Development of operation support system and application of clinical education utilizing with newly designed arthroscopy with multiple field and visions

Research Project

Project/Area Number 11672030
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Surgical dentistry
Research InstitutionFukuoka Dental College

Principal Investigator

HONDA Takeshi  Fukuoka dental college, School of dentistry, Professor, 歯学部, 教授 (60099067)

Co-Investigator(Kenkyū-buntansha) TSUTSUMI Sadami  Kyoto university, Frontier medical science, Professor, 再生医科学研究所, 教授 (00028739)
SHIMODA Tsunehisa  Fukuoka dental college, School of dentistry, Associate professor, 歯学部, 助教授 (00216128)
Project Period (FY) 1999 – 2002
Project Status Completed (Fiscal Year 2002)
Budget Amount *help
¥2,800,000 (Direct Cost: ¥2,800,000)
Fiscal Year 2002: ¥100,000 (Direct Cost: ¥100,000)
Fiscal Year 2001: ¥500,000 (Direct Cost: ¥500,000)
Fiscal Year 2000: ¥1,400,000 (Direct Cost: ¥1,400,000)
Fiscal Year 1999: ¥800,000 (Direct Cost: ¥800,000)
Keywordsarthroscope / multiple field of vision / multiple angle / wide view / 3-D information / computer information / support of the operation / learning system
Research Abstract

From the fiscal 1999 to the fiscal 2002, four range vision four apparent tropistic endoscopes of visibility angle 195° (effective length 135mm, scope tube outer diameter 3.0mm, apparent direction angle 67° side apparent and visibility angle 67° ×2, strabismus and visibility angle 100° ×2) and four range vision three apparent tropistic endoscopes of visibility angle 135° (effective length 135.5mm, scope tube outer diameter 2.9mm, apparent direction angle 20° strabismus and visibility angle 100° ×2, visibility angle 95° direct-vision ×1 and contact apparent ×1) were assembled as trial products. What the most difficult point in order to accomplish this research is that the brightness and the resolution of the image were inferior as the result, because the four image guides, the fiber and the walking channel were arranged in the thin tube whose outer diameter 2.9mm - 3.0mm. Furthermore, the prism used in side apparent caused the fact that brightness of the image decreases considerably and that the image reverses. In order to improve the image, the roof type prism which obtains the reflected image was

Report

(5 results)
  • 2002 Annual Research Report   Final Research Report Summary
  • 2001 Annual Research Report
  • 2000 Annual Research Report
  • 1999 Annual Research Report
  • Research Products

    (1 results)

All Other

All Publications (1 results)

  • [Publications] Shimoda-T, Tsutsumi-S, Honda-T: "Development of a new TMJ arthroscope combined with quarlet angle and multiple field of vision"Russian journal of biomechanics. (in press).

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2002 Final Research Report Summary

URL: 

Published: 1999-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi