Project/Area Number |
11470187
|
Research Category |
Grant-in-Aid for Scientific Research (B)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
Radiation science
|
Research Institution | National Institute of Radiological Sciences |
Principal Investigator |
IKEHIRA Hiroo National Institute of Radiological Sciences, Dep.Medical Imaging, Head, 医学物理部, 室長 (50150313)
|
Co-Investigator(Kenkyū-buntansha) |
TANADA Shuji National Institute of Radiological Sciences, Dep.Medical Imaging, Director, 医学物理部, 部長 (40116950)
SUHARA Tetsuya National Institute of Radiological Sciences, Dep.Medical Imaging, Director, 医学物理部, 特別上席研究員 (90216490)
OSUGA Toshiaki Chiba University, School of Science, Assistant Professor, 理学部, 助手 (80223816)
IRIE Toshiaki National Institute of Radiological Sciences, Dep.Medical Imaging, Head, 医学物理部, 室長 (40160072)
MURAYAMA Hideo National Institute of Radiological Sciences, Dep.Medical IPhysics, Head, 医学物理部, 室長 (50166310)
田辺 政裕 千葉大学, 医学部・附属病院, 教授 (10207160)
|
Project Period (FY) |
1999 – 2001
|
Project Status |
Completed (Fiscal Year 2001)
|
Budget Amount *help |
¥4,500,000 (Direct Cost: ¥4,500,000)
Fiscal Year 2001: ¥1,400,000 (Direct Cost: ¥1,400,000)
Fiscal Year 2000: ¥1,400,000 (Direct Cost: ¥1,400,000)
Fiscal Year 1999: ¥1,700,000 (Direct Cost: ¥1,700,000)
|
Keywords | NMR / MR microscopy / MRI / special resolution / pulse sequence |
Research Abstract |
It suited pursuing resolution between the high-spatial-resolution of the performance limit in 1999 using the gradient coil of MRI for research of currently possessed, and a highly efficient through rate. Between the high-spatial-resolution of the first year, the concrete achievement target of resolution should be 50 micrometers and the target of the 1st phase was the creation of the spin echo method pulse sequence for achievement and the small volume coil aiming at mouse size are made as an experiment The possibility of resolution was experimentally examined between the further high-spatial-resolution from the result of the S/N measurement and the picture using such hard software. In 2000, high resolution imaging in the equipment for clinical of 1.5T, hybrid equipment was manufactured and adjustment and a check of the practicality were performed the highest of the picture which made the homemade coil for a saddle type MR microscopy and was obtained in the last year using the coil, and the result which resolution became about 30 microns per pixel, and exceeded far the prospective target value of 100 to 50 microns was obtained This resolution is considered from S/N expected by 1.5T, and is presumed to be almost close to a theoretical marginal value. However, high spatial resolution MR image, many problems which contrast, S/N and vibration, and a photographic subject should motion-etc.-solve are left behind future with the equipment for clinical of 1.5T, high spatial resolution by enforcing the optimal pulse sequence for imaging examines the possibility of clinical application furthermore, between the resolution obtained using development of a highly efficient high sensitivity probe, simultaneously pathology data, etc. It is thought that it is necessary perform comparison examination with an high resolution MRI picture and to perform clinical technical evaluation in parallel
|