• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Preventive method environmental oollution bv the air-borne bacteriain dentistry clinic.

Research Project

Project/Area Number 13672170
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field 矯正・小児・社会系歯学
Research InstitutionTOKYO DENTAL COLLEGE

Principal Investigator

SUYAMA Yuji  TOKYO DENTAL COLLEGE.Department of Dentistry. LECtURER, 歯学部, 講師 (10163065)

Co-Investigator(Kenkyū-buntansha) NAKANE Tomoo  (Nihon University). LECTURER, 大学院・生産工学・研究科電気工学専攻, 講師 (30059878)
YAMADA Yuji  ( Protection National Institute of Radiological Sciences) .PROFESSOR, 内部被ばく, 主任研究官 (20166739)
TAKAKU Satoru  Saitama College of Health . PROFESSOR, 短期大学部, 教授 (80154764)
IKEWAKI Nobunao  Kyusyu University of Health and welfare, ASSISTANT PROFESSOR, 保健学部, 助教授 (90193226)
Project Period (FY) 2001 – 2002
Project Status Completed (Fiscal Year 2002)
Budget Amount *help
¥3,500,000 (Direct Cost: ¥3,500,000)
Fiscal Year 2002: ¥1,400,000 (Direct Cost: ¥1,400,000)
Fiscal Year 2001: ¥2,100,000 (Direct Cost: ¥2,100,000)
Keywordsinfection control / medical facility / cleanness / indoor environment / aerosol / bacteria / pollution / Dental clinic
Research Abstract

Since the degree of air cleanness depends on the frequency of ventilation,correction fqr the frequency of ventilationwas performed in the establishment of standards. When results of measurement of air-borne bacteria in dental clinics were evaluated according to the tolerant concentration of air-hone bacteria in the U.S. Federal Standard No. 209 B, C, D, E clean rooms,the tolerant concentration was 2.5 cfu/ft3 for class 100,000 but the concentration in the investigated dental clinics was 1.4-32.8 cfu/'ft3. According to the tolerant concentrationproposedby theAmericanAssociationof Surgery (1978), 70%of the investigated dental dines and hospitals were classified as "contaminated surgery". According to the Standards of the JapanHospital Equipment Association (1998), most hospitals were classified as quasi-clean Or general clean areas. In the classification of the degree of air cleanliness associatedwith dental treatment, weighting of thedetectionrate (%) of aandgstreptococci maybenecessary. Accordingto thesestandardswithweighting,all dental clinics investigated in this study were "in an unfavorable state". We tested the eliminating effects by the new electric air cleaner within activated carbon systemwith the plaque solution aerosol . we developed an apparatus by incorporating the bactericidal function of white coal (coal obtained by burning at 800°C or more) with a very high minus potential on its surface into an HEPA filter-type air cleaner,and carried out amodel experiment on its effects in a clean booth. Good results were obtained with an eradication rate of 90% or more for filamentous fungi, coagulase (-) staphylococci, non-fer'mentative rods,Staphylococcus aureus, Bacillus sp, Microcossus sp, Streptococcus sp, Gram-negative rods> Gram-positive rods, Gram- positive cocci, and a-hemolytic streptococci.

Report

(3 results)
  • 2002 Annual Research Report   Final Research Report Summary
  • 2001 Annual Research Report
  • Research Products

    (7 results)

All Other

All Publications (7 results)

  • [Publications] 須山祐之: "歯科診療施設での空気感染に対する実践的な感染対策(その1)"口腔衛生学会雑誌. 51・4. 456-457 (2001)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] 須山祐之: "保育施設における化学物質による室内汚染に関する検討"日本公衆衛生雑誌. 49・10. 931 (2002)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] 須山祐之: "保育施設の室内環境汚染状況とその対策"歯科学報. 102・10. 810 (2002)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] 須山祐之: "歯科診療施設での空気感染に対する実践的な感染対策(その1)"口腔衛生学会雑誌. 51・4. 456-457 (2001)

    • Related Report
      2002 Annual Research Report
  • [Publications] 須山祐之: "保育施設における化学物質による室内汚染に関する検討"日本公衆衛生雑誌. 49・10. 931 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 須山祐之: "保育施設の室内環境汚染状況とその対策"歯科学報. 102・10. 810 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 須山祐之: "ドクターの目にやさしい歯科医療を求めて、第3章目にやさしい診療環境とツール、1.診療室の空調"デンタルダイヤモンド. 26・365. 26-31 (2001)

    • Related Report
      2001 Annual Research Report

URL: 

Published: 2001-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi