Automatic virtual transducer locating system to assist interpreting ultrasound imaging
Project/Area Number |
15500346
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
Medical systems
|
Research Institution | JICHI MEDICAL SCHOOL |
Principal Investigator |
ONO Tomoko JMS, School of Medicine, Research Fellow, 医学部, 研究員 (40347993)
|
Co-Investigator(Kenkyū-buntansha) |
TANIGUCHI Nobuyuki JMS, School of Medicine, Associate Professor, 医学部, 助教授 (10245053)
ITOH Kouichi JMS, School of Medicine, Professor, 医学部, 教授 (60095007)
|
Project Period (FY) |
2003 – 2005
|
Project Status |
Completed (Fiscal Year 2005)
|
Budget Amount *help |
¥2,700,000 (Direct Cost: ¥2,700,000)
Fiscal Year 2005: ¥400,000 (Direct Cost: ¥400,000)
Fiscal Year 2004: ¥400,000 (Direct Cost: ¥400,000)
Fiscal Year 2003: ¥1,900,000 (Direct Cost: ¥1,900,000)
|
Keywords | Ultrasonography / Magnetic sensor / 3D / bodymark / 超音波 / 磁場センサー / 産婦人科 / 動画 / 探触子 / 三次元表示 / 磁場センサ / 腹部 / 頚部 / コンピュータグラフィックス |
Research Abstract |
Ultrasonography is used over the world in clinical. One of the important merits of ultrasonography is free from the ordinary sections, and we can show ultrasound images depending on the organs or tumors appropriately, which is not familiar with other modalities. To interpret the recorded images, we often use the bodymark to show the direction and angle of the probe. However even we use this bodymark it is not easy to show the ultrasonic image sections at moving transducer. The purpose of this research is to show the mark of transducer's position and plane on the constructed 3 dimensional bodymark, which moves automatically when transducer moves. The position of the transducer is detected by the electromagnetic system as conventional 3D systems have been used. The ultrasonic images are digitized directly from the video output of the equipment as the signals of the electromagnetic positional system are sent to the personal computer. Both images are displayed simultaneously. Receive is firmly attached to the transducer. Transmitter is a cube 9.6 cm on a side, which is positioned under the bed. To correct as the examinee's physique, we calibrated by the preconcerted, four points calibration is used for abdomen. In clinical study they run well and estimated useful to record ultrasound images in the abdomen, neck, breast and gynecological study. In future, we hope this system will be built in the commercialized ultrasound equipments.
|
Report
(4 results)
Research Products
(8 results)
-
[Journal Article] A new three-dimensional automatic bodymarker system for transviginal ultrasonography2005
Author(s)
Kuwata, T, Taniguchi, N, Matsubara, S, Ono, T, Itoh, K, Suzuki, M.
-
Journal Title
Ultrasound Obster Gynecol. 25
Pages: 586-591
Description
「研究成果報告書概要(和文)」より
Related Report
-
[Journal Article] A new three-dimensional automatic bodymarker system for transvaginal ultrasonography.2005
Author(s)
Kuwata, T., Taniguchi, N., Matsubara, S., Ono, T., Itoh, K., Suzuki, M.
-
Journal Title
Ultrasound Obstet Gynecol. 25
Pages: 586-591
Description
「研究成果報告書概要(欧文)」より
Related Report
-
-
[Journal Article] Automatic virtual transducer locating system to assist interpreting ultrasound imaging2003
Author(s)
Taniguchi, N, Kuwata, T, Ono, T, Itoh, K, Omoto, K, Fujii, Y, Ootake, A.
-
Journal Title
J Med Ultrasonics. 30:
Pages: 211-213
NAID
Description
「研究成果報告書概要(和文)」より
Related Report
-
[Journal Article] Automatic virtual transducer locating system to assist interpreting ultrasound imaging.2003
Author(s)
Taniguchi, N., Kuwata, T., Ono, T., Itoh, K., Omoto, K., Fujii, Y., Ootake, A.
-
Journal Title
J Med Ultrasonics 30
Pages: 211-216
NAID
Description
「研究成果報告書概要(欧文)」より
Related Report
-
-
-