Study on Prediction of Spinal Cord Injury in Minimally Invasive Endovascular Stent Graft Treatment of Thoracic Aortic Aneurysm

Research Project

Project/Area Number 11557101
Research Category

Grant-in-Aid for Scientific Research (B).

Allocation TypeSingle-year Grants
Section展開研究
Research Field Thoracic surgery
Research InstitutionTokyo Medical University

Principal Investigator

ISHIMARU Shin  Tokyo Medical University Medicine Professor, 医学部, 教授 (50112785)

Project Period (FY) 1999 – 2000
Project Status Completed (Fiscal Year 2000)
Budget Amount *help
¥9,000,000 (Direct Cost: ¥9,000,000)
Fiscal Year 2000: ¥3,600,000 (Direct Cost: ¥3,600,000)
Fiscal Year 1999: ¥5,400,000 (Direct Cost: ¥5,400,000)
Keywordsthoracic aortic aneurysm / spinal cord ischemia / paraplegia / stent graft / endovascular surgery / retrievable stent graft / detachable stent graft system
Research Abstract

Objective : In order to predict spinal cord injury following endovascular stent-graft repair of descending thoracic aortic aneurysms, temporary interruption of the intercostal arteries was performed by placement of a novel retrievable stent graft (Retriever), in the aorta under evoked spinal cord potential (ESCP) monitoring. A detachable stent graft system was newly developed for placement of the permanent stent graft instead of the Retriever.
Methods : The Retriever consisted of self-expandable zigzag stents connected in tandem with longitudinal struts. Each strut was collected in a bundle fixed to a pushing rod. The stent was lined with an ePTFE sheet. Endovascular stent-graft repair of descending thoracic aortic aneurysms was performed in patients with aneurysm located in the middle and distal segment of the descending aorta after obtaining informed consent. The Rehiever was placed temporarily before stent-graft deployment. The Retriever was retracted into the sheath 21 minutes later … More . A stent graft for permanent use was deployed in patients with favorable pre-deployment test results using the Retriever. Mechanical function and safety of a detachable stent graft system were confirmed by a mock circulation with pulsatile flow.
Results : The Retriever was placed in 42 patients. There were no changes in ESCP records obtained before and during Retriever placement. After withdrawal of the Retriever, all aneurysms were excluded by permanent stent grafting. There were no necrologic deficits after stent-graft deployment in any patient. Stent framework was covered by multiple longitudinal struts to achieve efficient movement in the aorta, and connected with the collecting struts by hooks or screws. Stent graft could be detached from the collecting struts and deployed in the correct position.
Conclusions : The pre-deployment test using the Retriever under ESCP monitoring is promising as a predictor of spinal cord ischemia in candidates for stent-graft repair of thoracic aortic aneurysms. A detachable stent graft system is feasible to secure minimally invasive thoracic aortic aneurysm repair by endovascular stent grafting. Less

Report

(3 results)
  • 2000 Annual Research Report   Final Research Report Summary
  • 1999 Annual Research Report
  • Research Products

    (19 results)

All Other

All Publications (19 results)

  • [Publications] Tesuo Miyata: "Endovascular stent graft repair of aortopulmonary fistula"Journal of Vascular Surgery. 29・3. 557-560 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] 川口聡: "胸部大動脈手術後の仮性動脈瘤に対するステントグラフト内挿術による再手術の有用性"日本心臓血管外科学会雑誌. 28・4. 232-236 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] 川口聡: "胸部下行大動脈瘤に対するステントグラフト内挿術における脊髄虚血対策"日本血管外科学会雑誌. 8・3. 412-407 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] 石丸新: "大動脈瘤に対するステント人工血管内挿術・4.ステント人工血管"日本外科学会雑誌. 100・8. 482-485 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] 川口聡: "大動脈瘤の低侵襲治療を目的とした血管内挿型人工血管の実験的研究"日本血管外科学会雑誌. 9・5. 551-559 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Tadashi Fujikawa: "Endovascular Stent Grafting for the Treatment of Blunt Thoracic Aortic Injury"The Journal of TRAUMA. 50・2. 223-229 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] 石丸新: "心臓血管外科"朝倉邦造・朝倉書店. 898 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] T.Miyata: "Endovascular Stent Graft Repair of Aortopulmonary Fistula."J.Vascular Surgery. 29(3). 557-560 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] S.Kawaguchi: "Feasibility of Endovascular Stent Graft Repair for Redo Operation of Pseudo Aneurysms after Thoracic Aortic Surgery."Jpn.J.Cardiovascular Surgery. 28(4). 234-236 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] S.Kawaguchi: "Prediction of Spinal Cord Ischemia with Retrievable Stent Grafts on Endovascular Surgery for Thoracic Descending Aortic Aneurysms."Jpn.J.Vascular Surgery. 8(3). 407-412 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] S.Ishimaru: "Endovascular Stent Grafting of Aortic Aneurysms : 4.Endovascular Stent Graft"J.Japan Surgical Society. 100(4). 234-236 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] S.Kawaguchi: "An Experimental Study of Transluminally Placed Prosthetic Grafts for the Minimally Invasive Treatment of Aortic Aneurysms."Jpn.J.Vascular Surgery. 9(5). 551-559 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] T.Fujikawa: "Endovascular Stent Grafting for the Treatment of Blunt Thoracic Aortic Injury."J.TRAUMA. 50(2). 223-229 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] 川口聡: "大動脈瘤の低侵襲治療を目的とした血管内挿型人工血管の実験的研究"日本血管外科学会雑誌. 9・5. 551-559 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] Tadashi Fujikawa: "Endovascular Stent Grafting for the Treatment of Blunt Thoracic Aortic Injury"The Journal of TRAUMA. 50・2. 223-229 (2001)

    • Related Report
      2000 Annual Research Report
  • [Publications] 川口聡: "胸部大動脈瘤に対するステントグラフトを用いた血管内手術の初期治療成績"脈管学. 40・4. 199-204 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 石丸新: "大動脈疾患に対するステントグラフト内挿術"胸部外科. 54・1. 55-64 (2001)

    • Related Report
      2000 Annual Research Report
  • [Publications] 石丸新: "胸部大動脈に対するステントグラフト治療"集中治療. 12・臨時増刊号. 64-68 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 石丸新: "心臓血管外科"朝倉邦造・朝倉書店. 898 (2000)

    • Related Report
      2000 Annual Research Report

URL: 

Published: 1999-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi