• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

A Study of a Quantification of Organs Perfusion with Animal Model Using Nuclear Medicine Technique : Factor of Absorption and Scatter on Gamma-Ray

Research Project

Project/Area Number 10670836
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionKanazawa University

Principal Investigator

ONOGUCHI Masahisa  Kanazawa University, Faculty of Medicine, Assistant, 医学部, 助手 (30283120)

Co-Investigator(Kenkyū-buntansha) TAKAYAMA Teruhiko  Kanazawa University, Faculty of Medicine, Professor, 医学部, 教授 (20171556)
Project Period (FY) 1998 – 1999
Project Status Completed (Fiscal Year 1999)
Budget Amount *help
¥1,200,000 (Direct Cost: ¥1,200,000)
Fiscal Year 1999: ¥600,000 (Direct Cost: ¥600,000)
Fiscal Year 1998: ¥600,000 (Direct Cost: ¥600,000)
KeywordsィイD199mィエD1Tc-tetrofosmin / Myocardial uptake / Planar images / Scintillation counter / Rat / ガンマカメラ / テトロフオスミン / 心筋血流 / 定量 / 吸収 / 散乱線
Research Abstract

It's reported that the duodenum and the small intestine of the activity excreted from the liver and gallbladder can lead to interference with the myocardial uptake. To study how precisely images reflect tracer uptake in a myocardium, as fundamental experiment to examine the influence that accumulation of the liver and alimentary tract (except esophagus) of the activity excreted from the liver gave to the myocardium image in the technetium-99m myocardium perfusion tracer, we administered ィイD199mィエD1Tc-tetrofosmin (following, Tetrofosmin) to a normal rat and compared with measured value obtained by a gamma camera and an actual survey value after the organs extraction. Methods : Thirty-three rats were measured for 5, 10, 15, 30, 45, 60, 90 and 120min after the administration of Tetrofosmin. The accumulated rates for the myocardium, the lung, the liver, the duodenum, the small intestine, the rectum and the blood with a well-type scintillation counter (WC) were assessed as a percentage of t … More he injected dose per gram of tissue (%ID/g). The accumulated rates for each organ with the planar imaging (PI) were assessed as a percentage of the injected dose per pixel (%ID/pixel) establishing regions of interest (ROIs) in each organ. The accumulated rates for each organ, the PI-to-WC ratio and the heart-to-organ ratios calculated by PI and WC were compared. Results : The accumulated rate for the heart with WC increased until 30 min (1.671%±0.306%) after the injection, and subsequently decreased. On the other hand, peak of the accumulated rate with PI was shown at 15 min (1.814%±0.518%) after the injection. Particularly a difference of both was higher in 10 min (PI/WC ratio : about 1.6 times) of the early phase. The accumulated rate for the lung with WC was maximum at 15 min (0.870%±0.312%) after the injection. The accumulated rate with PI, however, showed the maximum value at 10 min (1.139%±0.376%), and a variation of the accumulated rate was hardly recognized 10 min later. The accumulated rate for the liver with WC was hardly shown a marked variance from 5min (0.768%±0.193%) to 30min (0.692%±0.273%), and a tendency of decrease was showed slowly. On the other hand, the accumulated rate with PI was more highly than that with WC in the whole, and high values were showed in 10 min (PI/WC ratio : about 3.3 times) and 15 min (PI/WC ratio : about 2.3 times) in particular. The accumulated rate for the duodenum and the upper small intestine was maximum in 10 min (1.228%±0.602%, 2.245%±1.936%) after the injection, and approximately 90% of ィイD199mィエD1Tc-tetrofosmin were the duodenum excrements. Conclusion : The accumulated rates for each organ with PI were showed higher than that with WC. The difference of both, particularly, was stronger in early phase after the injection. The accumulated rate for the heart with PI was shown significant higher than that with WC at 10 min. The interference of Compton scatter from the liver, duodenum and small intestine was suggested as one of these causes. Less

Report

(3 results)
  • 1999 Annual Research Report   Final Research Report Summary
  • 1998 Annual Research Report
  • Research Products

    (6 results)

All Other

All Publications (6 results)

  • [Publications] 小野口昌久: "ラットにおける心筋四流製剤99mTc-tetrofosminの体内分布―プラナー像と摘出臓器による値の対比―"金沢大学医学部保健学科紀要. 23・2. 47-55 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 小野口昌久: "99mTC-tetrofosmin心筋画像はどの程度真の取り込みを反映しているか?―ラットを用いたガンマカメラによる測定と実測値の対比―"北陸循環核医学研究会記録集. 31. 5-6 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Onoguchi, Masahisa: "Biokinetics of Technetium-99m-Tetrofosmin Myocardial Perfusion Imaging Agent in Rats : Comparison between the Values from Planar Images and Excised Organs"Memoirs Health Sci Med Kanazawa Univ. 23. 47-55 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Onoguchi, Masahisa: "How precisely Myocardial Perfusion images reflect racer uptake? : Comparison between the Values from Planar Images and Excised Organs in Rats"Hokuriku Nuclear Medicine Circulation Conference. 31. 5-6 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 小野口昌久: "ラットにおける心筋血流製剤^<99m>Tc-tetrofosminの体内分布 -プラナー像と摘出臓器による便の対比-"金沢大学医学部保健学科記要. 23・2. 47-55 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] 小野口昌久: "^<99m>Tc-Tetrofosmin心筋画像はどの程度真の取り込みを反映しているか?-ラットを用いたガンマカメラによる測定と実測値の対比-"北陸循環器核医学研究会記録集. 31. 5-6 (1999)

    • Related Report
      1999 Annual Research Report

URL: 

Published: 1998-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi