Investigation of Characteristics of Stack Effects Dependent on Arrangement of Void Spaces

Research Project

Project/Area Number 15560511
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Architectural environment/equipment
Research InstitutionUtsunomiya University

Principal Investigator

KOHRI Kimiko  Utsunomiya University, Graduate School of Engineering, Associate Professor, 大学院・工学研究科, 助教授 (20153504)

Project Period (FY) 2003 – 2004
Project Status Completed (Fiscal Year 2004)
Budget Amount *help
¥3,600,000 (Direct Cost: ¥3,600,000)
Fiscal Year 2004: ¥600,000 (Direct Cost: ¥600,000)
Fiscal Year 2003: ¥3,000,000 (Direct Cost: ¥3,000,000)
Keywordsstack effect / void space / natural ventilation / outside air rate coming into a building / entorance
Research Abstract

1.Effect analysis of natural ventilation utilizing void spaces
(1)Effects of natural ventilation are measured in an office building where spaces are ventilated by opening outside air inlets on every floor and outlets at the top of stairwell. It is found that air change rate due to natural ventilation is one to two cycles per hour through the measurement of concentration of the tracer gas as well as the measurement of air velocity and pressure difference at the outside air inlets.
(2)Air movement through the measured whole building were simulated solving the equations of air flow rate balance. The air change rate due to natural ventilation with opening area of 2m^2 on every floor can be expected to be seven cycles per hour.
2.Simulation of outside air flow rate coming into high-rise atrium buildings
An estimation method of average effective opening area at entrance doors affected by number of persons passing through the doors is proposed and the relationships between entrance effective opening area and outside air rate coming through entrance in five atrium buildings are clarified through simulations.

Report

(3 results)
  • 2004 Annual Research Report   Final Research Report Summary
  • 2003 Annual Research Report
  • Research Products

    (11 results)

All 2005 2004 2003 Other

All Journal Article (10 results) Publications (1 results)

  • [Journal Article] 自然換気併用ハイブリッド空調を行うオフィスビルの煙突効果と自然換気量2005

    • Author(s)
      石野久彌, 郡公子, 永田明寛, 長井達夫, 佐藤豊, 尾形拓志他
    • Journal Title

      IBPSA-Japan講演論文集

      Pages: 119-124

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] 自然換気併用ハイブリッド空調を行うオフィスビルの煙突効果と自然換気量2005

    • Author(s)
      石野久彌, 郡公子, 永田明寛, 長井達夫, 佐藤豊, 尾形拓志, 植田浩文, 岡克己, 水出喜太郎
    • Journal Title

      IBPSA-Japan講演論文集

      Pages: 119-124

    • Related Report
      2004 Annual Research Report
  • [Journal Article] エントランス扉の開口面積と外気侵入量に関する研究 第4報アトリウム建築のエントランス開口面と外気侵入量の関係2004

    • Author(s)
      師岡淳, 郡公子, 石野久彌
    • Journal Title

      日本建築学会大会学術講演梗概集 D-2

      Pages: 1335-1336

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] A Study on Characteristics of Outdoor Airflow Rate through Entrances in High-Rise Atrium Buildings Part 3 Influence Analysis by Improvement of a Building Models and the Differences in the Number of Stories2004

    • Author(s)
      K.Kohri, E.Kitahara
    • Journal Title

      Technical Papers of Annual Meeting SHASE

      Pages: 257-2600

    • NAID

      110009750856

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] エントランス扉の開口面積と外気侵入量に関する研究 第4報 アトリウム建築のエントランス開口面積と外気侵入量の関係2004

    • Author(s)
      師岡淳, 郡公子, 石野久彌
    • Journal Title

      日本建築学会大会学術講演梗概集 D-2

      Pages: 1335-1336

    • Related Report
      2004 Annual Research Report
  • [Journal Article] アトリウムをもつ高層ビルのエントランス外気侵入特性に関する研究(第3報)建物モデルの改良と皆数の違いの影響解析2003

    • Author(s)
      郡公子, 北原悦史
    • Journal Title

      空気調和・衛生工学会学術講演会講演論文集

      Pages: 257-260

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] A Study on an Estimation Method of the Effective Opening Area of Entrance Doors and Winter Airflow Rate into Atrium Buildings2003

    • Author(s)
      K.Kohri
    • Journal Title

      Proceedings of Eighth International IBPSA Conference

      Pages: 665-671

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] A Study on an Estimation Method of the Effective Opening Area of Entrance Doors and Winter Air flow Rate into Atrium Buildings2003

    • Author(s)
      K.Kohri
    • Journal Title

      Proceedings of Eight International IBPSA Conference

      Pages: 665-671

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] A Study on the Opening Area of Entrance Doors and the Quantity of Outdoor Air Infiltration, Part 4 Relationship between Entrance Opening Area and Outdoor Airflow Rate in Atrium Buildings

    • Author(s)
      A.Morook, K.Kohri, H.Ishio
    • Journal Title

      Summaries of Technical Papers of Annual Meeting AIJ

      Pages: 1335-1336

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Stack Effects and Natural Ventilation Rate in an Office Building with a Hybrid Air-Conditioning System Utilizing Natural Ventilation

    • Author(s)
      H.Ishino, K.Kohri et al.
    • Journal Title

      Technical Papers of Annual Meeting of IBPS A-Japan

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Publications] 郡公子: "アトリウムをもつ高層ビルのエントランス外気侵入特性に関する研究(第3報)建物モデルの改良と階数の違いの影響解析"空気調和・衛生工学会学術講演会講演論文集. 257-260 (2003)

    • Related Report
      2003 Annual Research Report

URL: 