• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Application of Imaging Plate to Quality Control of Heavy Ion Therapy

Research Project

Project/Area Number 14570872
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionIbaraki Prefectural University of Health Sciences

Principal Investigator

ABE Shinji  Ibaraki Prefectural University of Health Sciences, School of Health Sciences, Professor, 保健医療学部, 教授 (00274978)

Co-Investigator(Kenkyū-buntansha) NISHIMURA Katsuyuki  Ibaraki Prefectural University of Health Sciences, School of Health Sciences, Professor, 保健医療学部, 教授 (10129158)
INADA Tetsuo  Ibaraki Prefectural University of Health Sciences, School of Health Sciences, Professor, 保健医療学部, 教授 (50114038)
SATO Hitoshi  Ibaraki Prefectural University of Health Sciences, School of Health Sciences, Associate Professor, 保健医療学部, 助教授 (90285057)
FUJISAKI Tatsuya  Ibaraki Prefectural University of Health Sciences, School of Health Sciences, Associate Professor, 保健医療学部, 助教授 (00285058)
SAITOH Hidetoshi  Tokyo Metropolitan University of Health Sciences, School of Health Sciences, Associate Professor, 保健科学部, 助教授 (50196002)
Project Period (FY) 2002 – 2004
Project Status Completed (Fiscal Year 2004)
Budget Amount *help
¥3,500,000 (Direct Cost: ¥3,500,000)
Fiscal Year 2004: ¥800,000 (Direct Cost: ¥800,000)
Fiscal Year 2003: ¥1,200,000 (Direct Cost: ¥1,200,000)
Fiscal Year 2002: ¥1,500,000 (Direct Cost: ¥1,500,000)
Keywordsimaging plate / heavy ion radiography / characteristic curve / multiple scattering / scattering radiograph / heavy ion therapy / quality control / residual range distribution / コントラスト伝達関数 / 周波数特性 / エッジ強調 / CCDカメラ / 重粒子線CT / 電子密度分布 / 電子密度分解能 / 重荷電粒子線CT / 解像力特性
Research Abstract

The aim of this research project is to fundamentally study applications of imaging plate (IP) to quality control of the heavy ion radiation therapy.
In fiscal year 2002, we evaluated the image quality of the heavy ion radiography with IP as a tool for quality control of the heavy ion radiation therapy. Characteristic curves of IP for heavy ions were straight lines, similarly to X-rays. The lateral straggling of heavy ion passing through the material was approximately represented as a Gaussian distribution.
In fiscal year 2003, we discussed the measurement methods of residual rage distribution with the IP and the intensifying screen-II CCD camera system. The two methods lead to similar results. Furthermore, the electron density resolution of heavy ion CT image was estimated by the 1 dimensional Wiener spectrum obtained from the fluctuation of residual range distribution for a projection angle. The result is consistent with the one obtained form the density resolution phantom. Therefore, it was considered that the measurement with the IP was useful.
In fiscal year 2004, we evaluated the image quality of the heavy ion scattering radiography with IP. A square wave chart (Model No.1, KYOKKO) was used in the experiment. As a result, the image resolution was able to be superior to the conventional heavy ion radiography due to an edge enhancement arose from the scattering of heavy ions with the material.

Report

(4 results)
  • 2004 Annual Research Report   Final Research Report Summary
  • 2003 Annual Research Report
  • 2002 Annual Research Report
  • Research Products

    (8 results)

All 2004 2003 2002 Other

All Journal Article (4 results) Publications (4 results)

  • [Journal Article] Noise Reduction in heavy Ion CT using wavelet shrinkage2004

    • Author(s)
      Naruomi Yasuda, Shinji Abe, et al.
    • Journal Title

      Jpn J Med Phys 24[Suppl.2]

      Pages: 43-44

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Noise Reduction in heavy Ion CT using wavelet shrinkage2004

    • Author(s)
      Naruomi Yasuda, Shinji Abe, Katsuyuki Nishimura, et al.
    • Journal Title

      Jpn J Med Phys 24[Suppl.2]

      Pages: 43-44

    • Related Report
      2004 Annual Research Report
  • [Journal Article] Application of imaging plate to focal-spot measurement2003

    • Author(s)
      Masaya Noguchi, Shinji Abe, et al.
    • Journal Title

      Jpn J Med Phys 23[Suppl.2]

      Pages: 31-34

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] The Noise Power Spectrum in Heavy Ion CT Based on Measurement of Residual Range Distribution2002

    • Author(s)
      Naruomi Yasuda, Shinji Abe, et al.
    • Journal Title

      Proceedings of The Third Korea-Japan Joint Meeting on Medical Physics

      Pages: 228-230

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Publications] Masaya Noguchi, et al.: "Application of imaging plate to focal-spot measurement"Jpn J Med Phys. 23・Sup.2. 31-34 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] 安田成臣, 他: "残留分布の測定による重イオン線CTのウィナースペクトルと相対電子密度分解能"Jpn J Med Phys. 23・4. 209-219 (2003)

    • Related Report
      2003 Annual Research Report
  • [Publications] Shinji Abe, et al.: "Heavy ion CT system based on measurement of residual range distribution"Jpn J Med Phys. 22・1. 1-9 (2002)

    • Related Report
      2002 Annual Research Report
  • [Publications] Naruomi Yasuda, et al.: "The Noise Power Spectrum in Heavy Ion CT Based on Measurement of Residual Range Distribution"Proceedings of The Third Korea-Japan Joint Meeting on Medical Physics. 228-230 (2002)

    • Related Report
      2002 Annual Research Report

URL: 

Published: 2002-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi