• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of quaity control system of mammographic X-ray unit to decrease patiant dose in mammography

Research Project

Project/Area Number 11672242
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Medical sociology
Research InstitutionOsaka University

Principal Investigator

MATSUMOTO Masao  Osaka Univ. Med.Sch., Associate Professor, 医学部, 助教授 (50149944)

Co-Investigator(Kenkyū-buntansha) KANAMORI Hitoshi  Fukui Univ.Tech., Dep.Electric Eng., Professor, 工学部, 教授 (70027770)
OGATA Ugi  Osaka Univ.Med Sch., Assistant, 医学部, 助手 (60281127)
Project Period (FY) 1999 – 2000
Project Status Completed (Fiscal Year 2000)
Budget Amount *help
¥3,100,000 (Direct Cost: ¥3,100,000)
Fiscal Year 2000: ¥800,000 (Direct Cost: ¥800,000)
Fiscal Year 1999: ¥2,300,000 (Direct Cost: ¥2,300,000)
KeywordsCdZnTe detector / x-ray spectrum / mammographic x-ray unit / attenuation curve / subject contrast / inherent filter / added filter / CdZnTe半導体検出器
Research Abstract

Our purpose is to directly measure mammographic x-ray spectra with collimators and a low-efficiency CdZnTe detector developed recently and to find out the best fit response function of CdZnTe detector to correct the measured spectra. Photon spectra (target Mo or Rh) produced by a mammographic x-ray unit at 25-32 kV and 240 mAs (=3 times of 80 mAs) and transmitted through 0.03 mm Mo or 0.025 mm Rh filter and object (0.1 mm Al to 0.8 mm Al phantoms) have been analyzed. Since detected spectra were distorted by the response of CdZnTe detector and did not present the true photon spectra, the correction was applied by the stripping procedure. The response function of detector used in this procedure has been determined by the evaluation of interactions (K-escape, coherent scattering, and Compton scattering processes) and incomplete charge collection calculated using the Monte Carlo method. We have used K_<α1>, K_<α2>, K_<β1>, K_<β2> radiations of Cd, Zn, and Te, respectively and have used the weight function for the incomplete charge collection and have considered Compton scattering. The Monte Carlo simulations were continued by changing the important factors (mean path length of hole λ_h, dead layer of the CZT crystal and weight factor W_q) of incomplete charge collection until the best fit response function was found out. Corrected photon spectra were compared with the mammographic x-ray spectral data of Bureau of Radiological Health (BRH) measured using a Ge detector. Attenuation curves of aluminum for 25-32 kV were calculated from the corrected photon spectra and compared with the attenuation curves measured using an ionization chamber. These results obtained using the CdZnTe detector agreed with the mammographic x-ray spectral data of BRH and attenuation curves obtained by the ionization chamber.

Report

(3 results)
  • 2000 Annual Research Report   Final Research Report Summary
  • 1999 Annual Research Report
  • Research Products

    (22 results)

All Other

All Publications (22 results)

  • [Publications] 宮島悟史,森見左近,松本政雄 他1名: "CdZnTe半導体検出器を用いて測定した診断用領域X線スペクトルの補正"医用画像情報学会雑誌. 16. 79-89 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] H.Arimura,H.kubota,M.Matsumoto,他1名: "Proportionality between Wiener spectra of quantum mottle and the squares of modulation transfer functions"Physics in Medicine and Biology. 44. 1337-1352 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] M.Matsumoto,S.Miyajima 他6名: "Correction of some diagnostic X-ray spectra measured using CdZnTe detector"KEK Proceedings 99-8 Radiation Detectors and Their Uses. 99-8. 145-154 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] H.Arimura,T.Data,M.Matsumoto,他3名: "Influence of the scattered X-rays on object sharpness of radiograph"Proceedings of SPIE. 3977. 506-513 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] M.Matsumoto,A.Yamamoto 他3名: "Direct measurement of mammographic X-ray spectra using a CdZnTe detector"Medical Physics. 27. 1490-1502 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] 山本明秀,松本政雄 他4名: "乳房撮影用X線装置の被写体コントラストの解析"医用画像情報学会雑誌. 17. 130-137 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] S.MIYASIMA, S.MORIMI, M.MATSUMOTO et al.: "Correction for x-ray spectra measured with the CdZnTe detecter (Japanese)"J.S.Med.Imag.Into.Scie.. Vol.16-2. 79-89 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] H.Arimura, H.Kuhota, M.Matsumoto et al.: "Proprotionality between Wiener spectra of quantum mottle and the squares of modulation transfer functions."Physics Medicine and Biology. Vol.44. 1337-1352 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] M.Matsumoto, S.Miyajima, et al.: "Correction of Some diagnostic x-ray spectra measured using CdZnTe detector"KEK Proceedings 99-8, Radiation Detectors and Their Uses. Vol.99-8. 145-154 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] H.Arimura, T.Date, M.Matsumoto, et.al.: "Influence of the scattered x-rays on object sharpness of radiograph"Proceedings of SPIE. Vol.3977. 506-513 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] M.Matsumoto, A.Yamamoto et.al.: "Direct measurement of mammographic x-ray spectra using a CdZnTe detector"Medical Physics. Vol.27-7. 1490-1502 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] A.Yamamoto, M.Matsumoto, et.al.: "Analysis of subject contrasts on mammographic X-ray units measured with a CdZnTe detector (Japanese)"J.S.Med.Imag.Inf.Scie.. Vol.17-3. 130-137 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] 松本政雄,稲邑清也: "フラットパネルディテクタの物理特性について"医学物理. 20・Supp.No.1. 17-42 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 山崎隆治,隅田伊織,松本政雄 他6名: "CT装置の一次X線スペクトルの解析"医用画像情報学会雑誌. 17・2. 88-96 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] M.Matsumoto,A.Yamamo to et.al: "Direct measurement of mammographic X-ray spectra using a CdZnTe detector"Medical Physics. 27・7. 1490-1502 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 松本政雄 他6名: "間接型フラットパネルディテクタの物理特性の測定"日本写真学会誌. 63・4. 210-216 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 山本明秀,松本政雄 他4名: "乳房撮影用X線装置の被写体コントラストの解析"医用画像情報学会雑誌. 17・3. 130-137 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 宮島悟史,森見左近,松本政雄,金森仁志: "CdZnTe 半導体検出器を用いて測定した診断領域X線スペクトルの補正"医用画像情報学会雑誌. 16・2. 79-89 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] 宇山親雄,松本政雄,他8名: "Proposal for medical application beamlines of the Spring-8"Proceedings of SPIE. 3770. 193-204 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] 松本政雄,金森仁志,他3名: "Correction of some diagnostic X-ray spectra measured using CdZnTe detector"Abstract of 11th International Congress of Radiation Research. 1. 295 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] 松本政雄,金森仁志,他5名: "Some diagnostic X-ray spectra and exposure attenuation curres measured using CdZnTe detector"Japanese Journal of Medical Physics [Supplement 61]. 19. 392-395 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] 有村秀孝、窪田英明,松本政雄,金森仁志: "Proportionality between Wiener spectra of quantum mottle and the squares of modulation transfer function"Physics in Medicine and Biology. 44. 1337-1352 (1999)

    • Related Report
      1999 Annual Research Report

URL: 

Published: 1999-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI