Development of quality control system of computed tomographic X-ray unit to decrease patient dose in diagnosis

Research Project

Project/Area Number 12557223
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section展開研究
Research Field Medical sociology
Research InstitutionOsaka University

Principal Investigator

MATSUMOTO Masao  Osaka Univ., Medicine, Associate Prof., 医学部, 助教授 (50149944)

Co-Investigator(Kenkyū-buntansha) KANAMORI Hitoshi  Fukui Institute of Technology, Engineering, Prof., 工学部, 教授 (70027770)
OGATA Yuji  Osaka Univ., Medicine, Assistant, 医学部, 助手 (60281127)
KUBOTA Hideaki  Osaka Univ., Medicine, Assistant, 医学部, 助手 (30234496)
ATSUMI Michifumi  Tokyo Medic. Co. Ltd., R & D Section, Researcher, 機器開発課, 研究職
Project Period (FY) 2000 – 2001
Project Status Completed (Fiscal Year 2001)
Budget Amount *help
¥6,400,000 (Direct Cost: ¥6,400,000)
Fiscal Year 2001: ¥1,300,000 (Direct Cost: ¥1,300,000)
Fiscal Year 2000: ¥5,100,000 (Direct Cost: ¥5,100,000)
KeywordsX-ray CT system / Primary x-ray spectrum / 90°-scattered X-ray spectrum / CdZnTe detector / Monte Carlo simulation / CdZnTe検出器
Research Abstract

We have attempted to calculate a primary X-ray -spectrum of CT (Computed Tomography) system. Dose rates of primary X-ray spectrum are very high, so we reduced dose rate by using carbon scatterer and enabled to measure 90℃ scattered spectrum with a CdZnTe detector. The primary X-ray spectrum can be calculated from measured data of 90℃ scattered spectrum by counting backwards. In counting backwards, we used not only Klein-Nishina coefficients but also response functions obtained by Monte Carlo methods, because Raylei scattering and multiple scattering maybe occur in carbon scatterer.
In our results, the primary X-ray spectrum calculated from response functions obtained by Monte Carlo methods are roughly equivalent to that calculated from Klein-Nishina coefficients.

Report

(3 results)
  • 2001 Annual Research Report   Final Research Report Summary
  • 2000 Annual Research Report
  • Research Products

    (33 results)

All Other

All Publications (33 results)

  • [Publications] 松本政雄, 稲邑清也: "フラットパネルディテクタの物理特性について"医学物理. 20suppl.7. 17-42 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] M.Matsumoto, S.Miyajima, A.Yamamoto, T.Yamazaki, H.Kanamori: "Measurement of diagnodtic X-ray spectra using CdZuTe detector"Abstract of 10th International Congress of The International Radiation protection Association. 306 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] 山崎隆治, 隅田伊織, 松本政雄, 他6名: "CT装置の一次X線スペクトルの解析"医用画像情報学会雑誌. 17(2). 88-96 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] M.Matsumoto, A.Yamamoto, I.Honda, A.Taniguchi, H.Kanamori: "Direct measurement of mammographic X-ray Spectra using a CdZnTe dotector"Medical Physics. 27(7). 1490-1502 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] 松本政雄, 久森克利, 他5名: "間接型フラットパネルディテクタの物理特性の測定"日本写真学会誌. 63(4). 210-216 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] 山本明秀, 松本政雄, 他4名: "CdZnTe半導体検出器で測定した乳房撮影用X線装置の被写体コントラストの解析"医用画像情報学会雑誌. 17(3). 130-137 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] S.Miyajima, H.Sakuragi, M.Matsumoto: "CdZnTe detector as an X-ray spectrometer"Physics of Medical Inaging, SPIE. 4320. 148-155 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] Y.Asai, H.Kanamori, Y.Ozaki, A.Takigawa, H.Kubota, M.Matsumoto: "Reduction of patient dose medical radiographs using scottered X-rays"Medical Imaging Acquisition and Processing, SPIE. 4549. 86-91 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] 松本政雄, 稲邑清也: "平面検出器"映像情報メディア学会誌. 55(5). 603-607 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] Matsumoto Masao, Yamazaki Takahara, Ogata Yuji, Kubota Hideaki et al.: "Measurement of computed tomography X-ray Spectra using a CdZuTe detector"Radiation Detectors and Their Uses, KEK Proc.. 2001-20. 88-96 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] S.Miyajima, K.Imagawa, M.Matsumoto: "The CdZnTe detector in the measurement of mammographic X-ray spectra"Radiation Detectors and Their Uses, KEK Proc.. 2001-20. 97-105 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] 松本政雄, 稲邑清也: "フラットパネル-物理特性"Radioligy Frontier. 4(4). 33-37 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] M. Matsumoto, S. Miyajima, A. Yamamoto, T. Yamazaki and H. Kanamori: "Measurement of diagnostic x-ray spectra using CdZnTe detector"Abstract of 10th International Congress of The International Radiation Protection Association. 306-306 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] H. Arimura, T. Date, K. Morikawa, H. Kubota, M. Matsumoto and H. Kanamori: "Evaluation of patient skin doses and signal-to-noise ratios of radiographic images in x-ray imaging system"Abstract of 10th International Congress of The International Radiation Protection Association. 304-304 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] H. Kanamori, Y. Asai, Y. Ozaki, H. Kubota and M. Matsumoto: "Evaluation of image noise asymmetric x-ray screen/film systems using a single frequency value of psychophysical Wiener spectrum"Abstract of 10th International Congress of The International Radiation Protection Association. 306-307 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] H. Kanamori, Y. Asai, Y. Ozaki, H. Kubota and M. Matsumoto: "Optimum tube voltage for chest radiographs obtained by psychophysical analysis"Proceedings of the second Beijing International Congress of Medical Radiation Physics. 99-100 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] M. Matsumoto, A. Yamamoto, I. Honda, A. Taniguchi, H. Kanamori: "Direct measurement of mammograpic x-ray spectra using a CdZnTe detector"Medical Physics. 27 (7). 1190-1502 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] S. Miyajima, A. Yamamoto, T. Yamazaki, H. Kubota, M. Matsumoto, H. Kanamori: "Some diagnostic x-ray spectra and exposure measured using CdZnTe detector"Abstract of 10th International Congress in Medical Physics and Biomedical Engineering, Medical Physics. 27 (6). 1428-1428 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] S. Miyajima, H. Sakurai, M. Matsumoto: "CdZnTe detector as an x-ray spectrometer"Physics of Medical Imaging, SPIE. 4320. 148-155 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] Y. Asai, H. Kanamori, Y. Ozaki, A. Takizawa, H. Kubota and M. Matsumoto: "Reduction of patient dose on medical radiographs using scattered x-rays"Medical Image Acquisition and Proceeding, SPIE. 4549. 86-91 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] Matsumoto Masao, Yamazaki Takaharu, Ogara, Yuji, Kubota Hideaki, Nakashima Yoshito, Kanamori, Hitoshi and Onabe Hideaki: "Measurement of computed tomography x-ray spectra using a CdZnTe detector"Radiagion Detectors and Theire User, 2001, KEK PRoc.. 2001-20. 88-96 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] S. Miyajima, K. Imagawa and M. Matsumoto: "The CdZnTe detector in the measurement of mammography x-ray spectra"Radiation Detectors and Theire User, 2001, KEK PRoc.. 2001-20. 97-105 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] S.Miyajima, H.Sakuragi, M.Matumoto: "CdZnTe detector as an X-ray spectrometer"Physics of Medical Imaging, SPIE. 4320. 148-155 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] Y.Asai, H.Kanamori, Y.Ozaki, A.Takigawa, H.Kubota, M.Matsumoto: "Reduction of patient dose on medical radiographs using scattered X-rays"Medical Image Acquisition and Processing, SPIE. 4549. 86-91 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] 松本政雄, 稲邑清也: "平面検出器"映像情報メディア学会誌. 55・5. 603-607 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] Matsumoto Masao, Yamazaki Takaharu, Ogata Yuji, Kubota Hideaki et al.: "Measurement of computed tomography x-ray spectra using a CdZnTe detector"Radiation Detectors and Their Uses 2001, KEK Proc.. 2001・20. 88-96 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] S.Miyajima, K.Imagawa, M.Matsumoto: "The CdZnTe detector in the measurement of mammographic x-ray spectra"Radiation Detectors and Their Uses 2001, KEK Proc.. 2001・20. 97-105 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] 松本政雄, 稲邑清也: "フラットパネル-物理特性"Radiology Frontier. 4・4. 33-37 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] 松本政雄,稲邑清也: "フラットパネルディテクタの物理特性について"医学物理. 20・Supp.No.1. 17-42 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 山崎隆治,隅田伊織,松本政雄 他6名: "CT装置の一次X線スペクトルの解析"医用画像情報学会雑誌. 17・2. 88-96 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] M.Matsumoto,A.Yamamoto et al.: "Direct measurement of mammographic X-ray spectra using a CdZnTe detector"Medical Physics. 27・7. 1490-1502 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 松本政雄 他6名: "間接型フラットパネルディテクタの物理特性の測定"日本写真学会誌. 63・4. 210-216 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 山本明秀,松本政雄 他4名: "乳房撮影用X線装置の被写体コントラストの解析"医用画像情報学会雑誌. 17・3. 130-137 (2000)

    • Related Report
      2000 Annual Research Report

URL: 

Published: 2000-04-01   Modified: 2016-04-21  