• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Mapping of Elasticity With Nano-Meter Resolution Using a Mass-Concentrated Cantilever in Atomic Force Acoustic Microscopy

Research Project

Project/Area Number 14550065
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Materials/Mechanics of materials
Research InstitutionAkita University

Principal Investigator

MURAOKA Mikio  Akita University, Faculty of Engineering and Resource Science, Associate Professor, 工学資源学部, 助教授 (50190872)

Project Period (FY) 2002 – 2003
Project Status Completed (Fiscal Year 2003)
Budget Amount *help
¥3,200,000 (Direct Cost: ¥3,200,000)
Fiscal Year 2003: ¥1,200,000 (Direct Cost: ¥1,200,000)
Fiscal Year 2002: ¥2,000,000 (Direct Cost: ¥2,000,000)
KeywordsAtomic Force Acoustic Microscopy / Mass-concentrated cantilevers / Manning of elasticity / Contact resonance / Tip coating / Ratio of mass / Evaluation of local elasticity / Flat-ended tip / ナノ分解能弾性分布画像 / 圧電セラミックス / 探針接触角 / 微弱加振力 / ナノ分解能
Research Abstract

Near-field acoustic microscopy such as atomic force acoustic microscopy (AFAM) is a promising technique of imaging and evaluating such local elasticity. In AFAM, the resonant frequency of a micro-cantilever equipped with a sensor tip gives a measure of the contact stiffness between a sample and a tip. For stiff samples like metal and ceramics, AFAM is confronted with significantly low sensitivity. A mass-concentrated (MC) cantilever proposed by Muraoka gives an ideal solution for the problem.
This study refined the technique of MC cantilevers so as to work stably without abrupt failures of its functions. The results are summarized as follows :
1.Small amplitudes of the cantilever are recommended so that many parasite resonant peaks are depressed.
2.Ductile coating such as Ti/Pt prefers for the tip rather than brittle coating like W_2C. The latter is very hard but easily delaminated. In contrast the ductile coating prolong the lifetime of the tip.
Quantitative evaluation of elasticity using MC cantilevers also was discussed in this study.
3.A flat-ended tip greatly simplifies the evaluation. The contact area is kept constant with the contact stiffness independent of the adhesion force and the contact force. The present method using a MC cantilever and a flat-ended tip gives a good evaluation with less than one percent of error for standard samples, diamond and etched Si wafers, having well-defined elastic coefficients for its surface, layers.
4.The MC cantilever and a flat-end tip also demonstrated very sharp images reflecting sample elasticity for Co-Cr thin film in hard disks, PZT thin film, deposited carbon film, and Ti sheet. Fatigued surfaces of Ti sheets also were examined for nano-structures such as dislocation piling or slip bands.

Report

(3 results)
  • 2003 Annual Research Report   Final Research Report Summary
  • 2002 Annual Research Report
  • Research Products

    (19 results)

All Other

All Publications (19 results)

  • [Publications] Muraoka M.: "Simple Evaluation of Elasticity in Nano-Meter Scale Using a Flat-Ended Sensor Tip in Sensitivity-Enhanced Atomic Force Acoustic Microscopy"Proc. 11th Int. Conf. on Fracture. (CD-ROM)(掲載予定). (2005)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 村岡 幹夫: "マイクロジェットを利用したAFMカンチレバーのばね定数計測"日本機械学会論文集(A編). 70. 168-174 (2004)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Muraoka, M.: "Sensitive Mapping of Nano-Scale Elasticity Using Contact Resonance of a Mass-Concentrating AFM Cantilever"Proc. of Int. Conf. on Advanced Technology in Experimental Mechanics 2003, Sept. 10-12, Nagoya. No.OS05W0282(CD-ROM). 1-5 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 村岡 幹夫: "原子間力超音波顕微鏡の高感度化による硬質ナノ組織の観察"日本機械学会M&M2003材料力学部門講演会. No.03-11. 817-818 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 村岡 幹夫: "ハニカムリンク・アクチュエータの提案"精密工学会東北支部学術講演会講演論文集. 63-64 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Muraoka, M.: "Sensitive Detection of Local Elasticity by Oscillating an AFM Cantilever with Its Mass Concentrated"JSME Int. J., Ser. A. 45. 567-572 (2002)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Muraoka M.: "Simple Evaluation of Elasticity in Nano-Meter Scale Using a Flat-Ended Sensor Tip in Sensitivity-Enhanced Atomic Force Acoustic Microscopy"Proc.11th Int.Conf.on Fracture. (CD-ROM),(to be published). (2005)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Muraoka, M.: "A New Method of Evaluating the Force Constants of AFM Cantilevers by Using Micro Jet Force"Trans.JSME, Ser.A. Vol.70-No.689. 168-172 (2004)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Muraoka, M.: "Sensitive Mapping of Nano-Scale Elasticity Using Contact Resonance of a Mass-Concentrating AFM Cantilever"Proc.of Int.Conf.on Advanced Technology in Experimental Mechanics 2003, Sept.10-12;Nagoya. CD-ROM, No.OS05W0282. 1-55 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Muraoka, M.: "Observation of Nano-Structured Stiff Materials by Sensitivity-Enhanced Atomic Force Acoustic Microscopy"Proc.2003 Annual Meeting of JSME/MMD. No.03-11. 817-818 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] M.Muraoka: "Piezo-Actuator amplified by Honeycomb-Link Mechanism"Proc.2002 Meeting of JSP(Ichinoseki). 63-64 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Muraoka, M.: "Sensitive Detection of Local Elasticity by Oscillating an AFM Cantilever with Its Mass Concentrated"JSME Int.J.,Ser.A. Vol.45-No.4. 567-572 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 村岡幹夫, 眞田 慎: "マイクロジェットを利用したAFMカンチレバーのばね定数計測"日本機械学会論文集(A編). 70・689. 168-174 (2004)

    • Related Report
      2003 Annual Research Report
  • [Publications] Muraoka, M., Kamata, H.: "Sensitive Mapping of Nano-Scale Elasticity Using Contact Resonance of a Mass-Concentrating AFM Cantilever"Proc.of Int.Conf.on Advanced Technology in Experimental Mechanics 2003, Sept.10-12, Nagoya, CD-ROM. No.OS05W0282. 1-5 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] 村岡幹夫, 小松慎司: "原子間力超音波顕微鏡の高感度化による硬質ナノ組織の観察"日本機械学会M&M2003材料力学部門講演会. No.03-11. 817-818 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] 村岡幹夫, 小野寺信雄, 眞田慎: "ハニカムリンク・アクチュエータの提案"精密工学会東北支部学術講演会講演論文集. 63-64 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] Mikio MURAOKA, Hiroki KAMATA: "Nanometer-resolution Mapping of Local Elasticity by a Sensitive AFM Cantilever with Its Mass Concentrated(Invited paper)"Proc. 2nd Int. Symp. on Instrumentation Science and Technology, Jinan. Vol.2. 21-24 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 村岡幹夫, 鎌田裕毅: "高感度原子間力超音波顕微鏡によるナノ分解能弾性マッピング"第46回日本学術会議材料研究連合講演会講演論文集. 339-340 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] Mikio MURAOKA: "Sensitive Detection of Local Elasticity by Oscillating an AFM Cantilever with Its Mass Concentrated"JSME Int. J., Ser. A. Vol.45,No.4. 567-572 (2002)

    • Related Report
      2002 Annual Research Report

URL: 

Published: 2002-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi