• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Low Temperature Fabrication of Diamond Films by CVD Method with Laser Induced Surface Reaction

Research Project

Project/Area Number 13450291
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field Material processing/treatments
Research InstitutionThe University of Tokyo

Principal Investigator

MITSUDA Yoshitaka  The University of Tokyo, Institute of Industrial Science, Professor, 生産技術研究所, 教授 (20212235)

Project Period (FY) 2001 – 2004
Project Status Completed (Fiscal Year 2004)
Budget Amount *help
¥15,100,000 (Direct Cost: ¥15,100,000)
Fiscal Year 2004: ¥2,200,000 (Direct Cost: ¥2,200,000)
Fiscal Year 2003: ¥2,800,000 (Direct Cost: ¥2,800,000)
Fiscal Year 2002: ¥2,200,000 (Direct Cost: ¥2,200,000)
Fiscal Year 2001: ¥7,900,000 (Direct Cost: ¥7,900,000)
Keywordsdiamond films / vapor growth / hydrogen atom / laser induced surface reaction / Nd : YAG laser / surface adsorption / laser induced desorption / low temperature fabrication / Nd : YAGレーザー
Research Abstract

The novel apparatus was designed and manufactured for thermal desorption and laser induced desorption. This apparatus has 4 kinds of inlet window through which laser beam can irradiate onto the sample (incident angle : 0-60o), XYZθ sample stage (detection angle : 0-80o), time-of-flight and/or quadrupole mass spectrometer, and sample heating system up to 1400oC. The dosing system, by which the sample surface can be modified, is the thermal cracking system through hot W tube which was replaced as a part of gas introduction tube, since the gas molecule can be dissociated on the inner wall of hot W tube. Therefore, we can choose either method to control the sample surface termination, using the thermal dissociation of molecules on hot sample surface or atomic flux generated in thermal cracking system.
Using this apparatus both for thermal desorption and for laser induced desorption, the dangling bonds on the sample surface was terminated by the thermal dissociation of deuterium on 1300K sam … More ple. Then, the thermal desorption spectrum of deuterium molecules was detected from the D-terminated surface. The termination structure of sample surface after dosing was confirmed by the result of thermal desorption spectra.
On basis of the results and speculation of thermal desorption measurement, laser induced desorption spectrum was detected using Nd : YAG pulse laser (fundamental - 4th harmonic wave). H2 desorption of H-terminated, CO and CO2 from O-terminated diamond crystal tried to be measured. After the sample was heated up to 200℃ to desorb physiabsorbed H2O and/or CO, a variety of lased wavelength and energy density of laser pulses were irradiated onto the sample. In case of the fundamental, 2nd, and 3rd harmonic wave, we could not detect any desorption spectra. Although we could detect desorption spectra in case of the 4th harmonic wave, it was not due to the desorption by the laser induced reaction at the surface bond, but due to the thermal desorption by the sample heating as a result of the absorption of laser pulse at the defects in diamond crystals. Less