Project/Area Number |
14404009
|
Research Category |
Grant-in-Aid for Scientific Research (B)
|
Allocation Type | Single-year Grants |
Section | 海外学術 |
Research Field |
Building structures/materials
|
Research Institution | Nagoya City University |
Principal Investigator |
AOKI Takayoshi Nagoya City University, Graduate School of Design and Architecture, Associate Professor, 大学院・芸術工学研究科, 助教授 (10202467)
|
Co-Investigator(Kenkyū-buntansha) |
YUASA Noboru Nihon University, College of Industrial Technology, Associate Professor, 生産工学部, 助教授 (00230607)
KOMIYAMA Tatsuhito Constec.Eng.Co., Ltd., Senior Researcher, 大阪診断技術研究所, 所長
TANIGAWA Yasuo Nagoya City University, Graduate School of Environmental Studies, Professor, 大学院・環境学研究科, 教授 (70023182)
HAMASAKI Hitoshi Building Research Institute, Senior Researcher, 材料研究グループ, 主任研究員 (30370703)
小浜 芳朗 名古屋市立大学, 大学院・芸術工学研究科, 教授 (50023304)
宮村 篤典 名古屋市立大学, 大学院・芸術工学研究科, 教授 (20076532)
|
Project Period (FY) |
2002 – 2003
|
Project Status |
Completed (Fiscal Year 2003)
|
Budget Amount *help |
¥9,000,000 (Direct Cost: ¥9,000,000)
Fiscal Year 2003: ¥4,300,000 (Direct Cost: ¥4,300,000)
Fiscal Year 2002: ¥4,700,000 (Direct Cost: ¥4,700,000)
|
Keywords | International researcher interchange / Italy / Sanctuary of Vicoforte / Masonry / Deterioration / Repair / Non-destructive test / Structural analysis |
Research Abstract |
The objectives of this study are a)diagnaostic inspection of deterioration of the Sanctuary of Vicoforte and some related historical structures by visual observation and non-destructive tests, b)structural and dynamic investigation, and c)interpretation of the static and dynamic behaviors of the dome by FEM. This work is a part of the surveying project "Vicoforte 2002-2006" as a joint research between Japanese and Italian scholars of Politecnico di Torino. 1.Delamination of stone finishing and fresco painting are detected by visual observation and Radiation Thermometer. 2.The thickness of the main dome and vaults are estimated by Electromagnetic Radar. 3.Impact Echo Scanner is applied to estimate the continuity of iron ties embedded at the base of the main dome and they are probably continuous. 4.Concrete Test Hammer, Scratch Tester, Simple water absorption test, Windsor Pin System are applied to estimate the compressive strength and Young's modulus of the brick and the mortar. Estimation of durability for the brick and the stone by Freezing and thawing method are also applied. 5.From the microtremor measurement, the fundamental frequency of the dome is estimated. 6.The load bearing mechanism and crack pattern of the structure are clarified by FEA. 7.Non-destructive tests are applied to diagnostic inspection of deterioration of the chapel of Sindone and airship Hangar and from the microtremor measurement, the fundamental frequencies are estimated. 8.Monitoring of temperature, inclination of the wall, cracks, and tension of the wire of he Hangar are started. 9.Diagnostic inspection of deterioration of Rakanji stone arch bridge, Oita, and the brick chimneys, Tokoname, are carried out and from the dynamic test, natural frequencies and modes are estimated. Earthquake resistance efficiency of the brick chimneys is evaluated. Dynamic test of the traditional timber temples are also carried out and their dynamic characteristics are clarified.
|