Project/Area Number |
10559005
|
Research Category |
Grant-in-Aid for Scientific Research (B).
|
Allocation Type | Single-year Grants |
Section | 展開研究 |
Research Field |
広領域
|
Research Institution | THE UNIVERSITY OF TOKYO |
Principal Investigator |
ONAKA Takashi GRADUATE SCHOOL OF SCIENCE THE UNIVERSITY OF TOKYO.ASSOCIATE PROFESSOR, 大学院・理工系研究科, 助教授 (30143358)
|
Co-Investigator(Kenkyū-buntansha) |
TANABE Toshihiko UNIVERSITY OF TOKYO, GRADUATE SCHOOL OF SCIENCE : RESEARCH ASSOCIATE, 大学院・理学系研究科, 助手 (90179812)
KANEDA Hidehiro INSTITUTE OF SPACE AND ASTRONAUTICAL SCIENCE, SPACE ASTROPHYSICS : RESEARCH ASSOCIATE, 宇宙圏研究科, 助手 (30301724)
MURAKAMI Hiroshi INSTITUTE OF SPACE AND ASTRONAUTICAL SCIENCE, SPACE ASTROPHYSICS : PROFESSOR, 宇宙圏研究科, 教授 (40135299)
CHAN Kin-wing UNIVERSITY OF TOKYO, GRADUATE SCHOOL OF SCIENCE : JSPS POSTDOTORIAL FELLOW, 大学院・理学系研究科, 外国人特別研究員
KHONO Tsuguo TOKYO METROPOLITAN INSTITUTE OF TECHNOLOGY, FACULTY OF ENGINNERING : PROFESSOR, 工学部, 教授 (00161878)
KIN?WING Chan 東京大学, 大学院・理学系研究科, 外国人特別研究員
川田 光伸 宇宙科学研究所, 宇宙圏研究科, 助手 (50280558)
|
Project Period (FY) |
1998 – 2000
|
Project Status |
Completed (Fiscal Year 2000)
|
Budget Amount *help |
¥13,400,000 (Direct Cost: ¥13,400,000)
Fiscal Year 2000: ¥1,200,000 (Direct Cost: ¥1,200,000)
Fiscal Year 1999: ¥4,500,000 (Direct Cost: ¥4,500,000)
Fiscal Year 1998: ¥7,700,000 (Direct Cost: ¥7,700,000)
|
Keywords | COOLED TELESCOPE / INFRARED / LIGHT-WEIGHT MIRROR / SPACE-BORNE INSTRUMENTS / SILICON CARBIDE / SPACE OBSERVATION |
Research Abstract |
We have established the process to make a mirror blank of silicon carbide(SiC)porous core and SiC CVD coat based on the measurement of 160mm test mirrors at cryogenic temperatures. We have found that the CVD coat has to be applied on the entire surface of the mirror to prevent the polishing liquid from permeating into the blank. We have confirmed that the mirror made in this way does not show any appreciable deformation even when it is cooled down to liquid helium temperature. We have also examined the effects of the glue and found that it would not make significant problems if the metal part is well treated thermally in advance. We have fabricated a 700mm SiC mirror based on these processes and tested it at liquid helium temperature together with the supporting parts attached. We have found that the non-elastic deformation occurred due to the difference in the coefficients of thermal expansion between the supporting parts(metal)and the mirror at cryogenic temperatures. This will still not make a significant problem for use in infrared wavelengths and we have concluded that the main purpose of the present research has been achieved. However, details of the deformation process, particularly its repeatability, and its effects at room temperature in the adjustment process have to be investigated in detail in next step.
|