• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of evaluation system for dental implant mobility (stability)

Research Project

Project/Area Number 11450162
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field Measurement engineering
Research InstitutionOSAKA DENTAL UNIVERSITY (2001)
Okayama University (1999-2000)

Principal Investigator

SARATANI Keiji (2001)  OSAKA DENTAL UNIVERSITY, DENTISTRY, LECTURER, 歯学部, 講師 (60170817)

岡 久雄 (1999-2000)  岡山大学, 医学部, 教授 (80116441)

Co-Investigator(Kenkyū-buntansha) MITSUDA Takashi  OKAYAMA UNIVERSITY, MEDICAL SCHOOL, ASSISTANT, 医学部, 助手 (30335591)
更谷 啓治  大阪歯科大学, 歯学部, 講師 (60170817)
Project Period (FY) 1999 – 2001
Project Status Completed (Fiscal Year 2001)
Budget Amount *help
¥6,500,000 (Direct Cost: ¥6,500,000)
Fiscal Year 2001: ¥1,100,000 (Direct Cost: ¥1,100,000)
Fiscal Year 2000: ¥1,700,000 (Direct Cost: ¥1,700,000)
Fiscal Year 1999: ¥3,700,000 (Direct Cost: ¥3,700,000)
KeywordsIMPLANT / MOBILITY / OSSEOINTEGRATION / オッセオインテグレーシヲン / 歯科インプラント / 歯の動揺 / インプランテーション / 触診 / Evidence based medicine / 植立評価 / 歯周組織 / インプラントテーション
Research Abstract

We have previously developed an automatic diagnostic system for tooth mobility, for measuring the biomechanical properties of human periodontium. Since the impedance head of the system is too large to measure mobility in an implant abutment and a molar, a simplified testing instrument called T-M tester was developed. A single-frequency vibration is applied to the tooth surface, an acceleration response is measured, and then the mechanical mobility of the priodontium is calculated. The tooth-movement transducer of the probe utilized a set of bimorph piezoelectric ceramic disks. It is therefore small, light, and suitable for oral examination. The basic characteristics of transducer and clinical applicability of the measurement probe are confirmed using an artificial model.
The T-M tester was applied to implants to determine the difference of viscoelastic properties between periodontium and peri-implantium. The obtained results were as follows : it was possible to measure the implant mobility by T-M tester. Mobility-Index scores of the implants were smaller than those of teeth.
We applied the same principle of T-M tester and developed an Implant Movement (IM) checker. In order to obtain the appropriate measuring conditions, we examined the IM checker on natural teeth. Moreover, we verified its performance by using artificial tooth models and implant models. In clinical trials, IM checker was able to evaluate the implant mobility (stability) and long-term change of implant integration.
The newly developed IM checker had sufficient measuring reliability and we could objectively estimate the implant movement in dental clinics.

Report

(4 results)
  • 2001 Annual Research Report   Final Research Report Summary
  • 2000 Annual Research Report
  • 1999 Annual Research Report
  • Research Products

    (12 results)

All Other

All Publications (12 results)

  • [Publications] Hisao OKA: "Development of a dental implant movement checker"岡山大学医学部保健学科紀要. 11. 25-34 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] HISAO OKA et al.: "Development of a dental implant movement checker"Bull Fac. Health Sci, Okayama Univ. Med. Sch.. 11. 25-34 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] H.Oka,K.Ono,S.K.Wijaya,K.Saratani and T.Kawazoe: "Development of a dental implant movement checker"Bull.Fac.Health 2000 Sci.Okayama Univ.Med.Sch.. 11・1. 25-34 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 岡,小野,松谷,龍田,更谷,川添,張,施,王: "デジタル型インプラント動揺測定システムの開発"電子情報通信学会・信学技報. MBE99-157. 73-78 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 岡,小野,松谷,龍田,更谷,川添,施,王: "デジタル型インプラント動揺チェッカーの開発"医用電子と生体工学第39回日本ME学会大会論文集. 38. 296 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] S.K.Wijaya,H.Oka,K.Ikegami,K.Saratani and T.Kawazoe: "Design of a microprocessor based dental implant movement checker"電気・情報関連学会中国支部第51回連合大会講演論文集. 472-473 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] H.Oka,S,K.Wijaya,Y.Matsutani,M.Tatsuta,K.Saratani,T.Kawazoe,M.Zhang,S.Shi and Z.Wang: "Development of IM checker for evaluation of dental implantation"第21回バイオメカニズム学術講演会講演予稿集. 395-398 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 岡,更谷,松谷,龍田,川添,張,施: "チェアサイドで使用可能なインプラント動揺測定装置の開発"第104回日本補綴歯科学会学術大会抄録集. 44. 84 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 岡,小野,松谷,更谷,川添,施,王: "歯科インプラント植立評価のための動揺測定装置の開発"電子情報通信学会・信学技報. MBE99-69. 87-94 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] 更谷,岩田,龍田,川添,岡,小野,施,王: "インプラント動揺測定装置の開発と臨床応用"第16回バイオメカニズム・シンポジウム前刷. 123-130 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] 小野,岡,松谷,龍田,更谷,川添,施,王: "デジタル型インプラント動揺測定システムの開発"2000年IEEE広島学生シンポジウム論文集. 61-62 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] 岡,小野,松谷,龍田,更谷,川添,施,王: "インプラント植立評価のための動揺測定装置の開発"第20回バイオメカニズム学術講演会講演予稿集. 1010-1014 (1999)

    • Related Report
      1999 Annual Research Report

URL: 

Published: 1999-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi