• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of 3D micron-CT to observe the interior of cells with high space resolving power and high-speed photograph

Research Project

Project/Area Number 13852017
Research Category

Grant-in-Aid for Scientific Research (S)

Allocation TypeSingle-year Grants
Research Field Nuclear engineering
Research InstitutionTohoku University

Principal Investigator

ISHII Keizo  東北大, 工学(系)研究科(研究院), 教授 (00134065)

Co-Investigator(Kenkyū-buntansha) YAMAZAKI Hiromichi  Tohoku University, Graduate School of Engineering, Associate Professor, 大学院工学研究科, 助教授 (00166654)
KIKUCHI Youhei  Tohoku University, Graduate School of Engineering, Technical Assistant, 大学院工学研究科, 教務職員 (50359535)
MATSUYAMA Shigeo  Tohoku University, Graduate School of Engineering, Research Associate, 大学院工学研究科, 助手 (70219525)
Project Period (FY) 2001 – 2004
Project Status Completed (Fiscal Year 2005)
Budget Amount *help
¥112,190,000 (Direct Cost: ¥86,300,000、Indirect Cost: ¥25,890,000)
Fiscal Year 2005: ¥2,990,000 (Direct Cost: ¥2,300,000、Indirect Cost: ¥690,000)
Fiscal Year 2004: ¥18,850,000 (Direct Cost: ¥14,500,000、Indirect Cost: ¥4,350,000)
Fiscal Year 2003: ¥9,360,000 (Direct Cost: ¥7,200,000、Indirect Cost: ¥2,160,000)
Fiscal Year 2002: ¥24,830,000 (Direct Cost: ¥19,100,000、Indirect Cost: ¥5,730,000)
Fiscal Year 2001: ¥56,160,000 (Direct Cost: ¥43,200,000、Indirect Cost: ¥12,960,000)
Keywordsmicron-CT / 3D image / micro-PIXE / in-vivo / Ti-K-X-ray / visible light / ant / 3次元ミクロンCT / アイテレーション法 / 光CT / PIXE / マイクロビーム / X線CCDカメラ / マイクロ粒子ビーム
Research Abstract

We developed "micron-CT", using micro-PIKE for in-vivo imaging. This system comprises an X-ray CCD camera with high resolution (pixel size : 8x8μm^2, number of pixels : 1000x1000) and an X-ray point source with a spot size of 1.5x1.5μm^2 which is generated by irradiation of a microbeam on a pure metal target. The sample is placed in a tube of a small diameter, and rotated by a stepping motor. The 3D images were reconstructed from the obtained projection data by using a cone-beam CT reconstruction algorithm. We applied this micron-CT to investigate the internal structure of small ant. Ti was used as an X-ray target considering detection. efficiency of the CCD camera. An ant after formalin-fixation was inserted into a micron tube. The 3D images of ant's head were obtained with 6 μm spatial resolution and the internal structure is clearly seen. Furthermore, we developed a method to measure an ant in-vivo. The ant was anaesthetized by chloroform and then it was inserted into the micron tube. The inside of the tube is kept in atmospheric pressure and enabled to measure in-vivo. There is a large difference on the images between the fixed ant and the living one. In the case of fixed ant, the brain shrank and something was washed out due to formalin-fixation. Because the CCD is sensitive to visible light, we also examined the capability of light micron-CT using visible red lights from an Al_2O_3(Cr) ruby scintillator and applied it to investigate a small red thick. Obscure images were obtained due to the dispersion of lights. The 3D micron-CT can provide cross sectional images of in-vivo samples with high spatial resolution and will be useful for biological studies.

Report

(5 results)
  • 2004 Annual Research Report   Final Research Report Summary
  • 2003 Annual Research Report
  • 2002 Annual Research Report
  • 2001 Annual Research Report
  • Research Products

    (25 results)

All 2005 2004 Other

All Journal Article (11 results) Publications (14 results)

  • [Journal Article] Development of an image reconstruction method for Micron-CT using PIXE2005

    • Author(s)
      T.Yamaguchi et al.
    • Journal Title

      International Journal of PIXE 15(3&4)

      Pages: 195-202

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] MICRON-CT USING PIXE WITH MICRO-BEAMS2005

    • Author(s)
      K.Ishii et al.
    • Journal Title

      International Journal of PIXE 15(3&4)

      Pages: 111-124

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Microbeam Analysis of Single Aerosol Particles2005

    • Author(s)
      S.Matsuyama et al.
    • Journal Title

      International Journal of PIXE 15(3&4)

      Pages: 257-262

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Microbeam Analysis at Tohoku University for Biological Studies2005

    • Author(s)
      S.Matsuyama et al.
    • Journal Title

      International Journal of PIXE 15(1&2)

      Pages: 41-46

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Contribution of Atomic Bremsstrahlung in PIXE spectra and screening effect in atomic bremsstrahlung2005

    • Author(s)
      K.Ishii et al.
    • Journal Title

      Χ-ray Spectrometry 34

      Pages: 363-365

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Contribution of Atomic Bremsstrahlung in PIXE spectra and screening effect in atomic bremsstrahlung2005

    • Author(s)
      K.Ishii et al.
    • Journal Title

      X-ray Spectrometry 34

      Pages: 363-365

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Microbeam Analysis System at Tohoku University2004

    • Author(s)
      S.Matsuyama et al.
    • Journal Title

      International Journal of PIXE 14(1&2)

      Pages: 1-8

    • Related Report
      2004 Annual Research Report
  • [Journal Article] PIXE Analysis of Water Leakage from a Landfill Site of Industrial Waste-Generationg Hydrogen Sulfide2004

    • Author(s)
      H.Yamazaki et al.
    • Journal Title

      International Journal of PIXE 14(1&2)

      Pages: 57-66

    • Related Report
      2004 Annual Research Report
  • [Journal Article] Behavior of Pet Foil Used as Beam Extraction Window During Irradiation at Atmospheric Pressure2004

    • Author(s)
      Y.Barbotteau et al.
    • Journal Title

      International Journal of PIXE 14(1&2)

      Pages: 19-26

    • Related Report
      2004 Annual Research Report
  • [Journal Article] The Elemental Analysis of IgE-Sensitized RBL-2H3 Cells Using In-Air Micro PIXE2004

    • Author(s)
      K.Mizuma et al.
    • Journal Title

      International Journal of PIXE 14(1&2)

      Pages: 27-34

    • Related Report
      2004 Annual Research Report
  • [Journal Article] Mapping of Heavy Metals Accumulated in Plants Using Submilli-PIXE Camera2004

    • Author(s)
      R.Watanabe et al.
    • Journal Title

      【photograph】International Journal of PIXE 14(1&2)

      Pages: 35-42

    • Related Report
      2004 Annual Research Report
  • [Publications] S.Matsuyama, K.Ishii, et al.: "Preliminary Results of microbeam at Tohoku University"Nuclear Instruments and Methods in Physics Research B. 210. 59-64 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] Y.Oishi, K.Hotta, K.Ishii, et al.: "3D imaging of elemental distributions usmg multi angle RBS 2D-data"Nuclear Instruments and Methods in Physics Research B. 210. 117-122 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] T.Satoh, K.Ishii, et al.: "Development of a large-solid-angle and multi-device detection system for elemental analysis"Nuclear Instruments and Methods in Physics Research B. 210. 113-116 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] K.Ishii, H.Yamazaki, S.Matsuyama, Y.Kikuchi: "Establishment of Central Research Laboratory for Accurate Quantitative PIXE Analysis -An Approach of Tohoku University-"International Journal of PIXE. 13. 17-22 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] S.Matsuyama, K.Katoh, S.Sugihara, K.Ishii, et al.: "Multi-site Aerosol Monitoring Using Mini Step Sampler"International Journal of PIXE. 13. 65-80 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] H.Yamazaki, K.Ishii, S.Matsuyama, et al.: "Summary of the Workshop on Practical Problems in Biological Application of Micro-PIXE Analysis"International Journal of PIXE. 13. 89-96 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] 松澤大樹, 石井慶造 他: "目で見る脳とこころ"日本放送出版協会. 278 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] S.Harada et al.: "The kinetics of Fe and Ca for the development of radiation-induced apoptosis by micro-PIXE imaging"Nuclear Instrument and Methods in Physics Research B. 189. 437-442 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] Takuro Sakai et al.: "JAERI Takasaki in-air micro-PIXE system for various applications"Nuclear Instrument and Methods in Physics Research B. 190. 271-275 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] A.Tanaka et al.: "In-Air Micro-PIXE Analysis of Tissue Samples"International Journal of PIXE. 12(In press). (2003)

    • Related Report
      2002 Annual Research Report
  • [Publications] M.Rodriguez et al.: "Preliminary measurements of the low energy detection efficiency of a Si(Li) detector for PIXE applications"International Journal of PIXE. 12(In press). (2003)

    • Related Report
      2002 Annual Research Report
  • [Publications] K.Ishii, A.Sugimoto, A.Tanaka, et al.: "Elemental analysis of cellular samples by in-air micro-PIXE"Nuclear Instrument and Methods in Physics Research B. 181. 448-453 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] T.Satoh, K.Ishii: "Calculation of Cross Sections of M-Shell Atomic Bremsstrahlung"International Journal of PIXE. 11. 45-48 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] T.Satoh, K.Ishii, S.Matsuyama, H.Yamazaki, et al.: "Investigation on the Influence of Back Scattered Protons in PIXE Spectrum"International Journal of PIXE. 11. 49-59 (2001)

    • Related Report
      2001 Annual Research Report

URL: 

Published: 2001-04-01   Modified: 2017-05-19  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi