Navigation system for endoscope

Research Project

Project/Area Number 12480263
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field Biomedical engineering/Biological material science
Research InstitutionOsaka University

Principal Investigator

TAMURA Shinichi  Osaka University Graduate School of Medicine, Professor, 医学系研究科, 教授 (30029540)

Co-Investigator(Kenkyū-buntansha) TAMAKI Yasuhiro  Osaka University Graduate School of Medicine, Associate Professor, 医学系研究科, 助教授 (10273690)
KATO Amami  Osaka University Graduate School of Medicine, Associate Professor, 医学系研究科, 助教授 (00233776)
SATO Yoshinobu  Osaka University Graduate School of Medicine, Associate Professor, 医学系研究科, 助教授 (70243219)
HAMA Hiromitsu  Osaka City University, Professor, 工学部, 教授 (20047377)
内藤 博昭  大阪大学, 医学系研究科, 教授 (60217627)
Project Period (FY) 2000 – 2003
Project Status Completed (Fiscal Year 2003)
Budget Amount *help
¥11,900,000 (Direct Cost: ¥11,900,000)
Fiscal Year 2003: ¥1,100,000 (Direct Cost: ¥1,100,000)
Fiscal Year 2002: ¥1,400,000 (Direct Cost: ¥1,400,000)
Fiscal Year 2001: ¥2,200,000 (Direct Cost: ¥2,200,000)
Fiscal Year 2000: ¥7,200,000 (Direct Cost: ¥7,200,000)
KeywordsIntra-body localization / Ultrasound / Endoscope / 3D position sensor / Transducer / トランスジューサ / 体内位置決め / 3次元位置センサー / 磁気センサー / 斜視鏡 / 磁気
Research Abstract

Different from conventional virtual navigation, we have developed two real intra-body navigation systems, which support endoscopic examination and endoscopic surgery.
(1)Ultrasound method
Commercially available ultrasound probe is set in water pool and another ultrasound transducer is placed at separated position which transmits ultrasound pulses synchronized to the ultrasound probe. The ultrasound probe catches the transmitted pulse from the transducer and displays on a monitor of the commercially available ultrasound diagnostic equipment as a marker. Thus we can locate the position (six dgrees-of-freedom) of the ultrasound probe as the relative position from the ultrasound transducer, and consequently as the absolute position by using optical localizer for ultrasound transducer.
(2)Hybrid method with magnetic and optical localizers
In this research, end of hard grip lod of an ultrasound endoscope is localized by an optical localizer and another end of the hard lod is localized bymagnetic sensor which is used for measuring magnetic field and location calibration/compensation. At another end of the hard lod, flexible ultrasound probe lod is connected. Another miniature magnetic sensor is attached at the tip of the flexible probe lod to locate the ultrasound probe in five degrees-of-freedom. Thus we can locate the ultrasound probe with six-degrees-of-freedom, whose locating precision is improved from 14.7mm without compensation to 1.96mm. Further we have derived the geometry of oblique endoscope and developed an easy calibration method.

Report

(5 results)
  • 2003 Annual Research Report   Final Research Report Summary
  • 2002 Annual Research Report
  • 2001 Annual Research Report
  • 2000 Annual Research Report
  • Research Products

    (27 results)

All Other

All Publications (27 results)

  • [Publications] 平野雅嗣: "内視鏡ナビゲーションのための体腔内超音波プローブ位置決め精度検証"Med.Imag.Tech. Vol.18,No.5. 735-739 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Shinichi Tamura: "Intra-body three-dimensional position sensor for an ultrasound endoscope"IEEE Trans on Biomedical Engineering. vol.49,No.10. 1187-1194 (2002)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 中田和久: "光磁気ハイブリッド方式による磁気式3次元位置センサの簡便迅速な磁気ひずみ補正法"信学論D-II. vol.J87-D-II. 302-312 (2004)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 山口鉄藏: "斜視内視鏡のカメラモデルとキャリブレーション法の開発"信学論D-II. vol.J87-D-II. 313-324 (2004)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Hirano, Masatsugu: "Evaluation of Accuracy of Localizing an Intravascular Ultrasound Probe for Endoscope Navigation"Med.Imag.Tech. Vol.18,No.5. 735-739 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Shinichi Tamura: "Intra-body three-dimensional position sensor for an ultrasound endoscope"IEEE Trans on Biomedical Engineering. vol.49,No.10. 1187-1197 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Kazuhisa Nakada: "A Rapid Method for Magnetic Tracker Calibration Using a Magneto-Optic Hybrid Tracker"The IEICE Transactions on Information and Systems, PT.2 (JAPANESE EDITION). Vol.J87-D-II No.1. 302-312 (2004)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Tetsuzo Yamaguchi: "Development of Camera Model and Calibration Procedure for Oblique-Viewing Endoscope"The IEICE Transactions on Information and Systems, PT.2 (JAPANESE EDITION). Vol.J87-D-II No.1. 313-324 (2004)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 平野雅嗣: "内視鏡ナビゲーションのための体腔内超音波プローブ位置決め精度検証"Med.Imag.Tech. vol.18, No.5. 735-739 (2000)

    • Related Report
      2003 Annual Research Report
  • [Publications] Shinichi Tamura: "Intra-body three-dimensional position sensor for an ultrasound endoscope"IEEE Trans on Biomedical Engineering. vol.49, No.10. 1187-1194 (2002)

    • Related Report
      2003 Annual Research Report
  • [Publications] 中田和久: "光磁気ハイブリッド方式による磁気式3次元位置センサの簡便迅速な磁気ひずみ補正法"信学論D-II. vol.J87-D-II. 302-312 (2004)

    • Related Report
      2003 Annual Research Report
  • [Publications] 山口鉄藏: "斜視内視鏡のカメラモデルとキャリブレーション法の開発"信学論D-II. vol.J87-D-II. 313-324 (2004)

    • Related Report
      2003 Annual Research Report
  • [Publications] Shinichi Tamura: "Intra-body three-dimensional position sensor for an ultrasound endoscope"IEEE Trans on Biomedical Engineering. vol.49, No.10. 1187-1194 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] Kozo Konishi: "Development of AR navigation system for Iaparoscopic surgery using magneto-optic hybrid sensor : experiences with 3 cases"Computer Assisted Radiology and Surgery, Proc. 16th International Congress and Exhibition (Springer, Berlin). 1092 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] Masahiko Nakamoto: "3D Ultrasound System Using a Magneto-optic Hybrid Tracker for Augmented Reality Visualization in Laparoscopic Liver surgery"Lecture Notes in Computer Science 2489 (Proc.5th International Conference on MICCAI2002). Pt.II. 148-155 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 宮本仁樹: "3次元超音波システムのシミュレーションによる誤差解析"電子情報通信学会技術報告書. Vol.101, No.580. 19-24 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 中田和久: "光磁気ハイブリッド3次元位置センサを用いた磁場歪みの実時間補正"電子情報通信学会技術報告書. Vol.102, No.300. 33-38 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 中本将彦: "光磁気ハイブリッド3次元位置センサの性能評価"電子情報通信学会技術報告書. Vol.102, No.300. 39-44 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 山口鉄藏: "斜視内視鏡のキャリブレーション"電子情報通信学会技術報告書. Vol.102, No.300. 45-48 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 中田和久: "光磁気ハイブリッド三次元位置センサによる実時間磁場補正機能付き腹腔鏡対応三次元超音波システムの開発"第11回日本コンピュータ外科学会大会02(X)-55 Medical Imaging Technology. 20巻4号. 109-110 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 中本将彦: "斜視鏡に対応した腹腔鏡下手術ナビゲーションシステムの開発"第11回日本コンピュータ外科学会大会02(X)-55 Medical Imaging Technology. 20巻4号. 113-114 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 山口鉄藏: "斜視内視鏡投影モデルとキャリプレーション手法の評価"電子情報通信学会技術報告書. Vol.102, No.577. 11-16 (2003)

    • Related Report
      2002 Annual Research Report
  • [Publications] 中田和久: "光磁気ハイブリッド三次元位置センサによる実時間磁場補正機能付き腹腔鏡対応三次元超音波システムの開発-近似次数の選択尺度の検討並びに計測遅延補正による精度改善-"電子情報通信学会技術報告書. Vol.102, No.577. 17-22 (2003)

    • Related Report
      2002 Annual Research Report
  • [Publications] 宮本仁樹, 中本将彦, 横木太, 中島義和, 佐藤嘉仲, 田村進一: "3次元超音波システムのシミュレーションによる誤差解析"電子情報通信学会技術報告Vol.101, No.580. MI2001-61. 19-24 (2002)

    • Related Report
      2001 Annual Research Report
  • [Publications] 中本将彦, 宮本仁樹, 中島義和, 佐藤嘉伸, 小西晃造, 橋爪誠, 田村進一: "光磁気ハイブリツドセンサを用いた拡張現実感システムの精度検証-3次元超音波画像を用いた腹腔鏡下手術支援に際して-"第10回日本コンピュータ外科学会大会誌. 01(IV)-20. 45-46 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] 宮本仁樹, 中島義和, 中本将彦, 佐藤嘉伸, 橋爪誠, 田村進一: "腹腔鏡下手術支援を目的とした光磁気ハイブリッドセンサによる3次元超音波画像の獲得"電子情報通信学会技術報告PRMU2001-3. MI2001-15(2001-05). 17-22 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] 平野雅嗣,楊博,佐藤嘉伸,田村進一,鳴海善文,前田宗宏,中村仁信: "内視鏡ナビゲーションのための体腔内超音波プローブ位置決め精度検証"Med.Imag.Tech.. Vol.18,No.5. 735-739 (2000)

    • Related Report
      2000 Annual Research Report

URL: 

Published: 2000-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi