支部大会(8月). (発表予定).

    • Related Report
      1999 Annual Research Report
  • [Publications] 坂口正雄 他: "適正運動量指示装置に従った運動量" 電気情報通信学会技術研究報告. MBE98-122. 57-61 (1999)

    • Related Report
      1998 Annual Research Report
  • [Publications] 坂口正雄,小野伸幸 他: "適正運動量指示装置の開発とその応用" 医用電子と生体工学. 平成11年8月投稿予定.

    • Related Report
      1998 Annual Research Report

URL: 

Published: 1998-04-01   Modified: 2016-04-21  