• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of wavelength-independent back-illuminated CCD detector and its application

Research Project

Project/Area Number 12558051
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section展開研究
Research Field Nuclear fusion studies
Research InstitutionNational Institute for Fusion Science

Principal Investigator

MORITA Shigeru  National Institute for Fusion Science, LHD project, associate professor, 大型ヘリカル研究部, 助教授 (80174423)

Co-Investigator(Kenkyū-buntansha) MUTO Sadatugu  National Institute for Fusion Science, LHD project, researcher, 大型ヘリカル研究部, 助手 (40260054)
GOTO Motoshi  National Institute for Fusion Science, LHD project, researcher, 大型ヘリカル研究部, 助手 (00290916)
Project Period (FY) 2000 – 2003
Project Status Completed (Fiscal Year 2003)
Budget Amount *help
¥10,800,000 (Direct Cost: ¥10,800,000)
Fiscal Year 2003: ¥2,300,000 (Direct Cost: ¥2,300,000)
Fiscal Year 2002: ¥2,200,000 (Direct Cost: ¥2,200,000)
Fiscal Year 2001: ¥2,200,000 (Direct Cost: ¥2,200,000)
Fiscal Year 2000: ¥4,100,000 (Direct Cost: ¥4,100,000)
KeywordsCCD detector / Visible spectroscopy / VUV spectroscopy / X-ray spectroscopy / Plasma diagnostics / Spectrometer / プラズマ分光
Research Abstract

During past 4 years we experimentally verified many advantages on back-illuminated CCD detector, which was used in visible, vacuum ultraviolet (VUV) and x-ray plasma spectroscopy. The CCD detector was being operated without any technical trouble through this research. As a most important result it was concluded that no limit on the measurement existed for such variations of spectroscopy. Excellent characteristics of the CCD detector on the stability of sensitivity and the spatial-and time-resolution, which were examined in this research, can be applicable to another field of scientific research.
In the visible region, the characteristics of the back-illuminated CCD were compared with photodiode array (PDA) with image intensifier (II) used for the visible spectroscopy. The characteristics of the CCD was much superior to the PDA+II in many terms of sudden detector destruction due to strong visible light input, sensitivity change over long period, spectral profile shape at foot position, s … More patial resolution, dynamic range for signal detection, time resolution, operational stability, S/N ratio etc.
In the VUV region, the characteristics of the back-illuminated CCD were compared with PDA with micro-channel plate (MCP). The detectors were installed on a 20cm normal incidence spectrometer and checked using CHS and LHD plasma light. The result was the same as the visible case. The CCD detector had much better quality. Especially, the CCD did not show, any damage to increase of the vacuum pressure of the spectrometer, although the operation of M C P was very sensitive to the pressure increase and the CCD was easily damaged by the pressure increase. In addition, the use of CCD as a detector of VUV spectrometer enabled us a very easy setting and adjustment of the grating because we could exactly monitor the focus image at the detector plane using 0th-order (visible) light.
In the x-ray region, the characteristics of the CCD detector were compared with usually used multiwire proportional counter (MWPC ). In x-ray emissions. from plasmas the intensity is a large function of electron temperature. Then, the x-ray intensity largely changes during a discharge and is easily enhanced by an additional heating. As a result, the x-ray spectroscopy was limited by the detector signal dynamic range. The use of the CCD detector instead of the MWPC increased the detector dynamic range by 1000 times. Until now the ion temperature measurement by the x-ray spectroscopy included a considerably large error bar. However, we could completely resolve the problem using the CCD detector. Less

Report

(5 results)
  • 2003 Annual Research Report   Final Research Report Summary
  • 2002 Annual Research Report
  • 2001 Annual Research Report
  • 2000 Annual Research Report
  • Research Products

    (32 results)

All Other

All Publications (32 results)

  • [Publications] S.Morita, M.Goto: "Space resolved VUV spectroscopy using the 3m normal incidence spectrometer with back-illuminated CCD detector in the LHD"Review of Scientific Instruments. Vol.74. 2036-2039 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] S.Morita, M.Goto: "X-ray crystal spectrometer with a charge-coupled-device detector for ion temperature measurements in the Large Helical Device"Review of Scientific Instruments. Vol.74. 2375-2387 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] S.Morita, M.Goto et al.: "Experimental study on ion temperature behaviours in ECH, ICRF and NBI H2, He and Ne discharges of the Large Helical Device"Nuclear Fusion. Vol.43. 899-909 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] S.Morita et al.: "H-mode-like discharge under the presence of 1/1 rational surface arergodic layer in LHD"Journal of Plasma Fusion Research. Vol.80. 279-280 (2004)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] M.Goto, S.Morita et al.: "Determination of the hydrogen and helium ion densities in the initial and final stages of a plasma in the LHD by optical spectroscopy"Physics of Plasmas. Vol.10. 1402-1410 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] S.Muto, S.Morita et al.: "First measurement of hard x-ray spectrum emitted from high-energy electrons in electron cyclotron heated plasma of LHD"Review of Scientific Instruments. Vol.74. 1993-1996 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] S.Morita, M.Goto et al.: "Space-resolved VLTV spectroscopy using the 3m normal incidence spectrometer with back-illuminated CCD detector in the LHD"Review of Scientific Instruments. Vol.74. 2036-2039 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] S.Morita, M.Goto et al.: "X-ray crystal spectrometer with a charge-coupled-device detector for ion temperature measurements in the Large Helical Device"Review of Scientific Instruments. Vol.74. 2375-2387 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] S.Morita, M.Goto et al.: "Experimental study on ion temperature behaviors in ECH, ICRF and NBI H2, He and Ne discharges of the Large Helical Device"Nuclear Fusion. Vol.43. 899-909 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] S.Morita et al.: "H-mode-like discharge under the presence of 1/1 rational surfacear ergodic layer in LHD"Journal of Plasma Fusion Research. Vol.80. 279-280 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] M.Goto, S.Morita et al.: "Determination of the hydrogen and helium ion densities in the initial and final stages of a plasma in the LHD by optical spectroscopy"Physics of Plasmas. vol.10. 1402-1410 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] S.Muto, S.Morita et al.: "First measurement of hard x-ray spectrum emitted from high-energy electrons in electron cyclotron heated plasma of LHD"Review of Scientific Instruments. vol.74. 1993-1996 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] S.Morita, M.Goto: "Space-resolved VUV spectroscopy using the 3m normal incidence spectrometer with back-illuminated CCD detector in the LHD"Review of Scientific Instruments. Vol.74. 2036-2039 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] S.Morita, M.Goto: "X-ray crystal spectrometer with a charge-coupled-device detector for ion temperature measurements in the Large Helical Device"Review of Scientific Instruments. Vol.74. 2375-2387 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] S.Morita, M.Goto, et al.: "Experimental study on ion temperature behaviours in ECH,ICRF and NBI H2,He and Ne discharges of the Large Helical Device"Nuclear Fusion. Vol.43. 899-909 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] S.Morita, et al.: "H-mode-like discharge under the presence of 1/1 rational surface at ergodic layer in LHD"Journal of Plasma Fusion Research (Rapid Communication). Vol.80(To be published). (2004)

    • Related Report
      2003 Annual Research Report
  • [Publications] M.Goto, S.Morita, et al.: "Determination of the hydrogen and helium ion densities in the initial and final stages of a plasma in the LHD by optical spectroscopy"Physics of Plasmas. Vol.10. 1402-1410 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] S.Muto, S.Morita, et al.: "First measurement of hard x-ray spectrum emitted from high-energy electrons in electron cyclotron heated plasma of LHD"Review of Scientific Instruments. Vol.74. 1993-1996 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] S.Morita et al.: "Observation of ablation and acceleration of impurity pellets in the presence of energetic ions in the CHS heliotron/torsatron"Nuclear Fusion. Vol.42. 876-880 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] S.Morita et al.: "Behavior of ion temperature in electron and Ion heating regimes observed with ECH, NBI and ICRF discharges of LHD"Nuclear Fusion. Vol.42. 1179-1183 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] S.Morita, M.Goto: "Space-resolved VUV spectroscopy using the 3m normal incidence spectrometer with back-illuminated CCD detector in the LHD"Review of Scientific Instruments. Vol.74. 2036-2039 (2003)

    • Related Report
      2002 Annual Research Report
  • [Publications] S.Morita, M.Goto: "X-ray crystal spectrometer with a charge-coupled-device detector for ion temperature measurements in the Large Helical Device"To be published in Review of Scientific Instruments. Vol.74. (2003)

    • Related Report
      2002 Annual Research Report
  • [Publications] M.Goto, S.Morita: "Hydrogen and helium spectroscopy of initial and final stages of a plasma in the Large Helical Device Determination of the ion densities"To be published in Plasma Physics. (2003)

    • Related Report
      2002 Annual Research Report
  • [Publications] S.Muto, S.Morita et al.: "First measurement of hard x-ray spectrum emitted from high-energy electrons in electron cyclotron heated plasma of LHD"Review of Scientific Instruments. Vol.74. 1993-1996 (2003)

    • Related Report
      2002 Annual Research Report
  • [Publications] Shigeru MORITA: "Effect of carbon divertor Plates on impurities, Zeff and density limit in large helical device"Physica Scripta. T91. 48-52 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] Shigeru MORITA: "Observation of ablation and acceleration of impurity pellets under existence of energetic ions in CHS heliotron/torsatron"To be published in Nuclear Fusion. 42. (2002)

    • Related Report
      2001 Annual Research Report
  • [Publications] Motoshi GOTO: "Determination of the line emission locations in a large helical device on the basis of the Zeeman effect"Physical Review E. 65. 026401 (2002)

    • Related Report
      2001 Annual Research Report
  • [Publications] Sadatsugu MUTO: "First from x-ray pulse height analyzer with radial scanning system for LHD"Peview of Scientific Instruments. 72. 1206-1209 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] Shigeru Morita: "Effect of carbon divertor plates on impurities, Zeff and density limit in large helical device"Physica Scripta. (to be published).

    • Related Report
      2000 Annual Research Report
  • [Publications] 森田繁: "背面照射型CCD検出器を利用した可視,真空紫外,X線分光計測"プラズマ核融合学会誌. 76. 1237-1243 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] Motoshi Goto: "Balmer-α intensity and particle flux in plasma edge region of LHD"Physica Scripta. (to be published).

    • Related Report
      2000 Annual Research Report
  • [Publications] Sadatsugu Muto: "First result from x-ray pulse height analyzer with radial scanning system for LHD"Review of Scientific Instruments. 72. 1206-1209 (2001)

    • Related Report
      2000 Annual Research Report

URL: 

Published: 2000-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi