• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Fundamental and clinical evaluation of attenuation correcting using TCT on SPECT

Research Project

Project/Area Number 13670952
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionKumamoto University

Principal Investigator

TOMIGUCHI Seiji  Kumamoto University school of Medicine, lecturer, 医学部附属病院, 講師 (20172182)

Co-Investigator(Kenkyū-buntansha) KOJIMA Akihiro  Research center for RadioIsotope science, assistant Prof., アイソトープ総合センター, 助教授 (20161903)
Project Period (FY) 2001 – 2002
Project Status Completed (Fiscal Year 2002)
Budget Amount *help
¥3,100,000 (Direct Cost: ¥3,100,000)
Fiscal Year 2002: ¥1,500,000 (Direct Cost: ¥1,500,000)
Fiscal Year 2001: ¥1,600,000 (Direct Cost: ¥1,600,000)
Keywordsattenuation correction / SPECT / Tl-201 myocardial SPECT / scatter / image fusion / attenuation correction / image fusion / CT / 非対称ファンビームコリメータ / 201Tl心筋シンチグラフィ-
Research Abstract

Transmission computed tomography (TCT) with external radiation source was conventionally used for attenuation correction (AC). CT is recently used for AC instead of TCT. We evaluated the usefulness of TCT (TCT method) and CT (CT method) for the attenuation correction by a phantom and clinical study. In CT method, we also assessed the clinical usefulness of fused image (AC image with CT).
In TCT method, we used a 2-head gamma camera system equipped with asymmetric fan-beam collimator (GCA 7200, Toshiba) and the 3-head gamma camera equipped with fan-beam collimator (Prism 3000, Picker). We introduced a gantry-free gamma camera (SkyLight, ADAC) and multi-detector row CT (Lightspeed ultra, GE) in a same room as a CT/SPECT combined system. In CT method, we used this system.
In phantom study using a anthropomorphic phantom, both methods showed improvement in the uniformity of the distribution of Tl-201 in the myocardium. The contrast between the defect and normal myocardium was improved by the scatter correction.
In Tl-201 myocardial SPECT, there was the significant difference in specificity between non-corrected (NC) and AC images in the RCA territory and those in specificity and accuracy in the LCX territory. In the LAD territory, there were variable changes in sensitivity and specificity observed on between the AC images and the NC images.
Clinical usefulness of fused images was obtained in 84% (50/57) of cancer patients. Useful information on fused images was obtained in the diagnosis of staging and recurrence, differentiation of malignant from benign, and differentiation of pathological from physiological accumulation.
TCT method is useful for the attenuation correction on Tl-201 myocardial SPECT. Fused image made by CT method is useful for the nuclear studies of patients with cancer.

Report

(3 results)
  • 2002 Annual Research Report   Final Research Report Summary
  • 2001 Annual Research Report
  • Research Products

    (6 results)

All Other

All Publications (6 results)

  • [Publications] Seiji Tomiguchi, Yoichi Ohyama: "Diagnostic accuracy of simultaneous acquisition of transmission and emission data with technetium-99m transmission source on thallium-201 myocardial SPECT"Annals of Nuclear Medicine. 15. 21-26 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] Seiji Tomiguchi, Yoichi Ohyama: "Phantom Evaluation of Scatterand Attenuation Correction in Thallium-201/ Techetium-99m Acquistion in Myocardial Perfusion Single-photon Emission Computed Tomography"Radiation Medicine. 19. 81-87 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] Seiji Tomiguchi, A.Kojima: "Improvement of quantitative activity and image distortion in Tl-201 myocardial SPECT using scatter and attenuation corrections"Eur J Nucl Med (abstract). 29. S355 (2002)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] Seiji Tomiguchi, Yoichi Ohyama: "Diagnostic accuracy of simultaneous acquisition of transmission and emission data with technetium-99m transmission source on thallium-201 myocardial SPECT"Annals of Nuclear Medicine. VOL. 15. 21-26 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] Seiji Tomiguchi, Yoichi Ohyama: "Phantom Evaluation of Scattered and Attenuation Correction in Thallium-201/Technetium-99m Acquisition in Myocardial Perfusion Single-Photon Emission Computed Tomography"Radiation Medicine. VOL. 19. 81-87 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] A. Kojima, S. Tomiguchi: "Improvement of quantitative activity and image distortion in Tl-201 myocardial SPECT using scatter and attenuation correcting (abstract)"Eur J Nucl Med. 29. 5355 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2002 Final Research Report Summary

URL: 

Published: 2001-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi