• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Highly Selective Fluorometric Determination of Polyamines Based on Intramolecular Excimer-Forming Derivatization with a Pyrene-Labeling Reagent

Research Project

Project/Area Number 10672033
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Physical pharmacy
Research InstitutionFukuoka University

Principal Investigator

YAMAGUCHI Masatoshi  Fukuoka Univ., Fac. Pharm. Sci., Prof., 薬学部, 教授 (50117280)

Project Period (FY) 1998 – 1999
Project Status Completed (Fiscal Year 1999)
Budget Amount *help
¥3,700,000 (Direct Cost: ¥3,700,000)
Fiscal Year 1999: ¥1,300,000 (Direct Cost: ¥1,300,000)
Fiscal Year 1998: ¥2,400,000 (Direct Cost: ¥2,400,000)
KeywordsExcimer Fluorescence / Derivatization / Pyrene reagent / HPLC / Polyamine / 高速液体クロマトグラフィー / 蛍光検出
Research Abstract

A highly selective and sensitive method was developed to determine polyamines, based on intramolecular excimer-forming fluorescence derivatization with a pyrene reagent, 4-(1-pyrene) butyric acid N-hydroxysuccinimide ester (PSE), followed by reversed phase high performance liquid chromatography (HPLC). Polyamines having two to four amino moieties in a molecule, were converted to the corresponding dipyrene-to tetrapyrene-labeled derivatives by reaction (100℃ ,20min) with PSE. The derivatives afforded intramolecular excimer fluorescence (450-520 nm) which can clearly be discriminated from monomer (normal) fluorescence (360-420 nm) emitted from PSE, its hydrolysate and monopyrene-labeled derivatives of monoamines. The structures of the derivatives were confirmed by HPLC with mass spectrometry, and the emission of excimer fluorescence could be proved by spectrofluorometry and time-resolved fluorometry. The PSE derivatives of four polyamines [putrescine (Put), cadaverine (Cad), spermidine (Spd) and spermine (Spm)] could be separated by reversed phased HPLC on C8 column with linear gradient elution. The detection limits (signal-to-noise ratio of 3) for the polyamines were 1.0 (Put), 1.0 (Cad), 4.7 (Spd) and 7.0 (Spm) fmol on column. Furthermore, the present method was so selective that biogenic monoamines gave no peak in the chromatogram.

Report

(3 results)
  • 1999 Annual Research Report   Final Research Report Summary
  • 1998 Annual Research Report

URL: 

Published: 1998-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi