Development of ultra-wide range biotelemetry and telemonitoring system

Research Project

Project/Area Number 12558098
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section展開研究
Research Field Biomedical engineering/Biological material science
Research InstitutionHOKKAIDO UNIVERSITY

Principal Investigator

SHIMIZU Koichi  Hokkaido Univ., Grad. Sch. of Eng., Professor, 大学院・工学研究科, 教授 (30125322)

Co-Investigator(Kenkyū-buntansha) YASUDA Kazunori  Hokkaido Univ., Grad. Sch. of Med., Professor, 大学院・工学研究科, 教授 (20166507)
KATO Yuji  Hokkaido Univ., Grad. Sch. of Eng., Inst., 大学院・工学研究科, 助手 (50261582)
SHIMOOKA Toshiyuki  Hokkaido Univ., Grad. Sch. of Eng., Assoc. Prof., 大学院・工学研究科, 助教授 (50196549)
MATSUDA Seiji  Kokusai Electric Co., Ltd., Telecom Sys. Div., Leader, 通信システム事業部, 主任(研究職)
YAMASHITA Masaji  Hokkaido Inst. Tech., Fac. of Eng., Assoc.Prof., 工学部, 助教授 (40210421)
Project Period (FY) 2000 – 2001
Project Status Completed (Fiscal Year 2001)
Budget Amount *help
¥4,400,000 (Direct Cost: ¥4,400,000)
Fiscal Year 2001: ¥1,400,000 (Direct Cost: ¥1,400,000)
Fiscal Year 2000: ¥3,000,000 (Direct Cost: ¥3,000,000)
Keywordsbiological information / vital-sign / mobile communication / telemetry / monitoring / PHS / data transmission / mobile equipments
Research Abstract

A telemetry technique and a test-system have been developed to realize continuous vital-sign monitoring for the senior citizens living alone and the patient in home care. The following research has been conducted.
1. A ring-type sensor was designed to measure pulse-wave optically without interfering a daily activity of the subject. The telemeter using the ring-type sensor satisfied the practical demands for signal fidelity, transmission range, size, weight and battery life.
2. A technique of two-step telemetry was newly devised to meet the antagonizing requirements for low constraint and wide coverage-area at the same time.
3. Using a PHS terminal, an ultra-wide area telemonitoring system has been developed to realize the above technique.
4. Using the developed system, the practicality and the usefulness of the proposed technique was tested in normal and unfavorable environmental conditions.
Through this study, the following results were obtained. A vital-sign can be continuously monitored almost unconsciously. Usually the range of telemonitoring had been confined in a home. With this technique, the range has been expanded to the extent of almost all the domestic areas. A practical technique has been developed to monitor a vital-sign using a wearable common terminal both inside and outside the home. In the home, the cellular phone terminal serves as a cordless phone and no network charge is required. Through the experiments, the feasibility of the proposed technique and the practical usefulness of the developed system were verified.

Report

(3 results)
  • 2001 Annual Research Report   Final Research Report Summary
  • 2000 Annual Research Report
  • Research Products

    (26 results)

All Other

All Publications (26 results)

  • [Publications] K.Simizu, et al.: "Development of vital-sign telemonitoring system using mobile phone communication"Biotelemetry. 16(in press). (2002)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] M.Yamashita, et al.: "Development of biotelemetry technique for EEG/ECG measurement in a strong ELF electric field"Transactions of IEEJ. (in press). (2002)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] K.Simizu, et al.: "Practical considerations for location system of moving person"Biotelemetry. 15. 639-645 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] 戸谷伸之, 他: "間接散乱光を用いたスペクトル拡散多重化伝達の基礎特性解析-光バイオテレメトリの多重化をめざして-"電子情報通信学会論文誌. J83-B. 780-788 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] 山下政司, 他: "指輪型バイタルサインモニタの試作"電気学会論文誌. 120-C. 1130-1134 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] K.Simizu, et al.: "Development of indoor-outdoor common biotelemetry technique"Biotelemetry. 15. 563-568 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] 清水孝一(分担執筆): "生体計測の機器とシステム(岡田正彦編)"コロナ社. 10/219 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] Koichi Shimizu, Takanori Suzuki, Takahiro Nishida: "Development of vital-sign telemonitoring system using mobile phone communication"Biotelemetry. vol. 16, (in press).

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] Masaji Yamashita, Kazuo Ohsaki, Koichi Shimizu: "Development of bio-telemetry technique for EEG/ECG measurement in a strong ELF electric field"Transactions of IEEJ. (in press).

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] Koichi Shimizu, Kuniaki Kawamura, Katsuyuki Yamamoto: "Practical considerations for location system of moving person"Biotelemetry. vol. 15. 639-645 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] Nobuyuki Toya, Koichi Shimizu: "Fundamental analysis of multichannel spread spectrum data transmission using indirect scattered light - To realize multichannel optical biotelemetry -"Transactions of IEICE. vol. J83-B. 780-788 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] Koichi Shimizu: "Development of prototype for a ring-type vital sign monitor"Trans. of IEEJ. vol. 120-C. 1130-1134 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] Koichi Shimizu, Takanori Suzuki: "Development of indoor-outdoor common biotelemetry technique"Biotelemetry. 15. 563-568 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] Koichi Shimizu (cowriter): ""Measuring Systems for Biological Signals" (ed. M. Okada)"Corona Publishing Co., Ltd.. (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2001 Final Research Report Summary
  • [Publications] K.Shimizu, et al.: "Development of vital-sign telemonitoring system using mobile phone communication"Biotelemetry. 16(in press). (2002)

    • Related Report
      2001 Annual Research Report
  • [Publications] M. Yamashita, et al.: "Development of biotelemetry technique for the measurement in strong ELF electric field"Biotelemetry. 16(in press). (2002)

    • Related Report
      2001 Annual Research Report
  • [Publications] N. Toya, et al.: "Performance analysis of spread spectrum data transmission for biotelemetry using IR light"Biotelemetry. 16(in press). (2002)

    • Related Report
      2001 Annual Research Report
  • [Publications] M. Yamashita, et al.: "Development of biotelemetry technique for EEG/ECG measurement in strong ELF electric field"Transactions of IEEJ. (in press). (2002)

    • Related Report
      2001 Annual Research Report
  • [Publications] K. Shimizu, et al.: "Ultra-wide range vital sign monitoring using mobile communication"Conf. Dig. of AP-RASC'01. 265 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] K. Shimizu, et al.: "Development of wide-area biotelemetry system using mobile phone network"Proc. of 63rd ICB Seminar. 44-45 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] T.Nishida, et al.: "Development of vital-sign telemonitoring system using mobile phone communication"Biotelemetry. 16(in press). (2001)

    • Related Report
      2000 Annual Research Report
  • [Publications] N.Toya, et al.: "Performance analysis of spread spectrum data transmission for biotelemetry using indirect IR light"Biotelemetry. 16(in press). (2001)

    • Related Report
      2000 Annual Research Report
  • [Publications] K.Shimizu, et al.: "Ultra-wide range vital sign monitoring using mobile communication"Proceedings of AP-RASC. (in press). (2001)

    • Related Report
      2000 Annual Research Report
  • [Publications] 山下政司,他: "指輪型バイタルサインモニタの試作"電気学会論文誌. 120-C. 1130-1134 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 戸谷伸之,他: "間接散乱光を用いたスペクトル拡散多重化伝送の基礎特性解析-光バイオテレメトリの多重化を目指して-"電子情報通信学会論文誌. J83-B. 780-788 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] K.Shimizu, et al.: "Development of indoor-outdoor common biotelemetry technique"Biotelemetry. 15. (2000)

    • Related Report
      2000 Annual Research Report

URL: 

Published: 2000-04-01   Modified: 2016-04-21  