• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Basic research on a 3D CT system using a CCD sensor for Oral Maxillofacial region

Research Project

Project/Area Number 12470398
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field 病態科学系歯学(含放射線系歯学)
Research InstitutionKyushu University

Principal Investigator

KANDA Shigenobu  Kyushu University, Department of Oral and Maxillofacial Radiology, Faculty of dental Science, Professor, 大学院・歯学研究院, 教授 (20014003)

Co-Investigator(Kenkyū-buntansha) OHKI Masafumu  Kyushu University, School of Health Sciences, Faculty of Medicine, Professor, 医学部保健学科, 教授 (10160441)
TOYOFUKU Fukai  Kyushu University, School of Health Sciences, Faculty of Medicine, Professor, 医学部保健学科, 教授 (10117179)
TOKUMORI Kenji  Kyushu University, Department of Oral and Maxillofacial Radiology, Faculty of dental Science, Research associate, 大学院・歯学研究院, 助手 (40253463)
KAWAZU Toshiyuki  Kyushu University, Department of Oral and Maxillofacial Radiology, Faculty of dental Science, Research associate, 歯学部附属病院, 助手 (20294960)
TANAKA Kakemasa  Kyushu University, Department of Oral and Maxillofacial Radiology, Faculty of dental Science, Research associate, 歯学部附属病院, 助手 (30163538)
Project Period (FY) 2000 – 2002
Project Status Completed (Fiscal Year 2002)
Budget Amount *help
¥13,700,000 (Direct Cost: ¥13,700,000)
Fiscal Year 2002: ¥2,900,000 (Direct Cost: ¥2,900,000)
Fiscal Year 2001: ¥5,700,000 (Direct Cost: ¥5,700,000)
Fiscal Year 2000: ¥5,100,000 (Direct Cost: ¥5,100,000)
KeywordsCCD sensor / CT
Research Abstract

To investigate problems for developing a 3D CT system using a pinhole CCD sensor, 1) a simulation p program, 2) a reconstruction program, 3) a control system for four stepping motor and 4) a CCD control system were developed. By using the simulation program (1), numerical 2D projection data were obtained. The reconstruction images for the data were calculated by using the reconstruction program (2). These results made it possible to evaluate the propriety of the simulation program and the reconstruction program. The control system for four stepping motor (3) made it possible to control up to 4-axis moving. By developing the CCD control system, we could obtain direct projection images. Using all these developed programs and systems, tomographic images, the center of which was above the images obtained by a CCD sensor, could be obtained without problems. However, there is a problem to be left. The insufficient of the x-ray photons made it difficult to obtain the projection using a pinhole CCD sensor. We have to improve this problem in the future.

Report

(4 results)
  • 2002 Annual Research Report   Final Research Report Summary
  • 2001 Annual Research Report
  • 2000 Annual Research Report

URL: 

Published: 2000-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI