A Study on a Cochlear Implant System based on a Reverse Solution of the Peripheral Auditory Model

Research Project

Project/Area Number 14550354
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field 情報通信工学
Research InstitutionShizuoka University

Principal Investigator

KITAZAWA Shigeyoshi  Shizuoka University, Department of Computer Science, Professor, 情報学部, 教授 (00109018)

Co-Investigator(Kenkyū-buntansha) IWASAKI Satoshi  Hamamatsu University, School of Medicine, Oto., Lec., 医学部, 講師 (00232653)
KIRIYAMA Shinya  Shizuoka University, Department of Computer Science, Research Associate, 情報学部, 助手 (20345804)
Project Period (FY) 2002 – 2003
Project Status Completed (Fiscal Year 2003)
Budget Amount *help
¥3,100,000 (Direct Cost: ¥3,100,000)
Fiscal Year 2003: ¥1,300,000 (Direct Cost: ¥1,300,000)
Fiscal Year 2002: ¥1,800,000 (Direct Cost: ¥1,800,000)
KeywordsCochlear Implant / CI stimulated sound / strategy / Cochlea / ACE / CSPE / 音響シミュレーション / インタビュー
Research Abstract

As a consequence of continuous developments of acoustic simulation on the speech processing strategy of the cochlear implant system in order to achieve higher quality of the transmitted speech quality, we interviewed and questionnaire surveys with help of the doctor in charge of the implantees to find out that the perceptual speech sound through the cochlear implant is much better than that of the acoustic simulation. Hearing from implantees at the time of the first switch-on, implantees hear noisy speech at the beginning, but the noise disappears after several minutes they hear clean speech. This finding suggests that the peripheral auditory system has unknown capability to adapt to the initial noisy speech to result in clean speech.
Experiments on auditory perception via acoustic simulation of cochlear implant speech processing strategies of SPEAKS method and Multi-pulse coding had been conducted. Experiments on cochlear impantees had been conducted as well. The results show that perception of cochlear implantees are lower than SPEAKS method and higher than multi-pulse coding measured by acoustic simulation.
In order to validate effectiveness of this strategy, we have conducted a series of perceptual experiments on implantees in the Hamamatsu medical university, with supports from Mr. Brett Swanson an senior engineer of the Cochlear Co.. Implantees heard electric stimulation from the electrode fitting equipments under supervision of a co-researcher Dr. Iwasaki who is in charge of the patients. The ACE stimulation electrode patterns are regarded to be suitable for the patients because they are used to them. Patients could adapt to our new strategy in a very short time, during a one experimental session of a half hour, to show significantly better perceptual results. These results suggest much better performance under continuous usage of the new strategy. The resultant strategy was patent applied and presented as a journal paper.

Report

(3 results)
  • 2003 Annual Research Report   Final Research Report Summary
  • 2002 Annual Research Report
  • Research Products

    (27 results)

All Other

All Publications (27 results)

  • [Publications] E.Dashtseren: "Evaluation of a novel signal processing strategy for Cochlear Implant speech processors"IEICE Transactions on Information and Systems. E87-D,2. 463-471 (2004)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Dashtseren Erdenebat: "An Alternative Channel Selection Algorithm Based on Energy for Multichannel Cochlear Implant Speech Processors"日本音響学会2002年秋季研究発表会講演論文集. 467-468 (2002)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 松本浩敬: "マルチパルス符号化法における聴取実験評価"日本音響学会2002年秋季研究発表会講演論文集. 427-428 (2002)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Erdenebat Dashtseren: "Study of effect of low-pass filtering for channels amplitude estimation on speech intelligibility by acoustic simulation of SPEAK strategy"J.Acoust.Soc.Am.. 111,5. 2430-2430 (2002)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] 松本浩敬: "人工内耳装用者の単音節聴取実験評価"日本音響学会2003年春季研究発表会講演論文集. 529-530 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Erdenebat Dashtseren: "A channel selection by pulse estimation algorithm for cochlear implant systems"Proceedings of Autumn meeting of ASJ. 435-436 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Erdenebat Dashtseren: "Comparison of two signal processing strategies using consonant recognition tests"4th Asia Pacific Symposium on Cochlear Implant and related sciences. 158-158 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Dashtseren: "A New Signal Processing Strategy for Cochlear Implant speech processors"Technical Report of IEICE. SP 2003-193. 1-6 (2004)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] E.Dashtseren: "Effects of Variability of Stimulation Rate and Order on Speech Recognition Performance of Cochlear Implant Patients"The 18^<th> ICA 2004. I. 807-810 (2004)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] E.Dashtseren: "Evaluation of a novel signal processing strategy for Cochlear Implant speech processors"IEICE Transactions on Information and Systems. E87-D,2. 463-471 (2004)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Dashtseren Erdenebat: "An Alternative Channel Selection Algorithm Based on Energy for Multichannel Cochlear Implant Speech Processors"The Autumn Meeting of the Acoustical Society of Japan. 467-468 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Hirotaka Matsumoto, Yasuyuki Kawai, Dashtseren Erdenebat, Shinya Kiriyama, Shigeyoshi Kitazawa: "An acoustically simulated listening test on multipulse coding strategy"The Autumn Meeting of the Acoustical Society of Japan. 427-428 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Erdenebat Dashtseren: "Study of effect of low-pass filtering for channels amplitude estimation on speech intelligibility by acoustic simulation of SPEAK strategy"J.Acoust.Soc.Am.. 111,5. 2430 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Hirotaka Matsumoto, Dashtseren Erdenebat, Shinya Kiriyama, Shigeyoshi Kitazawa: "A CV syllable linstening test and evaluation on Cochlear Implant Patients"The Spring Meeting of the Acoustical Society of Japan. 529-530 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Erdenebat Dashtseren: "A channel selection by pulse estimation algorithm for cochlear implant systems"Proceedings of Autumn meeting of ASJ. 435-436 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] Erdenebat Dashtseren: "Comparison of two signal processing strategies using consonant recognition tests"4th Asia Pacific Symposium on Cochlear Implant and related sciences. 158-158 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] E.Dashtseren: "A New Signal Processing Strategy for Cochlear Implant speech processors"Technical Report of IEICE. SP2003-193. 1-6 (2004)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] E.Dashtseren: "Effects of Variability of Stimulation Rate and Order on Speech Recognition Performance of Cochlear Implant Patients"The 18^<th> ICA 2004. I-807-I-810 (2004)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2003 Final Research Report Summary
  • [Publications] E.Dashtseren: "Evaluation of a novel signal processing strategy for Cochlear Implant speech processors"IEICE Transactions on Information and Systems. E87-D, 2. 463-471 (2004)

    • Related Report
      2003 Annual Research Report
  • [Publications] 松本浩敬: "人工内耳装用者の単音節聴取実験評価"日本音響学会2003年春季研究発表会講演論文集. 529-530 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] Erdenebat Dashtseren: "A channel selection by pulse estimation algorithm for cochlear implant systems"Proceedings of Autumn meeting of ASJ. 435-436 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] Erdenebat Dashtseren: "Comparison of two signal processing strategies using consonant recognition tests"4th Asia Pacific Symposium on Cochlear Implant and related sciences. 111, 5. 26 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] E.Dashtseren: "A New Signal Processing Strategy for Cochlear Implant speech processors"Technical Report of IEICE. SP2003-193. 1-6 (2004)

    • Related Report
      2003 Annual Research Report
  • [Publications] E.Dashtseren: "Effects of Variability of Stimulation Rate and Order on Speech Recognition Performance of Cochlear Implant Patients"The 18^<th> ICA 2004, Kyoto. 75 (2004)

    • Related Report
      2003 Annual Research Report
  • [Publications] Dashtseren Erdenebat, Kiriyama Shinya, Kitazawa Shigeyoshi: "An Alternative Channel Selection Algorithm Based on Energy for Multichannel Cochlear Implant Speech Processors"日本音響学会2002年秋季研究発表会講演論文集. 467-468 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 松本浩敬, 河合恭幸, D.Erdenebat, 桐山伸也, 北澤茂良: "マルチパルス符号化法における聴取実験評価"日本音響学会2002年秋季研究発表会講演論文集. 427-428 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] 松本浩敬, D.Erdenebat, 桐山伸也, 北澤茂良, 岩崎 聡: "人工内耳装用者の単音節聴取実験評価"日本音響学会2003年春季研究発表会講演論文集. 529-530 (2003)

    • Related Report
      2002 Annual Research Report

URL: 

Published: 2002-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi