• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Fundamental examination of the detection of sentineal lymph node by MR lymphography

Research Project

Project/Area Number 12470190
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionGrant-in-Aid for Scientific Research (B) (2)

Principal Investigator

SHIMADA Morio  Toho University the 1st Department of Radiology Lecturer, 医学部, 講師 (20196489)

Co-Investigator(Kenkyū-buntansha) TERAMOTO Ryusei  Toho University the 1st Department of Radiology Professor, 医学部, 教授 (00146713)
FUNAHASHI Kimihiko  Toho University the 1st Department of Radiology Lecturer, 医学部, 講師 (90297698)
HAYASHI Sanshin  Toho University the 1st Department of Radiology Professor, 医学部, 教授 (50010252)
INOUE Yusuke  The Institute of Medical Science The university of Tokyo the Department of Radiology Lecturer, 医科研部, 講師 (40232566)
YOSHIKAWA Kohki  The institute of Medical Science The university of Tokyo the Department of Radiology Assistant professor, 医科研, 助教授 (10272494)
Project Period (FY) 2000 – 2002
Project Status Completed (Fiscal Year 2002)
Budget Amount *help
¥7,500,000 (Direct Cost: ¥7,500,000)
Fiscal Year 2002: ¥2,000,000 (Direct Cost: ¥2,000,000)
Fiscal Year 2001: ¥2,300,000 (Direct Cost: ¥2,300,000)
Fiscal Year 2000: ¥3,200,000 (Direct Cost: ¥3,200,000)
KeywordsMR / Contrast Agent / Lymph nocle / Undofluorise 8 / Metastases / Lymph nocle / SPIO / Metastasses / MRI / gadofluorine 8 / Gd-DTPA / Rat study / Gd-EOB-DTPA / Gd-BOPTA / animal study / VX2 tumor
Research Abstract

We evaluated the usefulness of Gadofluorine 8(G8) and Gd-DTPA for interstitial MR Lymphography (MRL)
Materials: Phantom imaging studies were conducted with G8 and Gd-DTPA corresponding to 0.1-0.005 μmolGd/ml and SI (signal intensity) was measured. Popliteal lymph mode (PLN) accumulation was investigated in the rabbits. Imaging performed before and after administration of G8 (50μmolGd/ml) and Gd-DTAP (50μmolGd/ml) subcutaneously. CER measurements of PLN were determined both prior to and following the administration
Results: SI of phantom for G8 are higher than those for Gd-DTAP from 0.1 to 0.002 μmol/Gd/ml (p<0.0001). Imaging after 5 min can clearly detect PLN accumulation on two contrast agents. Nevertheless, PLN accumulation of Gd-DTAP disappeared after about 30min. A statistically significant difference between G8 and Gd-DTPA can be seen from 5 to 90 min in CER (p<0.0001)
PLN became visible clearly at 5 min after the injection of G8 and Gd-DTAP, Nevertheless, PLN accumulation of Gd-DTAP disappeared at 30 min. Otherwise, PLN accumulation of G8 continued up to 90 min
Conclusion: These studies indicated that G8 was more suitable than Gd-DTAP as a contrast agent for interstitial MRL up to 90min

Report

(4 results)
  • 2002 Annual Research Report   Final Research Report Summary
  • 2001 Annual Research Report
  • 2000 Annual Research Report
  • Research Products

    (9 results)

All Other

All Publications (9 results)

  • [Publications] 嶋田守男, 吉川宏起: "磁気共鳴リンパ管造影によるsentinel lymphnodeの検出能の基礎的検討"INNERVISION. 17-8. 34-34 (2002)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] 吉川宏起, 井上優介: "新しいMR造影剤"月磁医読. 20(6). 302-318 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] 林 三進: "3D MR lymphangiographyによる胸管画像の解析"臨床放射線. 46(1). 8-13 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] M. Shimada, K. Yoshikawa, Y. Inoue: "Fundamental examination of the detection of sentineal lymph node by Mr lymphography"INNERVISION. 17-8. 134-134 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] Kohki Yoshikawa: "New Contract Agents for MR Imagrj"JMR. 20(6). 302-318 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] S Hayashi: "Analysis of the thematic duct imaging by 3D MR lymphangiography without contract agent"Jpn J Clin Radiol. 46(1). 8-13 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] 嶋田守男, 吉川宏起, 井上優介: "磁気共鳴リンパ管造影によるsentinel lymphnodeの検出能の基礎的検討"INNERVISION. 17-8. 34-34 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 嶋田守男, 木暮 喬, 吉川宏起: "食道がんのリンパ節転移-CT,MRI,EUSの現状と新しいMRI造影剤ならびにPET診断によるリンパ節転移診断の可能性-"21世紀の消化管がんの内科治療. 20-26 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] 吉川宏起,井上優介,吉岡直紀,嶋田守男,林三進: "新しいMRI造影剤"日磁医誌. 20(6). 302-318 (2000)

    • Related Report
      2000 Annual Research Report

URL: 

Published: 2000-04-01   Modified: 2016-04-21  