• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Three dimensional image construction of heavy ion CT with use of residual range measurement

Research Project

Project/Area Number 13470188
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionIbaraki Prefectural University of Health Science

Principal Investigator

NISHIMURA Katsuyuki  IPU, Radiological Sciences, Professor, 保健医療学部, 教授 (10129158)

Co-Investigator(Kenkyū-buntansha) SATOH Hitoshi  IPU, Radiological Sciences, Research Associate, 助手 (90285057)
ABE Shinji  IPU, Radiological Sciences, Associate Professor, 助教授 (00274978)
INADA Tetsuo  IPU, Radiological Sciences, Professor, 教授 (50114038)
FUJISAKI Tatsuya  IPU, Radiological Sciences, Research Associate, 助手 (00285058)
Project Period (FY) 2001 – 2003
Project Status Completed (Fiscal Year 2003)
Budget Amount *help
¥13,900,000 (Direct Cost: ¥13,900,000)
Fiscal Year 2003: ¥600,000 (Direct Cost: ¥600,000)
Fiscal Year 2002: ¥5,800,000 (Direct Cost: ¥5,800,000)
Fiscal Year 2001: ¥7,500,000 (Direct Cost: ¥7,500,000)
Keywordsheavy ion CT / range / relative electron density / 3D display wavelet theory / wavelet theory / spatial resolution / multiple coulomb scattering / ICCD camera / 均一補正 / ビーム強度補正 / 分光スペクトル / 多重散乱 / フィルタ逆投影法 / 逐次近似法 / ビデオ信号 / レンジシフタ / CCDカメラ
Research Abstract

The aim of this research is to seek high-speed acquisition and high quality image, by analyzing spatial resolution and contrast resolution and to verify the feasibility of three-dimensional display of heavy ion CT image. Heavy ion CT apparatus was developed. The apparatus consisted of ^<14>C ion beam with 400Mev/u, computer controllable range shifter, fluorescent screen, ICCD video camera. Higher speed acquisition was realized with use of high-speed range modulator and with the development of acquisition program. The contributions of Coulomb multiple scattering, blurring at both the fluorescent screen and CCD video camera system to spatial resolution were analyzed separately and compared with overall spatial resolution. Theoretical relation explains well the results. The electron density resolution was measured as 0.02 relative to water. This agrees with that calculated with use of noise propagation theory from the noises on the projection image. Noise was reduced by the image processing applying the wavelet theory without degrading the spatial resolution. As the projection data were acquired with two-dimensional detector, volume data were useable. Surface rendering images were constructed from the volume data.

Report

(4 results)
  • 2003 Annual Research Report   Final Research Report Summary
  • 2002 Annual Research Report
  • 2001 Annual Research Report
  • Research Products

    (25 results)

All Other

All Publications (25 results)

  • [Publications] Shinji Abe, Katsuyuki Nishimura, Hitoshi Satoh et al.: "Heavy Ion CT system based on measurement of residual range distribution"Jpn J Med Phys. 22. 1-9 (2002)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Shinji Abe, Katsuyuki Nishimura, Hitoshi Satoh et al.: "Application of an Imaging Plate to Measurement of Resolution for Heavy Ion Imaging"Jpn J Med Phys. 21[suppl.2]. 30-33 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 富田哲也, 西村克之, 阿部慎司 他: "飛程分布測定による重粒子線CTのサイノグラム作成"医学物理. 21[suppl.3]. 180-183 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 村石 浩, 西村克之, 小由千鶴他: "逐次近似法による重粒子線CTの画像再構成"医学物理. 21[suppl.3]. 176-179 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 村石浩, 西村克之, 阿部慎司他: "重粒子線CTの画像再構成-逐次近似法による多重散乱の補正-"医学物理. 21[suppl.2]. 164-167 (2002)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 富田哲也, 西村克之, 阿部慎司他: "重粒子線CTにおける撮像系の高速化"医学物理. 22[suppl.2]. 160-163 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Katsuyuki Nishimura, Shinji Abe, Hitoshi Satoh et al.: "Evaluation of Spatial Resolution in Heavy Ion CT System"Jpn J Med Phys. 23[suppl.2]. 162-165 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Shinji Abe, Katsuyuki Nishimura, Hitoshi Satoh, Hiroshi Muraishi, Tetsuo Inada, Tetsuya Tomida, Tatsuya Fujisaki, Yasuyuki Futami, Tatsuaki Kanai, Kiyomitsu Kawachi, Shuichi Tazawa: "Heavy Ion CT system based on measurement of residual rage distribution"Jpn J Med Phys.. 22. 1-9 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Tetsuo Inada, Tetsuya Tomida, Tatsuya Fujisaki, Hiroshi Muraishi, Yasuyuki Futami, Tatsuaki Kanai, Toshiaki Irie, Kiyomitsu Kawachi, Shuichi Tazawa, Mitsutaka Kakeno: "Application of a Imaging Plate to Measurement of Resolution for Heavy Ion Imaging"Jpn J Med Phys.. 21[Supple.2]. 30-33 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Tetsuya Tomida, Katsuyuki Nishimura, Shinji Abe, Hitoshi Satoh, Tetsuo Inada, Shuichi Tazawa, Tatsuaki Kanai, Kiyoimitsu Kawachi: "Sinogram for Heavy Ion CT by Measurement of Residual Range distribution (in Japanese)"Jpn J Med Phys.. 21[Supple.3]. 180-183 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Tetsuya Tomida, Katsuyuki Nishimura, Shinji Abe, Hitoshi Satoh, Hiroshi Muraishi, Akio Hashimoto, Tetsuo Inada, Shuichi Tazawa, Tatsuaki Kanai, Kiyomitsu Kawachi: "Improvement of Acquisition Speed in Heavy Ion CT System (in Japanese)"Jpn J Med Phys.. 22[Suppl.2]. 160-163 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Hiroshi Muraishi, Katsuyuki Nishimura, Sinji Abe, Hitoshi Satoh, Tetsuya Tomida, Tetsuo Inada, Tatuya Fujisaki, Shuichi Tazawa, Tatsuaki Kanai^<1)>, Kiyomitsu Kawachi: "Image Reconstruction in Heavy Ion CT -Correction of Multiple Scattering using Iterative Reconstruction Technique-"Jpn J Med Phys.. 22[Suppl.2]. 164-167 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Katsuyuki Nishimura, Shinji Abe, Hitoshi Satoh, Tetsuya Tomida, Naruomi Ysuda, Hiroshi Muraishi Ken Yusa, Tatsuaki Kanai, Tazawa S, Masahiro Endo, Inada T: "Evaluation of Spatial Resolution in Heavy Ion CT System"Jpn J Med Phys.. 23[Suppl.2]. 162-165 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Hiroshi Muraishi, Katsuyuki Nishimura, Sinji Abe, Hitoshi Satoh, Tetsuya Tomida, Naruomi Yasuda, Akiko Takayama, Tetsuo Inada, Tatuya Fujisaki, Shuichi Tazawa, Tatsuaki Kanai, Kiyomitsu Kawachi: "Simulation Study for Iterative Image Reconstruction including Multiple Coulomb Scattering Correction in Heavy Ion CT"Jpn J Med Phys.. 23[Suppl.3]. 266-269 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 安田成臣, 阿部慎司, 西村克之他: "残留飛程分布の測定による重イオン線CTのウィナースペクトルと相対電子密度分解能"Jpn J Med Phys.. 23. 209-219 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] Katsuyuki Nishimura, Shinji Abe, Hitoshi Sato et al.: "Evaluation of Spatial Resolution in Heavy Ion CT System"Jpn J Med Phys.. 23(suppl.2). 162-165 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] 安田成臣, 阿部慎司, 西村克之他: "残留飛程分布の測定による重イオン線CTのウィナースペクトルと相対電子密度分解能"Jpn J Med Phys.. 23(suppl.2). 166-169 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] Hiroshi Muraishi, Katsuyuki Nishimura, Sinji Abe, et al.: "Simulation Study for Iterative Image Reconstruction including Multiple Coulomb Scattering Correction in Heavy Ion CT"Jpn J Med Phys.. 23(suppl.2). 266-269 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] Nishimura K, Abe S, Sato H, et al.: "Development and Evaluation of Heavy Ion CT with Detection System of Screen and Image Intensified CCD"IFMBE Proceedings 4th Volume. 4(CD-ROM version). (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] Tetsuya Tomita, Katsuyuki Nishimura, et al.: "The performance of heavy ion CT system with fluorescent screen and CCD camera"Proceedings of The Third Korea-Japan Joint Meeting on Medical Physics. 432-435 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 富田哲也, 西村克之, 他: "重粒子線CTにおける撮像系の高速化"Jpn J Med Phys.. 22(suppl2). 160-163 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] Naruomi Yasuda, Shinji Abe, et al.: "The Noise Power Spectrum in Heavy Ion CT Based on Measurement of Residual Range Distribution"Proceedings of The Third Korea-Japan Joint Meeting on Medical Physics. 228-230 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] S.Abe, K.Nishimura, H Saitoh et al.: "Application of Imaging Plate to Measurement of Resolution for Heavy Ion Imaging"Jpn J.Med.Phys.. 21(52). 30-33 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] 富田哲也, 西村克之, 阿部慎司 他: "飛程分布測定による重粒子線CTのサイノグラムの作成"Jpn.J.Med.Phys.. 21(53). 180-183 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] 村石活, 西村克之, 小田千鶴 他: "逐次近似法による重粒子線CTの画像再構成"Jpn.J.Med.Phys.. 21(53). 176-179 (2001)

    • Related Report
      2001 Annual Research Report

URL: 

Published: 2001-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi