• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Research on minimally invasive therapy of aortic aneurysm using life-size vascular model created from three-dimensional imaging.

Research Project

Project/Area Number 11670879
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionNagoya University

Principal Investigator

ISHIGUCHI Tsuneo  School of Medicine, Nagoya University, Associate Professor, 医学部, 助教授 (70115525)

Project Period (FY) 1999 – 2000
Project Status Completed (Fiscal Year 2000)
Budget Amount *help
¥3,400,000 (Direct Cost: ¥3,400,000)
Fiscal Year 2000: ¥700,000 (Direct Cost: ¥700,000)
Fiscal Year 1999: ¥2,700,000 (Direct Cost: ¥2,700,000)
Keywordsaortic aneurysm / stent-graft / interventional radiology / helical CT / stereolithography / anatomical model / 低侵襲的治療 / 3次元画像 / CT
Research Abstract

PURPOSE : To evaluate the efficacy of life-sized plastic replica of aortic aneurysm using three-dimensional image data for endovascular stent-grafting and to evaluate appropriate devices.
MMATERIALS AND METHODS : Life-sized plastic replicas of thoracic and abdominal aortic aneurysms were produced using 3D helical CT data with laser stereolithography and their accuracy was evaluated. Fort types of stent-grafts with different graft materials were placed in the aneurysm models with different compliances and the intensity of pressure-buffering effect was analyzed. Static ard pulsatile pressures were applied to the stent-grafts to investigate dilatation or deformity.
RESULTS : The sizing error of aortic replicas was less than 0.7mm. Replicas with an elastic material were possible to fabricate. Pressure-buffering effect was prominent when the graft porosity was low and the compliance of the model was high. Stent-graft made of 0.1mm PTFE dilated and deformed under pressure of 200-300 mmHg.
CONCLUSION : The accuracy of replicas of aortic aneurysm using CT data was high and it was useful for treatment planning and simulation. Pressure buffering effect depends on the porosity of graft material and on compliance of aneurysm. When thin PTFE was used, control of blood pressure would be mandatory.

Report

(3 results)
  • 2000 Annual Research Report   Final Research Report Summary
  • 1999 Annual Research Report
  • Research Products

    (19 results)

All Other

All Publications (19 results)

  • [Publications] Tsuneo Ishiguchi, et al: "Endovascular stent-graft deployment : Temporary vena caval occlusion with balloons to control aortic blood flow."Radiology. 215. 594-599 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Kunihiro Maruyama, et al: "Stent-graft placement for pseudoaneurysm of the aorta."Radiation Medicine. 18. 177-185 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] 石口恒男 他: "大動脈ステントグラフトの設計と留置のための画像診断"画像診断. 20. 859-866 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] 石口恒男: "治療に直結する大動脈の画像診断"日本血管造影・Interventional Radiology学会雑誌. 15. 319-323 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Kojioro Suzuki, et al: "Dilatation of stent-grafts by luminal pressures : Experimental evaluation of PTFE and woven polyester grafts"Cardiovascular and Interventional Radiology. (in press). (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Kayoko Kato, et al: "Accuracy of plastic replica of aortic aneurysm using 3D-CT data for transluminal stent-grafting : experimental and clinical evaluation"Journal of Computer Assisted Tomography. (in press). (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Tsuneo Ishiguchi, et al: "Endovascular stent-graft deployment : Temporary vena caval occlusion with balloons to control aortic bllood flow -Experimental canine study and initial clinical experience."Radiology. 215(2). 594-599 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Kunihiro Maruyama, et al: "Stent-graft placement for pseudoaneurysm of the aorta."Radiation Medicine. 18(3). 177-185 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Tsuneo Ishiguchi: "Aortic imaging for endovascular stent-grafting : Evaluation with helical CT and MR angiography."Japanese Journal of Angiography and Interventional Radiology. 15 (3)(in Japanese, English abstract). 319-323 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Akihiko Usui, et al: "Clinical results of an endovascular covered stent-graft via midsternotomy for distal aortic arch aneurysm."Cardiovascular Surgery. 8(7). 545-549 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Kojiro Suzuki, et al: "Dilatation of stent-grafts by luminal pressures : Experimental evaluation of PTFE and woven polyester grafts."Cardiovascular and Interventional Radiology. (in press). (2001)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Kayoko Kato, et al: "Accuracy of plastic replica of aortic aneurysm using 3D-CT data for transluminal stent-grafting : experimental and clinical evaluation."Journal of Computer Assisted Tomography. (in press). (2001)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Tsuneo Ishiguchi, et al: "Endovascular stent-graft deployment : Temporary vena caval occlusion with balloons to control aortic blood flow."Radiology. 215. 594-599 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] Kunihiro Maruyama, et al: "Stent-graft placement for pseudoaneurysm of the aorta."Radiation Medicine. 18・3. 177-185 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 石口恒男 他: "大動脈ステントグラフトの設計と留置のための画像診断"画像診断. 20・8. 859-866 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 石口恒男: "治療に直結する大動脈の画像診断"日本血管造影・Interventional Radiology学会雑誌. 15・3. 319-323 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] Kojioro Suzuki, et al: "Dilatation of stent-grafts by luminal pressures : Experimental evaluation of PTFE and woven polyester grafts"Cardiovascular and Interventional Radiology. (in press). (2001)

    • Related Report
      2000 Annual Research Report
  • [Publications] Kayoko Kato, et al: "Accuracy of plastic replica of aortic aneurysm using 3D-CT data for mtransluminal stent-grafting : experimental and clinical evaluation"Journal of Computer Assisted Tomography. (in press). (2001)

    • Related Report
      2000 Annual Research Report
  • [Publications] Iwai H,Suzuki K,Ishiguchi T.: "Pressure buflering effect of stent-graft."Radiology. 213(P). 476 (1999)

    • Related Report
      1999 Annual Research Report

URL: 

Published: 1999-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI