• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of CdZnTe gamma camera for radioguided surgery

Research Project

Project/Area Number 11557142
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section展開研究
Research Field 病態科学系歯学(含放射線系歯学)
Research InstitutionThe Nippon Dental University

Principal Investigator

TSUCHIMOCHI Makoto  The Nippon Dental Univ., school of dentistry at Niigata, Professor, 新潟歯学部, 教授 (20095186)

Co-Investigator(Kenkyū-buntansha) SHIRAHATA Takashi  Acrorad Co. LTD, CEO, 新規開発部門責任者
SAKAHARA Harumi  Hamamatsu University School of Medicine, Professor, 医学部, 教授 (10187031)
HAYAMA Kazuhide  The Nippon Dental Univ., school of dentistry at Niigata, Assistant Professor, 新潟歯学部, 講師 (60120713)
Project Period (FY) 1999 – 2001
Project Status Completed (Fiscal Year 2001)
Budget Amount *help
¥13,200,000 (Direct Cost: ¥13,200,000)
Fiscal Year 2001: ¥1,300,000 (Direct Cost: ¥1,300,000)
Fiscal Year 2000: ¥900,000 (Direct Cost: ¥900,000)
Fiscal Year 1999: ¥11,000,000 (Direct Cost: ¥11,000,000)
Keywordsγcamera / γprobe / CdTe / semiconductor / radioguided surgery / RI detector / sentinel lymph node / RIGS
Research Abstract

Gamma probes have been used for sentinel lymph node biopsy in melanoma and breast cancer. However, gamma probes can only provide radioactivity counts and variable pitch audio output based on the intensity of the detected radioactivity. We have developed a small semiconductor gamma camera (SSGC) that allows the size, shape, and location of the target tissues to be visualized. The purpose of this study is to characterize the performance of the SSGC for radioguided surgery of metastatic lesions and for diagnosing other diseases amenable to the smaller-format associated with this prototype imaging system. Methods & Design : The detector head was comprised of a 32 x 32 Cadmium Telluride semiconductor array and application-specific integrated circuit (ASIC) with a tungsten collimator. The entire assembly was encased in a lead housing measuring 152 mm x 166 mm x 65 mm. The effective visual field was 44.8 mm x 44.8 mm. Two spherical 5 mm diameter Tc-99 m radioactive sources having activities of 0.15 MBq and 100 MBq were used to simulate sentinel lymph nodes and injection site. The relative detectability of these foci was compared using the new detector and a conventional scintillation camera. Use of the prototype was also explored on patients in a variety of clinical applications. Results : The SSGC provided better spatial resolution on phantom studies than the conventional gamma camera control. Both foci could be visualized clearly by the SSGC using a 15-second acquisition time, whereas they could not be readily identified using the conventional system under comparable conditions. Preliminary clinical tests of the SSGC were found to be successful in imaging diseases in a variety of tissues including salivary and thyroid glands, temporomandibular joints, and sentinel lymph nodes. Conclusion : The SSGC has significant potential for use in diagnosing diseases and for facilitating subsequent radioguided surgery.

Report

(3 results)
  • 2001 Annual Research Report   Final Research Report Summary
  • 2000 Annual Research Report
  • Research Products

    (10 results)

All Other

All Publications (10 results)

  • [Publications] 土持 眞: "RIガイド手術のための小型高分解能ガンマカメラ"日本放射線技術学会雑誌. 57・7. 751-758 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] 土持 眞: "術中核医学画像診断機器の開発"映像情報. 33・11. 1038-1046 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] M.TSUCHIMOCHI et al.: "Performance of a Small CdTe Gamma Camera for Radioguided Surgery"PENETRATING RADIATION SYSTEMS AND APPPLICATIONS III. SPIE4508. 74-87 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] Tsuchimochi M.: "Small high resolution gamma camera for radioguided surgery"Japanese Journal of Radiological Technology. Vol.57 No.7. 751-758 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] Tsuchimochi M., Sakahara H., Hayama K., Shirahata T.: "Development of a nuclear imaging device for intraoperative use"Journal of Medical Imaging and Information. Vol.33 No.11. 1038-1046 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] Tsuchimochi M., Sakahara H., Hayama K., Funaki M., Shirahata T., Orskaug T., Maehlum G., Yoshioka K., and Nygard E.: "Performance of a Small CdTe Gamma Camera for Radioguided Surgery"PENETRATING RADIATION SYSTEMS AND APPPLICATIONS III, The International Society for Optical Engineering Volume SPIE 4508. 74-87 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] 土持 眞: "RIガイド手術のための小型高分解能ガンマカメラ"日本放射線技術学会雑誌. 57・7. 751-758 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] 土持 眞: "術中核医学画像診断機器の開発"映像情報. 33・11. 1038-1046 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] M.TSUCHIMOCHI et al.: "Performance of a Small CdTe Gamma Camera for Radioguided Surgery"PENETRATING RADIATION SYSTEMS AND APPLICATIONS III. SPIE 4508. 74-87 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] M.TSUCHIMOCHI et al.: "Development of a New Small High Resolution Gamma Camera for Radioguided Surgery"European Journal of Nuclear Medicine. 27・8. 973 (2000)

    • Related Report
      2000 Annual Research Report

URL: 

Published: 1999-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi