• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Nationwide Investigation of Relationship among Performance of Ventilation System, Ventilation rate and Indoor Air Quality in Airtight Houses

Research Project

Project/Area Number 13450232
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field Architectural environment/equipment
Research InstitutionTohoku University

Principal Investigator

YOSHINO Hiroshi  Tohoku University, Graduate School of Engineering, Professor, 大学院・工学研究科, 教授 (30092373)

Co-Investigator(Kenkyū-buntansha) SASAKI Takashi  Iwate Prefectural University, Morioka Junior College, Professor, 盛岡短期大学部, 教授 (30301849)
IKEDA Kouichi  The National Institute of Public Health, Department of Architectural Hygiene and Housing, Professor, 建築衛生学部, 部長 (90100057)
MOCHIDA Akashi  Tohoku University, Graduate School of Engineering, Associate Professor, 大学院・工学研究科, 助教授 (00183658)
NOZAKI Atsuo  Tohoku Bunka gakuen University, Faculty of Science and Technology, Associate Professor, 科学技術学部, 助教授 (80316447)
Project Period (FY) 2001 – 2003
Project Status Completed (Fiscal Year 2003)
Budget Amount *help
¥14,800,000 (Direct Cost: ¥14,800,000)
Fiscal Year 2003: ¥3,200,000 (Direct Cost: ¥3,200,000)
Fiscal Year 2002: ¥5,700,000 (Direct Cost: ¥5,700,000)
Fiscal Year 2001: ¥5,900,000 (Direct Cost: ¥5,900,000)
KeywordsPFT method / Verification of accuracy / Field Measurement / Questionnaire Survey / Ventilation System / Ventilation Rate / Indoor Air Quality / Interrelationship
Research Abstract

1.A new measuring method for evaluating ventilation rate was developed.
2.Ventilation rates and indoor air quality in airtight houses in most parts of Japan were investigated by field measurements. Field measurements were carried out in summer and winter for three years.
・The result of measurement of airflow at outlet shows that 19 (68%) houses out of 28 indicate a low air change rate, which is lower than 0.5 h^<-1>.
・The result of ventilation airflow rate by constant concentration method shows that 9 (43%) houses out of 21 indicate a low air change rate, which is lower than 0.5h^<-1>.
・The formaldehyde concentrations in 39 (40%) rooms of 98 exceeded the criterion of the guideline from the Ministry of Health, Labor and Welfare of Japan.
・TVOC concentrations in 52 (53%) rooms of 99 exceeded the criterion of the advisable value from the Ministry of Health, Labor and Welfare of Japan.
・In the residence where the amount of ventilation rates was insufficient, chemistry substance concentrations exceeded the criterion of the guideline in many cases.
3.Numerical of thermal and ventilation performance on airtight houses sere carried out. The accuracy of numerical analysis was checked by comparing numerical simulations and results of field measurement.
4.Solutions to problems in those houses were suggested by numerical simulations.

Report

(4 results)
  • 2003 Annual Research Report   Final Research Report Summary
  • 2002 Annual Research Report
  • 2001 Annual Research Report
  • Research Products

    (23 results)

All Other

All Publications (23 results)

  • [Publications] 吉野博, 天野健太郎, 他: "シックハウスにおける居住環境の実態と健康に関する調査研究"日本建築学会環境系論文集. No.567. 57-64 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 鈴木憲高, 吉野博, 他: "機械換気システムを備えた住宅における換気性状の実態把握と改善案の検討"日本建築学会大会学術講演梗概集. 梗概集D-2. 793-794 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 天野健太郎, 吉野博, 他: "シックハウスにおける室内空気質と居住者の健康状況に関する調査研究 その7 3ヵ年の調査概要と化学物質濃度測定結果"日本建築学会大会学術講演梗概集. 梗概集D-2. 901-902 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] H.Yoshino, K.Amano, etc.: "LONG-TERMED FIELD SURVEY OF INDOOR AIR QUALITY AND HEALTH HAZARD IN SICK HOUSES IN JAPAN"7^<th> Asia Pacific Conference on the Built Environment. 6-1-6-7 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] T.Mitamura, H.Yoshino, etc.: "Investigation of indoor air quality and ventilation rate for sick houses in Japan"Healthy Buildings 2003. Volume 1. 217-223 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] H.Yoshino, K.Ikeda, etc.: "Study of ventilation performance and indoor air quality in eight sick houses"Healthy Buildings 2003. Volume 3. 42-47 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Hiroshi Yoshino, Kentaro Amano, Nozomi Iida, Mari Matsumoto, Kouichi Ikeda, Atsuo Nozaki, Kazuhiko Kakuta, Sachiko Hojo, Satoshi Ishikawa: "Field Survey on Residential Environment and Health Conditions in Sick Houses"SUMMARIES OF TECHNICAL PAPERS OF ENVIRONMENT ENGINEERING OF ARCHITECTURAL INSTITUTE OF JAPAN. No.567. 57-64 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Noritaka Suzuki, Hiroshi Yoshino, Teruaki Mitamura, Mayumi Adachi: "Study of Ventilation Performance in Residential Houses with Mechanical Ventilation System"SUMMARIES OF TECHNICAL PAPERS OF ANNUAL MEETING ARCHITECTURAL INSTITUTE OF JAPAN. D-2. 793-794 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Kentaro Amano, Hiroshi Yoshino, Mari Matsumoto, Noritaka Suzuki, Nozomi Iida, Kouichi Ikeda, Atsuo Nozaki, Kazuhiko Kakuta, Sachiko Hojo, Satoshi Ishikawa: "Field Survey on Indoor Air Quality and Residens' Health Conditions in Sick Houses Part7"SUMMARIES OF TECHNICAL PAPERS OF ANNUAL MEETING ARCHITECTURAL INSTITUTE OF JAPAN. D-2. 901-902 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Hiroshi Yoshino, Kentaro Amano, Mari Matsumoto, Kouichi Ikeda, Atsuo Nozaki, Kazuhiko Kakuta, Sachiko Hojo, Satoshi Isikawa: "LONG-TERMED FIELD SURVEY OF INDOOR AIR QUALITY AND HEALTH HAZARD IN SICK HOUSES IN JAPAN"7^<th> ASIA PACIFIC CONFERENCE ON THE RUILT ENVIRONMENT. 6-1-6-7 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Teruaki Mitamura, Hiroshi Yoshino, Haruki Osawa, Yasuo Kuwasawa: "Investigation of indoor air quality and ventilation rate for sick houses in Japan"HEALTHY BUILDING 2003. Volume 1. 217-223 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Hiroshi Yoshino, Kouichi Ikeda, Atsuo Nozaki, Kentaro Amano, Jun Wada, Nozomi Iida, Noritaka Suzuki, Mari Matsumoto: "Study of ventilation performance and indoor air quality in eight sick houses"HEALTHY BUILDING 2003. Volume 3. 42-47 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 吉野博, 天野健太郎, 他: "シックハウスにおける居住環境の実態と健康に関する調査研究"日本建築学会環境系論文集. No.567. 57-64 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] 鈴木憲高, 吉野博, 他: "機械換気システムを備えた住宅における換気性状の実態把握と改善案の検討"日本建築学会大会学術講演梗概集. 梗概集D-2. 793-794 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] 天野健太郎, 吉野博, 他: "シックハウスにおける室内空気質と居住者の健康状況に関する調査研究 その7 3ヵ年の調査概要と化学物質濃度測定結果"日本建築学会大会学術講演梗概集. 梗概集D-2. 901-902 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] H.Yoshino, K.Amano, etc: "LONG-TERMED FIELD SURVEY OF INDOOR AIR QUALITY AND HEALTH HAZARD IN SICK HOUSES IN JAPAN"7^<th> Asia Pacific Conference on the Built Environment. 6-1-6-7 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] T.Mitamura, H.Yoshino, etc: "Investigation of indoor air quality and ventilation rate for sick houses in Japan"Healthy Buildings 2003. Volume 1. 217-223 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] H.Yoshino, K.Ikeda, etc: "Study of ventilation performance and indoor air quality in eight sick houses"Healthy Buildings 2003. Volume 3. 42-47 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] 吉野博, 大澤元毅, 他: "シックハウスに関連した室内空気環境の総合的調査 その1調査の概要"日本建築学会大会学術講演梗概集. 梗概集D-2. 925-926 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 三田村輝章, 吉野博, 他: "シックハウスに関連した室内空気環境の総合的調査 その2宮城県内の住宅4件における調査結果"日本建築学会大会学術講演梗概集. 梗概集D-2. 927-928 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 吉野博, 大澤元毅, 他: "シックハウスに関連した室内空気質と換気量の調査研究(その1)調査の概要と宮城県内の住宅12件における換気量の測定結果"空気調和・衛生工学会学術講演会講演論文集. I. 133-136 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 三田村輝章, 吉野博, 他: "シックハウスに関連した室内空気質と換気量の調査研究(その2)宮城県内の住宅12件における室内空気質の測定結果"空気調和・衛生工学会学術講演会講演論文集. I. 137-140 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 鈴木憲高, 吉野博, 他: "シックハウスに関連した室内空気質と換気量の調査研究(その3)3つの方法による換気量の測定結果に関する事例的分析"空気調和・衛生工学会学術講演会講演論文集. I. 141-144 (2002)

    • Related Report
      2002 Annual Research Report

URL: 

Published: 2001-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi