Project/Area Number |
12470398
|
Research Category |
Grant-in-Aid for Scientific Research (B)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
病態科学系歯学(含放射線系歯学)
|
Research Institution | Kyushu University |
Principal Investigator |
KANDA Shigenobu Kyushu University, Department of Oral and Maxillofacial Radiology, Faculty of dental Science, Professor, 大学院・歯学研究院, 教授 (20014003)
|
Co-Investigator(Kenkyū-buntansha) |
OHKI Masafumu Kyushu University, School of Health Sciences, Faculty of Medicine, Professor, 医学部保健学科, 教授 (10160441)
TOYOFUKU Fukai Kyushu University, School of Health Sciences, Faculty of Medicine, Professor, 医学部保健学科, 教授 (10117179)
TOKUMORI Kenji Kyushu University, Department of Oral and Maxillofacial Radiology, Faculty of dental Science, Research associate, 大学院・歯学研究院, 助手 (40253463)
KAWAZU Toshiyuki Kyushu University, Department of Oral and Maxillofacial Radiology, Faculty of dental Science, Research associate, 歯学部附属病院, 助手 (20294960)
TANAKA Kakemasa Kyushu University, Department of Oral and Maxillofacial Radiology, Faculty of dental Science, Research associate, 歯学部附属病院, 助手 (30163538)
|
Project Period (FY) |
2000 – 2002
|
Project Status |
Completed (Fiscal Year 2002)
|
Budget Amount *help |
¥13,700,000 (Direct Cost: ¥13,700,000)
Fiscal Year 2002: ¥2,900,000 (Direct Cost: ¥2,900,000)
Fiscal Year 2001: ¥5,700,000 (Direct Cost: ¥5,700,000)
Fiscal Year 2000: ¥5,100,000 (Direct Cost: ¥5,100,000)
|
Keywords | CCD sensor / CT |
Research Abstract |
To investigate problems for developing a 3D CT system using a pinhole CCD sensor, 1) a simulation p program, 2) a reconstruction program, 3) a control system for four stepping motor and 4) a CCD control system were developed. By using the simulation program (1), numerical 2D projection data were obtained. The reconstruction images for the data were calculated by using the reconstruction program (2). These results made it possible to evaluate the propriety of the simulation program and the reconstruction program. The control system for four stepping motor (3) made it possible to control up to 4-axis moving. By developing the CCD control system, we could obtain direct projection images. Using all these developed programs and systems, tomographic images, the center of which was above the images obtained by a CCD sensor, could be obtained without problems. However, there is a problem to be left. The insufficient of the x-ray photons made it difficult to obtain the projection using a pinhole CCD sensor. We have to improve this problem in the future.
|